My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 100TH ST SW ELDANA AFH LLC 2021-12-13
>
Address Records
>
100TH ST SW
>
1502
>
ELDANA AFH LLC
>
1502 100TH ST SW ELDANA AFH LLC 2021-12-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2021 8:51:08 AM
Creation date
9/16/2021 9:28:16 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1502
Tenant Name
ELDANA AFH LLC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NAME OF AFH: <br />SECTION MUSTBE COMPLETED BYTHEBUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br />PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN —USING THEIR PROSPECTIVE RESIDENT <br />BEDROOM DESIGNATIONS OF A 8 CD E AND F AND CLASSIFICATION CODE S, NS1 OR NS2. <br />SECTION 5 — BUILDING INSPECTOR'S INSPECTION CHECKLIST <br />R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br />Type S —where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. <br />Type NS1— where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. <br />Tvpe NS2— where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R325.9 are provided to evacuate residents to public area. <br />SLEEPING ROOM A ` E3 Type S <br />E3 Type NS1 113 <br />Type NS2 <br />YES <br />NO <br />Closetdoor/sare readily openablefromthe inside JE3Yes <br />JE3No I Smokealarmis installed inthe bedroom <br />[3 <br />13 <br />Bedroom door opens easily and quicklyfromthe outside when locked <br />0 <br />0 <br />Sleeping roomwinclow has a netopening of 5.7SF (minimum dimensions at least 24"high; atleast20"wide) <br />EXCEPT per R310.2.1: at -grade escape wi ndows —may have net clearance opening 5 SF <br />0 <br />13 <br />Sleeping room window has a maximum sill height of44"abovefloortoclear opening; nosteps under windowallowe <br />E3 <br />0 <br />SLEEKING ROOM B Type S <br />Type NS1 <br />Type NS2 <br />YES <br />NO <br />Closetdoor/sare readily openablefromtheinside [3Yes JE3No I Smokealarm is installed in the bedroom <br />[3 <br />0 <br />Bedroom door opens easily and quicklyfromthe outside when locked <br />0 <br />0 <br />Sl eepi ng room window has a net opening of 5.7 SF (minimum dimensions at I east 24"high; at I east 20"wide) <br />EXCEPT per R310.2.1: at -grade escape wi nlilows— may have net clearance opening 5 SF <br />0 <br />13 <br />Sl eepi ng room window has a maximum sill height of 44"abovefloor to clear opening; no steps under window a Ilowec13 <br />0 <br />SLEEPING ROOM,C ' Type S <br />Type NS1 <br />Type NS2 <br />YES <br />NO <br />Closet door/s are readily openablefromthe inside 113Yes <br />j[3No I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quicklyfrom the outside when locked <br />13 <br />13 <br />S1 eepi ng room window has a net opening of 5.7 SF (minimum dimensions at I east 24"high; at I east 20"wide) <br />EXCEPT per R310.2.1: at -grade escape windows —may have net clearance opening 5 SF <br />13 <br />13 <br />Sleeping roomwindowhasa maximum sill height of44"abovefloor toclear opening; nosteps under window allowe <br />SLEEPING ROOM D ' Type S <br />113 Type NS1JE3 <br />Type NS2 <br />YES <br />NO <br />.Closetdoor/sare readily openablefromtheinside <br />JOYes JE3No I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quicklyfrom the outside when locked <br />0 <br />0 <br />Sleeping room window has a net opening of5.7SF(minimum dimensions atleast 24"high;atI east 20"wide) <br />EXCEPT per R310.2.1: at -grade escapewi ndows —may have net clearance opening 5 SF <br />[3 <br />13 <br />SI eepi ng room window has a maximums ill height of 44" a bove fl oor to clear opening; no steps under window a Ilowe <br />SLEEPING ROOM E Type S <br />Type NS1 <br />Type NS2 <br />YES <br />NO <br />Closetdoor/sare readily openablefromthe inside DYes JDNo I Smoke alarm is installed inthe bedroom <br />13 <br />13 <br />Bedroom door opens easily and quicklyfrom the outside when locked <br />13 <br />Q <br />Sleeping room window has a net opening of5.7SF(minimum dimensions atleast 24"high;atI east 20"wide) <br />EXCEPT per R310.2.1: at -grade escape wi ndows —may have net clearance opening 5 SF <br />13 <br />0 <br />Sleeping room wi ndow has a maximum sill height of 44" a bove fl oor to clear opening; no steps under window a Ilowe <br />SLEEPING ROOM F, '' : Type S <br />Type NS1 <br />Type NS2 <br />YES <br />NO <br />Closetdoor/sare readily openablefromthe inside <br />JE3Yes JE3No I Smoke alarm isinstalled in the bedroom <br />Bedroom door opens easily and quicklyfrom the outside when locked <br />[3 <br />13 <br />SI eepi ng room window has a net opening of 5.7 SF (minimum dimensions at I east 24"high; at I east20"wide) <br />EXCEPT per R310.2.1: at -grade escape windows —may have net clearance opening 5 SF <br />0 <br />0 <br />SI eepi ng room window has a maximums ill height of 44" a bove fl oor to clear opening; no steps under window a Ilowe <br />Effective: 2013 July 01 <br />Updated: 2017 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.