• a . <br /> FLOORS ` <br /> HOLD-DOWN OR SIMILAR <br /> TENSION DEVICE <br /> FLOOR SHEATHING NAILING AT <br /> 6"MAXIMUM ON CENTER TO <br /> JOIST WITH HOLD-DOWN <br /> _ <br /> Z + + + L + + + <br /> + + + + <br /> I 1\ <br /> FLOOR JOIST DECK JOIST <br /> For SI: 1 inch=25.4 mm. <br /> FIGURE 507.2.3(1) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> SHEATHING <br /> NOTE: SIDING <br /> THIS DETAIL IS APPLICABLE FLASHING FOR <br /> WHERE FLOOR JOISTS ARE lii <br /> WATER TIGHTNESS <br /> PARALLEL TO DECK JOISTS. <br /> DECKING <br /> in <br /> V....,I !: ! APPROVED JOIST HANGERS ' <br /> 2"MIN. 11 <br /> Ii2x LEDGER WITH FASTENERS <br /> ' I1'i�b 4.11111...i IN ACCORDANCE WITH TABLE R507.2 <br /> ■ IIMO <br /> rum <br /> HOLD-DOWN DEVICE MIN 750 LB.CAPACITY <br /> FLOOR JOISTSill AT 4 LOCATIONS, EVENLY DISTRIBUTED <br /> ALONG DECK AND ONE WITHIN 2"OF EACH <br /> END OF THE LEDGER. HOLD-DOWN DEVICES <br /> SHALL FULLY ENGAGE DECK JOIST PER <br /> HOLD-DOWN MANUFACTURER. <br /> A FULLY THREADED 3/8"DIAMETER LAG <br /> SCREW PREDRILLED W/MIN.3"PENETRATION <br /> TO CENTER OF TOP PLATE,STUDS,OR HEADER. <br /> For SI:1 inch=25.4 mm,1 foot=304.8 mm. <br /> FIGURE R507.2.3(2) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> 152 2015 INTERNATIONAL RESIDENTIAL CODE® 1 0 1 ri <br />