Laserfiche WebLink
GENERAL <br />YES <br />NO <br />Bathroom doors are easily and quickly openable from the outside when locked <br />1Y <br />13 <br />Carbon Monoxide alarms are installed as required in R315 on each level of the home. <br />Or <br />13 <br />Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room, outside each separate <br />sleeping area in the immediate vicinity of sleeping rooms (11314). <br />0 <br />Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all <br />parts of the dwelling upon activation of a single device. <br />1W oe <br />0 <br />Access road and water supply meet local fire jurisdictional requirements. <br />0 <br />R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable <br />with one hand and shall not require tight grasping, pinching or twisting of the wrist (lever -type). <br />Pocket doors shall have graspable hardware available when in the closed or open position. <br />13 <br />R311.8 Ramp <br />YES <br />NO <br />Inside Ramp <br />I N/A <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in <br />R330.9) <br />0 <br />R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where <br />ramp changes directions. <br />El <br />1 <br />R330.9.1 Handrails require n both sides of ramp. <br />13 <br />Outside Ramp I N/A Mrl Jug lAl <br />YoK <br />LNO <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizonta (8.3%slope). (Exception R311.8.1 Not allowed in <br />R330.9) <br />?� <br />0 <br />-R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where <br />ramp changes directions. <br />'* <br />� 13 <br />R330.9.1 Handrails required on both sides of ramp. <br />Q <br />0 <br />R312.1.1 Guards shall be located along open -sided walking surfaces, that are located more than 30 inches measurgO <br />vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br />Guards below are depicted vertically as an example only. <br />13 <br />13 <br />Guard <br />36" min <br />Handrail both sides <br />--� Less than 4" F 34" - 38" <br />Tx3'min. <br />landing <br />Tx3'min <br />3' One unit vertical in twelve units horizontal 3' — <br />minimum is an 8.3% slope all along surface of the ramp. minimum <br />Implementation Date: 2021 February 01 <br />Updated: 2021 Februa <br />S <br />