My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6311 36TH AVE W AMAZON 2021-12-16
>
Address Records
>
36TH AVE W
>
6311
>
AMAZON
>
6311 36TH AVE W AMAZON 2021-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2021 2:07:32 PM
Creation date
9/15/2021 11:27:49 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6311
Tenant Name
AMAZON
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington Staonergy Code Compliance Forms for Commercial, ad R3 over 3 stories and all R1 /F/� <br />Mechanical Summary MECH-SUM <br />2015 Washington State Energy Code Com fiance Forms for Commercial Buildings including R2 & R3 over 3 stories and all RI Revised January 2017 <br />Project Information <br />Project Title: HBF4 <br />Date 8/21/2020 <br />Applicant Information. Provide contact information for individual who can respond to <br />For Building Dept. Use <br />inquiries about compliance form information provided. <br />Company Name: Evergreen Refrigeration <br />Company Address: 727 South Kenyon St. Seattle, WA 98108 <br />Applicant Name: Alex Burkhart <br />Applicant Phone: 206-763-1744 ext. 247 <br />Project Description <br />❑ New Building ❑ Building Addition Tenant Improvement ❑ System Retrofit ❑ No System Changes <br />Briefly describe mechanical systems in <br />the text box provided <br />Installation of One (1) Makeup Air Unit, One (1) Drop Box Diffuser, One (1) Gas Unit Heater w/ Thermostat, <br />❑ Total Bldg Performance (TBP) <br />Three (3) HVLS Fans w/ Controllers, Three (3) Cage Fans, and Relocation of Existing Grilles/Diffusers. <br />This path includes all mandatory <br />provisions per C401.2 Option 2. <br />MECH-SUM, MECH-CHK, and C407 <br />Energy Analysis forms required. <br />❑ Load calculation summary ❑ MECH-LOAD-CALC Form <br />Design Load Calculations <br />Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or <br />ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable <br />compliance information then the MECH-LOAD-CALC form is not required. <br />El Mechanical Plans ❑ MECH-EQ Forms (TBD) <br />Mechanical Schedules <br />Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, <br />however, include on plans all applicable compliance information listed in MECH-EQ tables. <br />❑ DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupancies) <br />All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does <br />not require space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling is required. <br />Dedicated Outdoor Air <br />❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1) <br />System Requirements and <br />❑ ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception <br />High Efficiency VAV <br />❑ DOAS included in project, although not required (occupancy not office, retail, education, library or fire station) <br />Alternate <br />❑ DOAS related allowances included in project: <br />❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per C402.4.1.4 with 100% of <br />conditioned floor area in building served by DOAS. <br />❑ Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. <br />❑� Project includes HVAC air distribution systems that provide heating and/or cooling <br />If yes, provide a MECH-FANSYS -SUM form. <br />Fan Power <br />❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds Shp. <br />If yes, provide a separate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. <br />Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. <br />❑ Hydronic chilled water ❑ Water -loop heat pump No hydronic systems <br />HVAC Hydronic Systems <br />❑ Hydronic heating water ❑ Geothermal <br />❑ C406.2 More efficient HVAC equipment and fan systems <br />Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat <br />pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than <br />C406 Additional <br />minimum requirements. All stand alone supply, return, and exhaust fans over 1hp must have FEQ> 71 and must be <br />selected within 10 % of maximum total or static pressure. <br />Efficiency Options - <br />❑ C406.6 Dedicated outdoor air system (DOAS) <br />Mechanical <br />Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a <br />manner that does not require space conditioning fan operation. <br />❑ C406.7 Reduced energy in service water heating <br />Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use <br />be provided by heat pump, waste heat recovery or solar water -heating systems. <br />
The URL can be used to link to this page
Your browser does not support the video tag.