�Ev_ <br />STRUCTURAL NOTES <br />1.1 ANY DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE <br />NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT <br />AND THE STRUCTURAL ENGINEER WHO SHALL CORRECT SUCH DISCREPANCY IN <br />WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH <br />DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. THE CONTRACTOR <br />SHALL VERIFY AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR <br />TO PROCEEDING WITH ANY WORK OR FABRICATION. THE CONTRACTOR IS <br />RESPONSIBLE FOR ALL ERECTION BRACING, FORMWORK AND TEMPORARY <br />CONSTRUCTION SHORING. <br />12 BY THE ACT OF SUBMITTING A BID FOR THE PROPOSED CONTRACT, THE <br />CONTRACTOR WARRANTS THAT: <br />12.1 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />(INCLUDING AGENTS AND SUPPLIERS) HAVE CAREFULLY AND <br />THOROUGHLY REVIEWED THE DRAWINGS AND STRUCTURAL NOTES <br />AND HAVE FOUND THEM COMPLETE AND FREE FROM AMBIGUITIES <br />AND SUFFICIENT FOR THE PURPOSE INTENDED. <br />122 THE CONTRACTOR HAS CAREFULLY EXAMINED THE SITE OF THE <br />WORK AND THAT FROM HIS OWN INVESTIGATIONS, HE HAS SATISFIED <br />HIMSELF AS TO THE NATURE AND LOCATION OF THE WORK, AS TO THE <br />CHARACTER QUALM, AND QUANTITIES OF MATERIAL AND <br />DIFFICULTIES TO BE ENCOUNTERED, AS TO THE EXTENT OF <br />EQUIPMENT AND OTHER FACILITIES NEEDED FOR THE PERFORMANCE <br />OF THE WORK AND AS TO THE GENERAL AND LOCAL CONDITIONS, AND <br />OTHER ITEMS WHICH MAY IN ANY AFFECT THE WORK OR ITS <br />PERFORMANCE. <br />12.3 THE CONTRACTOR AND ALL WORKERS HE INTENDS TO USE ARE <br />SKILLED AND EXPERIENCED IN THE TYPE OF CONSTRUCTION <br />REPRESENTED BY THE DRAWINGS AND DOCUMENTS BID UPON. <br />12.4 NEITHER THE CONTRACTOR NOR ANY OF HIS EMPLOYEES, AGENTS, <br />INTENDED SUPPLIERS, OR SUBCONTRACTORS HAVE REUED UPON <br />ANY VERBAL REPRESENTATIONS ALLEGEDLY AUTHORIZED OR <br />UNAUTHORIZED FROM THE OWNER OR HIS EMPLOYEES DR AGENTS, <br />INCLUDING THE ARCHITECT OR ENGINEERS, IN ASSEMBLING THE BID <br />FIGURES. <br />12.5 THE REQUIREMENTS CONTAINED WITHIN THIS SECTION SUPERSEDE <br />REQUIREMENTS AND/OR RECOMMENDATIONS CONTAINED IN THE ASC <br />'CODE OF STANDARD PRACTICE FOR STEEL BUILDING AND BRIDGES', <br />AS WELL AS CASE DOCUMENT 962-D'A GUIDELINE ADDRESSING <br />COORDINATION AND COMPLETENESS OF STRUCTURAL <br />CONSTRUCTION DOCUMENTS' <br />12.6 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />ARE AWARE OF AND ACKNOWLEDGE THAT CLOSE COORDINATION <br />AMONG ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL <br />AND OTHER TRADE DRAWINGS IS REWIRED. <br />12.7 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />SHALL RECDGN12E THAT THE PROJECT