Laserfiche WebLink
1 F O R T E MEMBER REPORT main, JBB-02 JOIST BEARING BEAM • PASSED <br />1 piece(s) 5 l�x 9" 24F-V4 DF Glulam <br />0 <br />i <br />Overall Length: 10' 4" <br />10' 4" <br />0 <br />i <br />0 9 <br />All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal. <br />Design Results <br />Actual @ Location <br />Allowed <br />Result <br />LDF <br />Load: Combination (Pattern) <br />Member Reaction (Ibs) <br />2423 @ 1/4" <br />5830 (1.75") <br />Passed (42%) <br />-- <br />1.0 D + 1.0 L (All Spans) <br />Shear(lbs) <br />1997 @ 10 3/4" <br />8149 <br />Passed (25%) <br />1.00 <br />1.0 D + 1.0 L (All Spans) <br />Pos Moment (Ft-Ibs) <br />6121 @ 5' 1 1/8" <br />13838 <br />Passed (44%) <br />1.00 <br />1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in) <br />0.158 @ 5' 1 1/8" <br />0.338 <br />Passed (L/770) <br />1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in) <br />0.202 @ 5' 1 1/8" <br />0.507 <br />Passed (L/602) <br />- <br />1.0 D + 1.0 L (All Spans) <br />Deflection criteria: LL (1-/360) and TL (L/240). <br />Top Edge Bracing (Lu): Top compression edge must be braced at 10' 4" o/c unless detailed otherwise. <br />Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 10' 4" o/c unless detailed otherwise. <br />Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 10' 1 3/4". <br />The effects of positive or negative camber have not been accounted for when calculating deflection. <br />The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. <br />Applicable calculations are based on NDS. <br />supports <br />Bearing Length <br />Loads to Supports (Ibs) <br />Accessories <br />Total <br />Available <br />Required <br />Dead <br />Floor <br />Live <br />Total <br />1 - Column - OF <br />1.75" <br />1.75" <br />1.50" <br />530 <br />1893 <br />2423 <br />Blocking <br />2 - Column - OF <br />3.50" <br />3.50" <br />1.50" <br />545 <br />1947 <br />2492 <br />Blocking <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Loads <br />Location (Side) <br />Tributary <br />Width <br />Dead <br />(0.90) <br />Floor Live <br />(1.00) <br />Comments <br />0 - Self Weight (PLF) <br />0 to 10' 4" <br />N/A <br />11.2 <br />1 - Uniform (PSF) <br />0 to 10' 4" (Top) <br />9' 3 1/2" <br />10.0 <br />40.0 <br />Snow <br />Weyerhaeuser Notes <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br />Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design <br />professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is <br />compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES <br />under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser <br />product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by Forte Software Operator <br />Forte Software Operator Job Notes <br />Ron Button Andrew Shubin (Shutov) <br />Design Lines 8029 57th Ave SW <br />(425) 353-0531 Everett, We. <br />r.button@designiines.com <br />System : Floor <br />Member Type : Drop Beam <br />Building Use : Residential <br />Building Code : IBC 2015 <br />Design Methodology : ASD <br />4 SUSTAINABLE FORESTRY INITIATIVE <br />12/7/2018 10:02:13 AM <br />Forte v5.4, Design Engine: V7.1.1.3 <br />Shubin.4te <br />Page 1 of 1 <br />