GENERAL <br />YES <br />NO <br />Bathroom doors are easily and quickly openablefrom the outside when I ocked <br />❑ <br />❑ <br />Carbon Monoxide alarms are installed as required in R315 on each level of the home. <br />❑ <br />❑ <br />Smoke alarms are installed on all levels of the dwel I ing, in each resident sleeping room, outside each separate <br />sleepingarea inthe immediate vicinity ofsleeping rooms (R314). <br />❑ <br />❑ <br />SmokeandCarbon Monoxidealarmsare installed insuchamanner sothattheaudiblewarningmaybe heard inall <br />parts of the dwelling upon activation of a single device. <br />❑ <br />❑ <br />Access road and water supply meet localfirejurisdictionalrequirements. <br />❑ <br />❑ <br />R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand <br />and shall not require tight grasping, pinching ortwistingofthe wrist (lever -type). <br />❑ <br />1 ❑ <br />Pocket doors shall have graspable hardware availablewhen in the closed or open position. <br />R311.8 Ramps <br />YES <br />NO <br />Inside Ramp N/A <br />❑ <br />❑ <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH) <br />R311.8.2 Landing Requirements: min. 3X3 foot landing attop/bottom, where doors open onto ramps, and where rampchanges <br />directions. <br />❑ <br />❑ <br />R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. <br />❑ <br />❑ <br />Outside Ramp N/A <br />YES <br />I NO <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH ) <br />R311.8.2 Landing Requirements: min. 3X3 foot landingattop/bottom, where doors open onto ramps, and where rampchanges <br />directions. <br />❑ <br />❑ <br />R325.9.1 Handrails required on both sides of ramp in accordancewith R311.8.3.1—R311.8.3.3. <br />❑ <br />❑ <br />Guards below are depicted vertically as an example only. All Ramps must have Guards <br />❑ <br />❑ <br />Gi <br />36 <br />minimum is an 8.3% slope all along surface of the ramp. minimum <br />R3112 Means'of Egress <br />YES <br />NO <br />R311.2 Door must be side -hinged with min. width of32 inches between face of door and stop. Height not less than 78 inches. <br />❑ <br />❑ <br />R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand <br />and shall not require tight grasping, pinchingor twisting ofthe wrist (lever -type). <br />❑ <br />❑ <br />R325.4 Required exit door hardware shall unlock insideand outside mechanismswhen exitingthe building a I lowing re -entry <br />without use of key, tool or special knowledge. <br />❑ <br />❑ <br />R311.7Stairways N/A <br />YES <br />NO <br />R311.7.5.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures built prior to July 1, 2004) <br />❑ <br />❑ <br />R311.7.5.2Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures buiItprior toJuly1, 2004) <br />R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numberingfrom one riser to m ultiple <br />risers. Handrails shall be installed in accordance with R311.7.8.1—R311.7.8.4 <br />❑ <br />❑ <br />Effective: 2013 July 01 <br />Updated: 2017 February <br />