CONTRACT DOCUMENTS <br />INCLUDE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND <br />ELECTRICAL AND OTHER TRADE DRAWINGS AND SPECIFICATIONS. <br />128 THE CONTRACTOR AND ALL SUBCONTRACTORS ACKNOWLEDGE THAT <br />CLOSE COORDINATION BETWEEN DISCIPLINES INCLUDED WITHIN THE <br />CONTRACT DOCUMENTS IS NECESSARY. ELEMENTS THAT WILL <br />REQUIRE CLOSE COORDINATION BY THE CONTRACTOR INCLUDE (BUT <br />ARE NOT LIMITED TO): <br />A VERIFICATION OF ALL DIMENSIONS INDICATED ON THE <br />MECHANICAL AND STRUCTURAL DRAWINGS <br />B. DETERMINATION OF ALL ANCHOR LOCATIONS <br />C. DETERMINATION OF TOP OF FOOTING ELEVATIONS, <br />D. MECHANICALIELECTRICAL EQUIPMENT LOCATIONS AND WEIGHTS <br />E. LOCATION AND SIZE OF ALL MECHANICAL/ ELECTRICAL <br />PENETRATIONS THROUGH WALLS AND FLOORS/ ROOFS <br />12.10 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />SHALL MAKE CONSIDERATION FOR, AND INCLUDE MONIES FOR THE <br />ABOVE IN THE PREPARATION OF THEIR BIDS. <br />12.11 THE CONTRACTOR SHALL NOT SCALE THE MECHANICAL AND <br />STRUCTURAL DRAWINGS FOR LOCATIONS OF ELEMENTS NOTED <br />ABOVE. <br />1212 ELECTRONIC COPIES OF THE STRUCTURAL DRAWINGS (PDF5, CAD <br />DRAWINGS OR BIM MODELS) MAY BE PROVIDED TO THE CONTRACTOR <br />FORTHEIRUSE. THESE FILES MAYBE PROVIDED AT THE REQUEST OF <br />THE CONTRACTOR FOR THEIR CONVENIENCE ONLY. THE <br />CONTRACTOR AGREES THAT THESE FILES SHALL NOT SUPERCEDE <br />INFORMATION SHOWN ON THE ORIGINAL BID/ CONSTRUCTION <br />DOCUMENTS. THE CONTRACTOR AGREES TO HOLD THE STRUCTURAL <br />ENGINEER HARMLESS FOR ANY ERRORS OR DISCREPANCIES <br />CONTAINED WITHIN THESE ELECTRONIC FILES. <br />12.13 THE BID FIGURE IS BASED SOLELY UPON THE CONSTRUCTION <br />CONTRACT DOCUMENTS AND PROPERLY ISSUED WRITTEN OR VERBAL <br />REPRESENTATIONS. <br />1.3 EXISTING BUILDING CONDITIONS <br />1.3.1 STRUCTURAL DESIGN IS BASED ON EXISTING FRAMING CONDITIONS <br />OBSERVED AND FIELD MEASURED AND/OR DESCRIBED IN ORIGINAL <br />CONSTRUCTION DRAWINGS. FIELD OBSERVATIONS DURING DESIGN <br />ARE LIMITED TO AREAS OPEN TO VIEW AND ACCESSIBLE. <br />1.32 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING FRAMING <br />CONDITIONS FOR COMPLIANCE WITH THE INFORMATION SHOWN ON <br />THE STRUCTURAL DRAWINGS PRIOR TO DEMOLITION AND <br />CONSTRUCTION. AS -BUILT DEVIATIONS FROM THE INFORMATION <br />SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER <br />PRIOR TO EXECUTION OF WORK IN THE AREAS AFFECTED BY THE <br />DISCREPANCY. <br />1A CODES <br />1.4.1 ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO <br />THE 2012 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND <br />ADOPTED BY THE LOCAL BUILDING AUTHORITY. <br />1.42 ALL