• i <br /> Code Compliance Research Report CCRR-1043 Page 5 of 8 <br /> 6.3 Research Reports for evaluation of data in accordance 8.0 OTHER CODES <br /> with ICC-ES Acceptance Criteria for Fire-protective Coatings <br /> Applied to Spray-applied Foam Plastic Insulation Installed This section does not apply. <br /> without a Code-prescribed Thermal Barrier (AC456), dated <br /> October 2015. 9.0 CODE COMPLIANCE RESEARCH REPORT USE <br /> 6.4 Data in accordance with the ICC-ES Acceptance Criteria 9.1 Approval of building products and/or materials can only <br /> for Foam Plastic Sheathing Panels used as Water-Resistive be granted by a building official having legal authority in the <br /> Barriers(AC71),approved February 2003, editorially revised specific jurisdiction where approval is sought. <br /> January 2016. <br /> 9.2 Code Compliance Research Reports shall not be used in <br /> 6.5 Intertek Listing Report "Gaco F1850 Spray-Applied any manner that implies an endorsement of the product by <br /> Polyurethane Foam Insulation". Intertek. <br /> 6.6 Priest&Associates Consulting Letter Report No.10318B, 9.3 Reference to https://bpdirectory.intertek.com is <br /> dated July 22,2015. recommended to ascertain the current version and status of <br /> this report. <br /> 7.0 IDENTIFICATION <br /> The A and B components of the insulation are identified with <br /> the manufacturer's name (Firestone Building Products), <br /> address and telephone number, the product name (Gaco <br /> F1850), use instructions, the flame spread and smoke- <br /> development indices, the lot number, the Intertek Mark, and <br /> the Code Compliance Research Report number(CCRR-1043). <br /> This Code Compliance Research Report("Report")is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and <br /> its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to <br /> the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Report.Only the Client is authorized to permit <br /> copying or distribution of this Report and then only in its entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and <br /> understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the <br /> subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and <br /> this Report does not represent authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or <br /> advertisement of the tested material,product or service must first be approved in writing by Intertek. <br /> 545 E.Algonquin Road •Arlington Heights• Illinois• 60005 <br /> intertek.com/building <br /> Intertek PCA-101 <br /> Version:21 December 2017 SFT-CCRR-OP-40b <br />