Laserfiche WebLink
••' SHKSARCHITFCTS <br /> VIJGEN RESIDENCE i <br /> 050 h3&n 5t f -- -�,1�'' Sasnle.WA 98103 <br /> ABBREVIATIONS DRAFTING SYMBOLS ` � _ .ZOB 6k59�5 ac's <br /> 8 AND GA GAUGE R or HAD RADIUS f <br /> - n - <br /> I ANGLE GALV GALVANIZED RB RESILIENT BASE �' SIM l`- ,v�+wTF c' F. <br /> @ AT GB GRAB BAR RCP REFLECTED CEIUNG PLAN 4®), WALLSECTIEIN 'j ,.^,} - 5156 REGISTERED <br /> 0 DIAMETER GC GENERAL CONTRACTOR RD ROOF DRAIN I _ ARC TECT <br /> • POUND OR NUMBER GL GLASS REF REFERENCE �M ` <br /> (E) EXISTING GLB GLU-LAM BEAM REFF REFRIGERATOR <br /> c. CENTERLINE ONE GROUND REINF REINFORCED SNA ``. c - •JONATAN H, <br /> R PROPERTY LINE GR GRADE RELOC RELOCATE BLDG SECTION �. STAiF OF <br /> GRID ROUTED REDO REQUIRED :1; ` f' - WA$HI Gfi <br /> A.B. ANCHOR BOLT GWB GYPSUM WALL BOARD RES RESILIENT - o <br /> - <br /> ABV ABOVE RM ROOM t t <br /> AC AIR CONDITIONING HE HOSE BIBB RO ROUGH OPENING 1 `` .4 a1 "`"' • <br /> "" - <br /> ACT ACOUSTIC CEILING TILE HC HANDICAP RV ROOF VENT { • - I ACU AIR CONDITION UNIT HCMU HOLLOW CLAY MASONRY UNIT RI RAIN WATER LEADER - <br /> AOJ ADJUSTABLE HDWO HARDWOOD 1 1 EXTERIOR ELEVATION ,1 \ <br /> AFF ABOVE FINISHED FLOOR HDWE HARDWARE S SOURI 'R 1 I occ - <br /> HT HEIGHT SA SMOKE ALARM .1 ____ � <br /> ALUM ALUMINUM HM HOLLOW META A1T ALTERNATESC SOLID CRE 1 �• I - <br /> SCHED SCHEDULE 1 , y - <br /> APPRO% APPROXIMATELY HR HOUR SECT SECTION 1 X <br /> ARCH ARCHITECT.ARCHITECTURAL NORIZ HORIZONTAL SG SAFETY GLASS ,.�c�:R K+R - <br /> BLOG BUILDING I.D. INSIDE DIAMETER SIMM SIMILAR 1 1 INTERIOR ELEVATION p`1 • - <br /> BLW BELOW INSUL INSULATION SPEC SPECIFICATION \ <br /> I _ <br /> BM BEAM TNT INTERIOR SO SQUARE 1 , <br /> 111 <br /> B.O. BOTTOM OF S.S. STAINLESS STEEL ; - <br /> BRS BACKER ROD&SEALANT JAN JANITOR STA STATION <br /> JT JOINT STD STANDARD Ank Sal - <br /> CO CATCH BASIN SR STEEL DETAIL �` 1 l 1 - <br /> CEO CEMENT BACKER BOARD KIT KITCHEN SIN STAINlair 1 111 <br /> CEM CEMENT STOR STORAGE 11 ` \ I <br /> G CONTROL JOINT LAB LABORATORY STRUT STRUCTURE ` _ <br /> CL CENTERLINE SOU SLAB ON GRADE r_ I - <br /> LANLEO LAMINATE \ , � 'F <br /> CLG CEILING SUSP SUSPENDED WT <br /> lAY LAVATORY NORTH ARROW <br /> CLA CLEAR LOR LOCKER SYM SYMMETRICAL � r <br /> CO CLEAN COL COLUMN LOC LOCATE E t /. / - <br /> CONC CONCRETE LT LIGHT LIMP TEMPERED ,-�� - - <br /> LVL LAMINATED VENEER LUMBER <br /> CONE CONDITION TOG TONGUE 8 GROOVE O GRID HEAD -� <br /> CONT CONTINUOUS TEL TELEPHONE <br /> CPT CARPET M MEWS TER TERRAllO <br /> MAIL MATERIAL <br /> CT CERAMIC TILE THE THICK PLAN <br /> CTR CENTER MAX MAXIMUM T.O. TOP OF ROOM NAME ROOM TAG O SITE PLAN <br /> MC MEDICINE CABINET TS TUBE STEEL 101 1 1'=20-0' -- <br /> MECH MECHANICAL TV TELEVISION <br /> DBE DOUBLE MEMB MEMBRANE TYP TYPICAL 0WINDOW 8 <br /> DEMO DEMOLISH MFR MANUFACTURER <br /> OF DRINKING FOUNTAIN MIN MINIMUM STOREFRONT TAG <br /> SIB DIAMETER MIN MIRROR UL UNDERWRITERS'LABORATORIES <br /> GENERAL NOTES PROJECT INFORMATION APPLICABLE CODES <br /> RIFF DIFFUSER MISC MISCELLANEOUS UNS UNLESS NOTED OTHERWISE 1i ROOF TAG 1. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL NOTES AND SYMBOLS. 2015 INTERNATIONAL BUILDING CODE <br /> DIM DIMENSION MH MANHOLE UM UTILITY PROJECT OWNER: 2015 UNIFORM PLUMBING CODE <br /> DISP DISPENSER MO MASONRY OPENING 2. MATERIALS,ASSEMBLIES AND NOTED NO.N ARE NEW UNLESS OTHERWISE NOTED. <br /> RE CODE <br /> ON DOWN MTO MOUNTED VCT VINYL COMPOSITION TILE 1i WALL TAG 3. CONTRACTOR SHALL VERIFY CRINIONS.NOTIFY THE ARCHITECT OF ANY CONDITIONS INCONSISTENT WITH THE INTENT OF THE RAWING3 49 9 AND23A AVE A VIJGEN 2015 WAS2015 HINGTON STATEATIONAL 1 ENERGY CODE <br /> DR DOOR MIL METAL VERT VERTICAL PRIOR TO STARTING OR CONTINUING WORK IN THE AREA CONCERNED. EVERETT WA 98203 <br /> OS DOWNSPOUT MULL MULLION VEST VESTIBULE <br /> on. DETAIL VIF VERIFY IN FIELD I 1i I ROR TAG CODE: - <br /> OW DISHWASHER VTR VENT THRU ROOF 1. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND LOCAL BUILDING REQUIREMENTS,WHICH INCLUDE THE MOST CURRENT EDITIONS OF PROJECT MANAGER: <br /> N NORTH THE INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS,INTERNATIONAL MECHANICAL CODE(IMC),NATIONAL ELECTRICAL CODE(NEC), CASSIDY➢MMERMAN DESIGN TEAM <br /> NA NOT APPLICABLE DOOR TAG INTERNATIONAL FIRE CODE(NC),AND WASHINGTON STATE ENERGY CODE(WEC). 1050 N 38TH ST <br /> E EAST NIC NOT IN CONTRACT W WEST 101 2. PROVIDE FIREBLOCKS AND DRAFTSTOPS PER IBC. SEATTLE WA 98103 ARCHITECT: <br /> EA EACH NOM NOMINAL W/ WITH SHKS ARCHITECTS <br /> ECS EXTERIOR COMPOSITE SIDING OUTS NOT TO SCALE WC WATER CLOSET RAZNAT: PROJECT ADDRESS: 1050 NORTH 38TH ST <br /> EF EXHAUST FAN NO NOTATED WO WOOD 1. HAZARDOUS MATERIAL REMOVAL 8 DISPOSAL:BEFORE BEGINNING ANY DEMOLITION OR OTHER WORK COMPLY WITH DOCUMENTS PREPARED BY 4918 23RD AVENUE WEST SEATTLE,WA 98103 - <br /> EJ EXPANSION JOINT WF WIDE FLANGE THE GAMER'S HAZARDOUS MATERIALS CONSULTANT.THIS APPLIES TO DEMOLITION,DISPOSAL AND CONSTRUCTION OPERATIONS ASSOCIATED EVERETT,WASHINGTON 98203 TEL:206.224.3323 <br /> ELELEVATION WIN WINDOW 0 KE,NOTE WITH THE PROJECT.THE CONTRACTOR WILL SUSPEND WORK IMMEDIATELY AND NOTIFY THE OWNER IF MATERIALS SUSPECTED OF BEING CONTACT:CASSIDY NMMERMAN - <br /> ELFC ELECTRICAL DA OVERALL W/O WITHOUT HAZARDOUS.AND NOT PREVIOUSLY IDENTIFIED.ARE ENCOUNTERED IN THE COURSE OF THE CONTRACTORS WORK. SCOPE DESCRIPTION: EMAIL:CESAIJW@BYHS&CTOECIB.com <br /> OBS OBSCUREINTERIOR