REFERENCES TO OTHER CODES, STANDARDS AND <br />SPECIFICATIONS, (ACI, ASTM, ETC.), SHALL BE FOR THE EDITION <br />CURRENTLY REFERENCED BY IBC AS AMENDED AND ADOPTED BY THE <br />LOCAL BUILDING AUTHORITY. <br />1.5 DESIGN CRITERIA <br />1.52 UNIFORM LOADS: <br />LOCATION LIVE LOAD DEAD LOAD <br />ROOF 25 PSF (SNOW? ACTUAL <br />STRUCTURAL 125 PSF ACTUAL <br />SLAB ON GRADE <br />THIS IS NOT A GROUND SNOW LOAD <br />1.5.6 WIND LOADS (PER IBC SECTION 1609 AND ASCE 7 CHAPTERS 26 THRU <br />30k <br />ULTIMATE DESIGN WIND SPEED (V,a): 11O MPH <br />RISK CATEGORY: I <br />WIND EXPOSURE: B <br />ENCLOSED STRUCTURE <br />TOPOGRAPHIC FACTOR 09 1.0 <br />COMPONENTS AND CLADDING: ULTIMATE DESIGN WIND PRESSURES <br />TO BE USED FOR THE DESIGN OF EXTERIOR COMPONENT AND <br />CLADDING MATERIALS IS AS FOLLOWS: <br />ZONE:1 +16.0 A21.8 PSF(10 SQ FT) <br />ZONE2 +16.0 AM.5 PSF(10 SQ FT) <br />ZONE:3 +16.0/-65.0 PSF(10 SQ FT) <br />ZONEA AU1-21.6 PSF(10 SQ FT) <br />ZONES +19.9426.6 PSF (10 SQ FT) <br />1.5.7 SEISMIC LOADS (PER SC SECTION 1613 AND ASCE 7 CHAPTERSS 11 <br />THRU 13). <br />RISK CATEGORY: I <br />SEISMIC IMPORTANCE FACTOR (6): 1.0 <br />S,: 1.441 <br />Si: 0,553 <br />SITE CLASS: D <br />S,rz : 0.961 <br />S' : 0.553 <br />SEISMIC DESIGN CATEGORY: D <br />DESIGN BASE SHEAR 0.154 Wp <br />ANALYSIS PROCEDURE USED: ASCE 13.3.1 <br />NONSTRUCTURAL <br />COMPONENTS <br />1.6 STATEMENT OF SPECIAL INSPECTIONS <br />SEE STATEMENT OF SPECIAL INSPECTION AND TESTING SHEET SO2. <br />1.7 SHOP DRAWINGS <br />1.7.1 SUBMIT SHOP DRAWINGS TO THE ARCHITECT!ENGINEER FOR THE <br />FOLLOWING: <br />A CONCRETE MIX DESIGN SUBMITTALS <br />B. REINFORCINGSTEEL <br />C. STRUCTURAL AND MISCELLANEOUS STEEL INCLUDING WELD <br />INSERTS AND ANCHORS <br />1.7.3 SHOP DRAWING RENEW NOTES <br />A ENGINEER OF RECORD SHALL REVIEW SHOP DRAWINGS FOR <br />GENERAL CONFORMANCE WITH THE PROJECT CONSTRUCTION <br />DOCUMENTS (PLANS AND SPECIFICATIONS). <br />B. ENGINEER OF RECORD REVIEW OF SHOP DRAWINGS SHALL NOT <br />RELIEVE THE GENERAL CONTRACTOR OF THEIR RESPONSIBILITY <br />FOR REVIEW OF THE SHOP DRAWINGS FOR COMPLIANCE NTH <br />THE PROJECT REQUIREMENTS. <br />C. APPROVAL OF THE SHOP DRAWINGS BY THE ENGINEER OF <br />RECORD SHALL NOT BE CONSIDERED AS A GUARANTEE BY THE <br />ENGINEER THAT THE SHOP DRAWINGS COMPLY WITH ALL <br />PROJECT REQUIREMENTS. <br />D. CONCURRENT SHOP DRAWING REVIEW SHALL ONLY BE <br />PERMITTED IF APPROVED BY THE ARCHTTECTIENGINEER OF <br />RECORD PRIOR TO THE START OF SHOP DRAWING REVIEW. <br />1.8 MISCELLANEOUS <br />1.8.1 VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. <br />1.82 VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOORS, ROOF <br />AND WALLS WITH MECHANICAL AND ELECTRICAL DRAWINGS. <br />1.8.3 CONSTRUCTION DETAILS NOT SPECIFICALLY SHOWN ON THE <br />DRAWINGS SHALL FOLLOW SIMILAR DETAILS OF SECTIONS OF THIS <br />PROJECT AS APPROVED BY THE ENGINEER <br />1.8.4 SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR DIMENSIONS AND <br />LOCATIONS OF OPENINGS NOT DIMENSIONED OR SHOWN ON <br />STRUCTURAL PLANS. <br />1.8.5 SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS AND <br />WEIGHTS OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT <br />INCLUDING HOUSEKEEPING PADS. <br />2. SITE PREPARATIONISOIL REMEDIA71ON <br />2.1 SOIL DATA <br />ALLOWABLE SOIL PRESSURE 25DO PSF PER ORIGINAL BUILDING DRAWINGS. <br />ALLOW 33-1f3%INCREASE FOR LOADS FROM WIND OR SEISMIC ORIGIN. <br />22 EXCAVATION <br />EXCAVATE TO DEPTH SHOWN AND TO FIRM UNDISTURBED MATERAL. <br />OVER -EXCAVATIONS SHALL BE BACKFILLED WITH LEAN CONCRETE (Tr-500-1200 <br />PSI) OR STRUCTURAL FILL AT THE CONTRACTOR'S EXPENSE. EXERCISE <br />EXTREME CARE DURING EXCAVATION TO AVOID DAMAGE TO BURIED LINES, <br />TANKS, AND OTHER CONCEALED ITEMS. UPON DISCOVERY, DO NOT PROCEED <br />WITH WORK UNTIL RECEIVING WRITTEN INSTRUCTIONS FROM THE ENGINEER A <br />COMPETENT REPRESENTATIVE OF THE OWNER SHALL INSPECT ALL FOOTING <br />EXCAVATIONS FOR SUITABILITY OF BEARING SURFACES PRIOR TO PLACEMENT <br />OF REINFORCING STEEL. PROVIDE DRAINAGE AS NECESSARY TO AVOID <br />WATERSOFTENIED SUBGRADE. <br />2.3 FILL AND COMPACTION <br />STRUCTURAL FILL OTHER THAN PEA GRAD SHALL BE GRANULAR PLACED IN <br />6-INCH UFTS AND COMPACTED TO AT LEAST 95%OF ITS MAXIMUM DRY DENSITY <br />AS DETERMINED BYASTMD-1567(MODPRDCTOR). PEA GRAVEL FILL SHALL <br />HAVE A MAXIMUM PARTICLE SIZE OF 3.R' DIAMETER <br />3. STRUCTURAL CONCRETE <br />3.1 GENERAL <br />ALL CONCRETE SHALL BE HARD ROCK CONCRETE MEETING THE REQUIREMENTS <br />OF ACI.301,'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS.' <br />PROPORTIONING OF INGREDIENTS FOR EACH CONCRETE MIX SHALL BE BY <br />METHOD 2 OR THE ALTERNATE PROCEDURE GIVEN IN AC1301. PLACE <br />CONCRETE PER ACI-3D4 AND CONFORM TO ACIS04 (306) FOR WINTER <br />CONCRETING AND ACIS05(305) FOR HOT WEATHER CONCRETING. USE <br />INTERIOR MECHANICAL VIBRATORS WITH TWO RPM MINIMUM FREQUENCY. DO <br />NOT OVER -VIBRATE. CONCRETE SHALL BE PLACED MONOLITHICALLY BETWEEN <br />CONSTRUCTION OR CONTROL JOINTS. PROTECT ALL CONCRETE FROM <br />PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN <br />DAYS AFTER PLACING. <br />31 STRENGTH <br />TWENTY-EIGHT DAY COMPRESSIVE STRENGTHS SHALL BE AS FOLLOWS: <br />FOOTINGS 40DO PSI <br />CONCRETE SUPPLIER TO PROVIDE TEST RECORDS PER SECTION 5.3 OF ACI 318. <br />3.3 