Laserfiche WebLink
• <br /> ELECTRICAL GROUNDING SPECIFICATIONS (I) <br /> T1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF ,1'THE NATIONAL ELECTRICAL CODE CURRENTLY IN ,yLANDLORD SIGNATUREo'�_JURISDICTION. <br /> _.( 72. ALL GROUNDING DEVICES SHALL BE U.L.LISTED �7FOR THEIR INTENDED USE.3. GROUND WIRES SHALL BE TINNED#2 AWG BARE <br /> SOLID COPPER UNLESS OTHERWISE NOTED.4. CONNECTIONSOFALLGROUNDWIRESTOTHEIGROUND RING SHALL BE EXOTHERMIC <br /> • <br /> (CAD-WELDED),UNLESS OTHERWISE NOTED.ANO G�� <br /> SHALL BE INSTALLED IN ACCORDANCE WITHL:,�1MANUFACTURERS RECOMMENDATIONS AND ' YYY .11.202(� <br /> T-MOBILE WIRELESS BROADBAND STANDARDS. _ ❑ <br /> NEW#B AWG FROM NEW JUNCTION ' IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY <br /> 5. GROUNDING CONDUCTORS SHALL BE ROUTED ' <br /> ALONG THE SHORTEST AND STRAIGHTEST PATH ❑ ®BOX TO(El GROUND BAR(TYP.) O '! _ <br /> POSSIBLE.WHEN REQUIRED,GROUND LEADS or •'. <br /> " ARE ACTING UNDER THE,TO ALTERION <br /> OF A LICENSED <br /> •�I L +I I » PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. <br /> SHALL BE BENT TOAMINIMUM OF S'RADIUS. u U L ❑ <br /> (E)GROUND BAR(FIELD <br /> 6. WHERE GROUND WIRES ARE ROUTED FROM ANY VIY VERIFY LOCATION)(TYP) \ IA'� • . • <br /> CONNECTION ABOVE GRADE TO THE GROUND RING. 0 \ "( ■ ■•Mobile. <br /> INSTALL WIRE IN 3/4"HEAVY WALL LIQUID TIGHT © NEW MECHANICAL LUG G—G G-• <br /> FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5' IlW CONNECTION(TYP.) ❑ <br /> BELOW GRADE AND SEAL THE TOP WITH SILICONE <br /> SEALANT III--■" r 19807 NORTH CREEK PARKWAY NORTH <br /> 0 BOTHELL,WA 98011 <br /> 7. ALL GROUND BARS SHALL BE TINNED,1/4"COPPER, , <br /> ❑SECTOR BARS 2",COLLECTOR AND MGB BARS 4", • <br /> OF SUFFICIENT LENGTH TO ACCOMMODATE ALL <br /> REQUIRED CONNECTIONS WITHOUT DOUBLING ❑ / `, `\1 Iy�n AM <br /> LUGS.AND EACH INSTALLED WITH ISOLATORS. ' ,! / - \A $r11,101/,m/ /1�OAlatel` <br /> WHEN CONNECTING GROUND BARS(WITHIN 10 • I ❑ off/) Y s <br /> FEET OF GRADE)DIRECTLY TO THE GROUND RING, NEW#6 GROUND LEAD FROM NEW PNW MARKET OFFICE <br /> 2 EA#2 SOLID DOWNLEADS SHALL BE CAD-WELDED <br /> TO THE GROUND BAR,1 AT EACH OPPOSITE ❑ CABINET TO EXISTING GROUND BAR O 9725 3RD AVENUE NE,STE.410 <br /> BOTTOM CORNER.AND EACH SHALL RUN IN 3/4" (TwP•1 <br /> HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT ❑ SEATTLE,WA 98115 <br /> FROM GROUND BAR DOWN TO THE GROUND RING. NEW#e AWG FROM(1)ROUTER(CSR IXRE), ink <br /> WHEN CONNECTING SECTOR GROUND BARS, ❑ (2)ASIK,(2)ASIB,(4)ABIL,(3)ABIC,(3)ABIA, <br /> DAISY-CHAIN THE GROUND BARS AND RUN 1 EA#2 ni (2)AMIA,&(2)VOLTAGE BOOSTERS; <br /> AWG STRANDED COPPER WIRE WITH THWN — I RELOCATED EXISTING(1)ESMB&(1)FSMF ❑ gqr�INSULATION FROM THE MIDDLE GROUND BAR TO TO EXISTING GROUND BAR(TYP.) .,;ill V 1Cig tAssociateS <br /> THE GROUND RING AND CAD-WELD TO THE RING. _ <br /> AI AI NEW#2 AWG GROUND LEAD TO <br /> 6. WHEN ATTACHING STRANDED GROUND LEADS TO ��EXISTING GROUND RING(TYP.) ❑ ❑ Eh 0- ❑ ❑ 0 0 0 0 0 0 0 0 0 <br /> 0 ARCHITECTURE&ENGINEERING <br /> THE GROUND BARS,2 HOLE COMPRESSION LUGS 2667 CAMINO DEL RIO SOUTH,STE.205 <br /> SHALL BE