RENOVATION INCLUDING REMOVAL OF PARTIAL HEIGHT WALLS <br /> ELEV ELEVATOR WON WALK OFF MAT , <br /> B.C. ON CENTER NAME� OEMOLITIN: AND RECONFIGURATION OF STAIR. VIJGEN <br /> EMERG EMERGENCY 0.0. OUTSIDE DIAMETER RM WOMEN'S ELEvA''lon r ELEVATION - VIJGEN <br /> EQ EQUAL WP WATERPROOFING 1. WHERE ITEMS ARE INDICATED ON PLANS TO BE DEMOLISHED,IT SHALL MEAN THE COMPLETE REMOVAL AND DISPOSAL OF THE ITEM INDICATED C <br /> FICE <br /> E%P EXPANSION OFF <br /> ffNE OPENINGF WR WATER RESISTANT UNLESS OTHERWISE NOTED.CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE HAZARDOUS MATERIALS ABATEMENT,ARCHRECTURALAND RESIDENCE <br /> DPP OPPOSITE WSCT WAINSCOT DICE STRUCTURAL DRAWINGS AND SP:CIFICATIONSFOR CUTTO:S AND PATCHING WORK. ZONING ANALYSIS SHEET INDEX <br /> FBP FIBER BOARD PANEL WT WEIGHT T.O.XXX SPOT ELEVATION <br /> FD FLOOR DRAIN PC PRECAST CONCRETE DIMENSIONS: <br /> FE FIRE EXTINGUISHER PL KLATE 1. 00 NOT SCALE DRAWINGS. A0.0 COVER SHEET <br /> FF FINISH FLOOR PUS PLASTER 2. VERIFY DIMENSIONS SHOWN ON DRAWINGS.USE ONLY DIMENSIONS INDICATED.PRIOR TO STARTING OR CONTINUING WORK NOTIFY ARCHITECT 1. PROJECT ADDRESS: PERMIT <br /> FN FIRE HYDRANT PLY PLYWOOD E- CENTERLINE OF DISCREPANCIES OR CUNDmGNS INCONSISTENT WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS. EVERETT, AVENUE WEST <br /> E A8203 A2.0 LOWER LEVEL FLOOR PANS - <br /> RN FINISH PIMA PLASTIC LAMINATE 3. DIMENSIONS ARE TO FACE OF CONCRETE,FACE OF MASONRY.OR FACE OF STUD,UNLESS OTHERWISE NOTED. A2.1 MAIN FLOOR PLANS DRAWINGS <br /> FLIT FLOOR DINT PAINT 4. FINISHED SURFACE OF INFILL OR EXTENSIONS OF EXISTING PARTITIONS SHALL ALIGN WITH ADJACENT EXISTING SURFACES UNLESS OTHERWISE 2, pBRCEI NUMBER A3.1 BUILDING SECTIONS <br /> F.O. FACE OFNOTED. 4918 23RD AVENUE WEST <br /> POC POINT0F CONNECTION - -Q. - PROPERTY LINE 5. VERTICAL DIMENSIONS ARE MEASURED FROM STRUCTURAL SLAB,TOP OF STEEL OR TOP OF SHEATHING,UNLESS NOTED OTHERWISE. 00644500000600 - EVERETT,WA 98203 <br /> FOIL FURNISHED BY OWNER, PR PAIRB. DOORS NOT LOCATED BY DIMENSION ON PANS SHALL BE SIX INCHES FROM FACE OF ADJOINING PARTITION TO HINGE EDGE OF DOOR OPENING. <br /> INSTALL BY CONTRACTOR PSL PARALLEL STRAND LUMBER3. LEGAL DESCRIPTION: - <br /> F010 FURNISHED BY OWNER PT PRESSURE TREATED _ XOIX XXX PROVIDETHERW SENIOTE,NOTIFY CLEAR FROM CT IF OF REQUIRED <br /> ARANC S ARE NUT OTHER AVAILABLE. <br /> OBSTRUCTION TO JAMB EDGE OF DOOR OPENING,UNLESS GRANADA SEAVIEW ESTATES DIV.NO.1 BLK 000 _ <br /> INSTALL BY OWNER PTN PARTITION FLOOR TRANSITION OTHERWISE NOTED. ARCHITECT IF REQUIRED CLEARANCES NOT AVAILABLE. 