MATERIALS <br />3.3.1 CEMENT: ASTM C150, TYPE I OR TYPE II. ENGINEER'S APPROVAL IS <br />NEEDED FOR USE OF TYPE III CEMENT. <br />3.32 COARSE AND FINE AGGREGATE: ASTM C33. <br />3.3.3 WATER SHALL BE CLEAN AND POTABLE. <br />3.3.4 FLYASH: ASTM 0618 CLASS C (CLASS F SHALL BE ALLOWED IF <br />PERMITTED BY THE STRUCTURAL ENGINEER) <br />3.3.5 GROUND GRANULATED BLAST FURNACE SLAG (GGBFS): ASTM C9119 <br />GRADE 100 OR 120. GGBFS SHALL NOT BE PERMITTED UNLESS <br />REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER MIX <br />DESIGNS SUBMITTED INCLUDING GGBFS SHALL INCLUDE SHRINKAGE <br />TEST RESULTS AT 28 DAYS. <br />3.4 ADMIXTURES <br />3.4.1 WATER REDUCING ADMIXTURE: ASTM C494. ADMIXTURES SHALL BE <br />USED IN EXACT ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />3A2 WATER REDUCING ADMIXTURES SHALL BE USED AT ALL HEAVILY <br />CONGESTED AREAS (I.E. CONCRETE BEAMS, COLUMNS AND WALLS <br />WITH REINFORCING SPACING OF 4.OR LESS) <br />3.4.3 CONCRETE USING ADMIXTURES TO PRODUCE FLOWABLE CONCRETE <br />MAY BE USED SUBJECT TO ENGINEER'S APPROVAL. <br />3A.4 AIR ENTRANMENI: ASTM C260 AND ASTM C494 ENTRAIN 5% <br />PLUSNINUS 1.5% BY VOLUME IN ALL CONCRETE EXPOSED TO <br />WEATHER. <br />3.4.5 NO OTHER ADMIXTURES PERMITTED UNLESS APPROVED BY THE <br />ENGINEER. <br />3.10 FORMWORK AND SHORING <br />3.10.1 FOLLOW RECOMMENDED PRACTICE FOR CONCRETE FORMWORK <br />(ACI-347). <br />3.11 REINFORCING STEEL: <br />3.11.1 DETAIL, FABRICATE, AND PLACE PER ACI-315 AND ACI-318. SUPPORT <br />REINFORCEMENT WITH APPROVED CHARS, SPACERS, OR TIES. <br />3.11.2 DEFORMED BAR REINFORCEMENT: ASTM A615 GR 60 <br />3.11.8 EXCEPT AS NOTED SPECIFICALLY ON THE DRAWINGS, ALL CONCRETE <br />REINFORCEMENT SHALL BE LAP -SPLICED AS FOLLOWS: <br />M6 AND SMALLER 48 X BAR DIAMETER <br />#7 AND LARGER 56 X BAR DIAMETER <br />NO MORE THAN 50% HORIZONTAL OR VERTICAL BARS SHALL BE <br />SPLICED AT ONE LOCATION <br />3.11.10 EXCEPT AS NOTED SPECIFICALLY ON THE DRAWINGS, PROVIDE <br />CORNER BARS TO MATCH QUANTITY AND DIAMETER OF HORIZONTAL <br />REINFORCEMENT AND LAP WITH HORIZONTAL REINFORCEMENT AS <br />FOLLOWS: <br />86 AND SMALLER 4B X BAR DIAMETER <br />ff7ANDLARGER 56XBARDIAMETER <br />THESE CORNER BARS SHALL BE PLACED AT ALL CORNERS AND <br />INTERSECTIONS IN CONCRETE FOOTINGS AND WALLS. <br />3.12 CONCRETE COVER ON REINFORCING SHALL BE AS FOLLOWS (UNLESS SHOWN <br />OTHERWISE): <br />BOTTOM OF FOOTINGS 3' <br />FORMED EARTH FACE AND SLAB ON GRADE T <br />3.14 CONDUIT AND PIPING EMBEDDED IN CONCRETE <br />3.14.1 ELECTRICAL CONDUIT SHALL NOT BE PLACED WITHIN A SLAB ON <br />GRADE, BUT PLACED BELOW THE SLAB IN THE SUBBASE. <br />3.15 GROUT FOR BEARING PLATES <br />THE