USED,PROTECT WITH WEATHERPROOF <br /> SAN DIEGO,CA 92108 , <br /> HEAT SHRINK AND WITH A THIN COAT OF"KOPR <br /> SHIELD"OR EQUIVALENT PROPERLY APPLIED AND .. <br /> ATTACHED ONLY WITH STAINLESS STEEL <br /> HARDWARE. <br /> 9. WHEN GROUNDING EQUIPMENT ENCLOSURES, <br /> PANELS,FRAMES,AND OTHER METAL APPARATUS, <br /> A#S AWG STRANDED COPPER WIRE WITH THWN SCALE <br /> INSULATION SHALL BE ATTACHED UTILIZING A 2 EQUIPMENT GROUNDING N.T.S. 2 <br /> HOLE COMPRESSION TYPE LUG,PROTECTED WITH 0 10/90/2020 ANCHOR.D00 FOR 100%CD RNS <br /> WEATHERPROOF HEAT A CLEAN AND CORROSION <br /> FREE METALLIC SURFACE UTILIZING STAINLESS <br /> A 08/05/2020 ANCHORALT00 FOR 9016CD RKS <br /> STEEL SELF-TAPPING SCREWS AS NOTED IN NOTE REV DATE DESCRIPTION BY <br /> 10 BELOW. <br /> 10. PREPARE ALL BONDING SURFACES FOR GROUND <br /> CONNECTIONS BY REMOVING ANY AND ALL PAINT <br /> AND CORROSION TO SHINY METAL FOLLOWING S E 01601 B <br /> CAD-WELDED CONNECTIONS TO NON-COPPER <br /> tu <br /> SURFACES,APPLY ONE COAT OF ANY <br /> N EQUIVALENT. <br /> PAINT,"COLD GALV"OR GRAND AVE/ <br /> F EQUIVALENT. <br /> i 11. GROUND RODS SHALL BE COPPER-CLAD STEEL <br /> w5/8'X10',SPACED NO LESS THAN 10'ON CENTER. n in S N O-P U D/ KA N E <br /> O 12. ALL GROUND SYSTEM CONDUCTORS AND r o <br /> CONDUITS SHALL BE SECURED UTILIZING ONLY <br /> z NONMETALLIC,NON-CONDUCTIVE,UV RATED I NEW#BAWGFROMANTENNATO© 4330 RUCKER AVE <br /> CLAMPS,BRACKET,AND OR SUPPORTS. <br /> K (E)SECTOR GROUND BAR(TYP.) <br /> 0 <br /> D 13. WHEN REQUIRED,THE CONTRACTOR SHALL c III VP EVERETT,WA 98203 <br /> UJ <br /> ENGAGE THE SERVICES OF AN INDEPENDENT \ . Imo\ / NEW#6 AWG FROMPENDANTTO WOOD POLE <br /> a• TESTING FIRM TO VERIFY,UTILIZING A MEGGER \` / (E)SECTOR GROUND BAR(7YP.JWV <br /> TEST,THAT THE RESISTANCE TO EARTH OF THE G. _ ) <br /> NEW GROUND SYSTEM IS EQUAL TO OR LESS THAN 7-9 / \ V/ NEW#6 AWG FROM AHLOA, irk <br /> 0 5(OHMS).A COPY OF THE COMPLETE TESTING D� 0_`'J /�/,—� AHFIG,&TMA TO(E)SECTOR <br /> a REPORT SHALL SE PROVIDED TO THE T-MOBILE q/ 9� Jcf"$ 20. GROUND BAR(TYP.) <br /> • REPRESENTATIVE. �-J��' <br /> - ____ <br /> H 14. ALL MATERIALS AND HARDWARE SHALL BR ,/•' �� / �L�'7 �^,���\_�9 <br /> i INSTALLED IN A WORKMAN-LIKE MANNER IN `.I� -„e,. \\' �� <br /> 52 ACCORDANCE WITH MANUFACTURER'S -' ► <br /> �. 9 <br /> D RECOMMENDATIONS,AND DEFINED IN NFPA-90 AND 10 ;� <br /> • APPROVED BY AH,J, - �0,'`` <br /> v00 /G C NEW MECHANICAL LUG 111111 <br /> LEGEND C \ CONNECTION(TYP.) 11107 <br /> ■ EXOTHERMIC CONNECTION % \0, C (E)SECTOR GROUND BAR Ank <br /> < • MECHANICAL CONNECTION \\ (FIELD VERIFY LOCATION) sTAMP <br /> C DEPARTMENT FOR BUILDINGCTION ALCONSIRUCTION <br /> C / (TYP) ® DEPARTMENT FOR IMIDUSE <br /> U EQUIPMENT GROUND BAR <br /> ANTENNA GROUND BAR(AS REQUIRED) <br /> \0 SHEET TITLE <br /> f IIf— #2 AWG GROUND LEAD(AS REQUIRED) GROUNDING <br /> U PLANS <br /> O NOTE: I <br /> b• 1. CONTRACTOR TO REPLACE ALL MISSING GROUND BARS <br /> 2 AND GROUNDING CONNECTIONS AS REQUIRED. •®� SHEET NUMBER <br /> VJ <br /> 0 <br /> NOTES & LEGEND SCALE ANTENNA GROUNDING SCALE <br /> Lu <br /> G- 1 <br /> N.T.S. N.T.S. <br />