0-00-LOT 6 SUBJ TO ESE PXD E.GEN TEL <br /> FR FIRE RESISTANT COORDINATION: - <br /> FS FLOOR SINK 1Q REVISION 1. COORDINATE ALL OPERATIONS WITH OWNER,SUCH AS AREAS USED FOR MATERIAL STORAGE,ACCESS TO AND FROM THE SITE,TIMING OF WORK 4. LOT AREA 0.23 ACRE Drawn by: CZ <br /> FT FEET OT QUARRY TILE DESCRIPTION AND REQUIREMENTS OF NOISE ORDINANCE.INSTALL DUST AND NOISE BARRIERS AS REQUIRED TO PROTECT EXISTING ADJACENT BUILDINGS AND <br /> OCCUPANTS AND TO MAINTAIN AN ENVIRONMENT SUITABLE TO PERMIT CONTINUED OCCUPANCY OF SUBJECT AND ADJACENT BUILDINGS. 5. ZONE:R-S - Checked: C2 <br /> -'11 BREAKLINE 2. REVIEW DEMOLITION DRAWINGS.PATCH AND REPAIR ALL EXISTING SURFACES AFFECTED BY DEMOLITION WORK. pate: 1W76XT9 <br /> 3. REVIEW ARCHITECTURAL AND STRUCTURAL DRAWINGS AND PROVIDE ROUGH-INS THROUGH SLABS,BEAMS,WALLS.CEILINGS,AND ROOFS FOR 6. CURRENT USE:RESIDENTIAL - <br /> MATERIAL SYMBOLS 1> DIMENSION POINT DUCTS,PIKS.COORDINATE WITH INSTALLATION REQUIREMENTS.S,JUNCTION BOXES,CABINETS AND <br /> AND REPAIREXISTING ENT.VERIFY SURFACES AS NECESSARY TO COMPLETE WORK.D LOCATION BEFORE PROCEEDING WITH WORK 7. YEAR BUILT:1978 - Scale: As indicated <br /> 4. COORDINATE AND PROVIDE REQUIRED PENETRATIONS AND PATCHING WITH INDIVIDUAL SUBCONTRACTORS TO SUR NEW WORK - RBAADnS: <br /> S. (El BLDG AREA:3,796 SF <br /> 5. CONTACTOR TO OBTAIN AND VERIFY ROUGH-IN DIMENSION REQUIREMENTS FOR CABINETRY,EQUIPMENT,ACCESSORIES AND THE LINE ND. Dale Remy <br /> DETAIL BORDER REMODEL AREA:70 SF BASEMENT - <br /> - <br /> _ INCLUDING THOSE DESIGNATED FOIC AND F010.CONTRACTOR TO PROVIDE BACKING,BLOCIUNG,SUPPORT AS REQUIRED FOR INSTALLATION. <br /> CONTRACTOR TO COORDINATE POWER,DATA COMMUNICATIONS AND SECURITY REQUIREMENTS FOR FOIC AND F010 EQUIPMENT WHERE 070 SF MAIN FLOOR <br /> GRAVEL CONCRETE(CUT) CONCRETE(SURFACE) SERVICES ARE REQUIRED.INCLUDE STUB OUTS AND CONNECTIONS.VERIFY AND COORDINATE DIMENSIONS OF FOIC AND F010 ITEMS PRIOR TO 340 SF TOTAL REMODEL AREA - <br /> I I PROCEEDING WITH WORK.INCLUDE STUB OUTS FOR FUTURE WORK. - <br /> 6. PIPING,CONDUITS,DUCTS,ETC.SHALL BE CONCEALED IN WALLS,CHASES.ABOVE SUSPENDED CEILINGS,BELOW FLOORS OR BE FURRED-IN IN 9. (El LOT COVERAGE:21%,NO CHANGE <br /> ROOMS WITH EXISTING CEILINGS,UNLESS OTHERWISE NOTED. - <br /> - 7. CAREFULLY COORDINATE ELECTRICAL INSTALLATIONS WITH EXISTING STRUCTURE AND BUILDING SYSTEMS. 10.HT LIMIT:NO CHANGE <br /> EARTH BATT INSULATION -- - RIGID INSULATION 8. "REMOVE'MEANS TO COMPLETELY AND PERMANENRY REMOVE FROM THE PROJECT. <br /> .... 9. REFER TO LIGHTING PLAN AND ELECTRICAL DRAWINGS FOR ELECTRICAL DEVICES AND LOCATIONS.COORDINATE AND REVIEW DEVICE LOCATIONS 11.PARKING QUANTITY:NO CHANGE - <br /> WITH ARCHITECT IN FIELD PRIOR TO ROUGH-IN. <br /> 12.REQUIRED SETBACKS:NO CHANGE <br /> MASONRY PLYWOOD WOOD - <br /> - COVER SHEET <br /> STEEL OMB <br /> \ V. <br /> = A0.0 <br />