NON -SHRINK GROUT SHALL MEET ASTM C1107 GRADE B OR EQUIVALENT <br />(MASTERFLOW 928 BY BASF OR APPROVED EQUIVALENT). GROUT SHALL BE A <br />PRE -PACKAGED HYDRAULIC CEMENT BASED MINERAL AGGREGATE GROUT, <br />MIXED, PLACED AND CURED AS RECOMMENDED BY THE MANUFACTURER <br />COMPRESSIVE STRENGTH SHALL EXCEED 60DO PSI AT 28 DAYS. <br />5. METALS <br />52 STRUCTURAL STEEL GENERAL REOUIREMENTS <br />52.1 MISCELLANEOUS PLATES SHALL BE ASTM A36 FrW KSI. <br />52.5 STEEL ANCHORAGE ELEMENTS <br />A EXPANSION ANCHORS IN CONCRETE SHALL BE STAINLESS STEEL <br />WHEN INSTALLED IN EXTERIOR ENVIRONMENTS, AND CARBON <br />STEEL AT ALL OTHER LOCATIONS, UNLESS NOTED OTHERWISE. <br />EXPANSION ANCHORS SHALL BE EITHER HILT] KWIK BOLT TZ (ICC <br />ESR-1917), SIMPSON STRONG-B%T2 (ICC ESR-3mT), POWERS <br />POWERSTUD+ SD2 (ICC ESR-2502), OR APPROVED EQUIVALENT <br />WITH A CURRENT CODE REPORT THAT COMPLIES WITH THE <br />CURRENT EDITION OF THE IBC RATED FOR USE IN CRACKED <br />CONCRETE AND RATED TO RESIST WIND AND SEISMIC FORCES IN <br />THE SEISMIC DESIGN CATEGORY NOTED IN SECTION 1.6. <br />S. ADHESIVE ANCHORS IN CONCRETE SHALL BE THREADED ANCHOR <br />RODS OR REPAR DOWELS USING AN INJECTABLE ADHESIVE <br />EITHER HILTI HIT-HY 200 (]CC ESRS187), SIMPSON AT-XP (IAPMO <br />ER-263), OR APPROVED EQUIVALENT WITH A CURRENT CODE <br />REPORT THAT COMPLIES WITH THE CURRENT EDITION OF THE IBC <br />RATED FOR USE IN CRACKED CONCRETE AND RATED TO RESIST <br />WIND AND SEISMIC FORCES IN THE SEISMIC DESIGN CATEGORY <br />NOTED IN SECTION 1.5. <br />5.2.7 METAL PROTECTION: ALL STEEL EXPOSED TO WEATHER, MOISTURE, <br />SOIL, OR AS NOTED SHALL BE GALVANIZED PER ASTM A-123 ORA753 <br />AS APPLICABLE. ALL OTHER STEEL SURFACES SHALL BE SHOP <br />PRIMED AFTER FABRICATION. <br />REPAIR ALL DAMAGED AREAS OF GALVANIZED PARTS SUCH AS FIELD <br />WELDS, ETC. APPLY REPAIR COATING THICKNESS GREATER THAN OR <br />EQUAL TO ORIGINAL ZINC COATING THICKNESS. <br />comwaly rfan,w. <br />rries�uvgva <br />NapMpi <br />131DOM <br />TACOMA SEATTLE <br />2215 North 301h Shea. SuLe 300, Tacoma, WA 98403 <br />253.3831422 m <br />12DO SbO Avenue, Sub 1620, Sea6e, WA 98101 <br />M62b72425 m <br />Protect Title <br />CASCADE COFFEE <br />NEW EXTERIOR <br />EQUIPMENT <br />c1e, <br />CASCADE COFFEE, INC. <br />152575th ST SW SUITE 100 <br />EVERETT, WA 9820.3 <br />Job No. <br />2150149.20 <br />ISSve Set 8 Date <br />PERMIT SET <br />VAY 6, 2015 <br />0o�in <br />� � A <br />�oA�noe�t OK'�� <br />BSSIONAL <br />� ar oocuanrz <br />Revisions: <br />Sheet Title: <br />GENERAL STRUCTURAL <br />NOTES <br />Desicned by, Drawn by, Checked by, <br />AS DR SS <br />Sheet No. <br />S0.1 <br />of Sheets <br />