Laserfiche WebLink
6/14/2021 https://waenergycodes.com/print_project summary_form.php?k=Y29tYm9fdGZ2X3B0PW11Y19odmFjX3N5c196b25 bbrFl . u I DcGRfYWx0ZXJhdGlvbiZOZnY9bWVjX2h2YWNfc31z... <br /> MECHANICAL COMPLIANCE SUMMARY - <br /> 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all RI ,, d,,, \ to {, Administered by:©2021 NEEA,All rights reserved <br /> Project Title Harvey TI-2018 WSEC For ding Dep \.User <br /> 6202 Associated Blvd � <br /> Project Address I Date: Jun 14,2021 <br /> � <br /> Project&Applicant Everett,WA 98201 �etJCi\ <br /> Information Applicant Name Alex Burkhart • <br /> Applicant Phone 206-763-1744 CN ( . veCC <br /> Applicant Email alexb@evergreenhvac.com <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> General Occupancy All Commercial General Building Use Type Office,Professional Services Building Cond.Floor Area 1,546 <br /> New Building Project Cond.Floor Area 1,546 <br /> General Project Types Alteration or Addition Alteration Single Zone Systems&Equipment Floors Above Grade 1 <br /> a Mechanical Scope <br /> Mechanical Scope Compliance Method Compliance Method 1-General <br /> Mechanical Project Description Installation of one(1)split system heat pump,one(1)energy recovery ventilator,one(1)electric duct heater,two(2)electric wall heaters,one(1)exhaust fan,ductwork,and grilles/diffusers. <br /> Economizer Equipment Efficiency <br /> Project DOAS Ventilation Higher Equipment <br /> Mechanical Scope Exception(s) OptionApplied? <br /> Compliance <br /> Mechanical Compliance Pe Applied? Provided? Efficiency <br /> Verification <br /> Scope and Method • <br /> Alteration Single Zone Systems& Yes Yes NA COMPLIES <br /> Equipment <br /> Additional Efficiency Higher equipment efficiency and fan FEG <br /> Credits Included(AEC) <br /> Does building include occupancy classifications requiring Yes Does project include DOAS equipment? Yes <br /> DOAS? <br /> Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No <br /> TSPR? <br /> Scope&Space Conditioning ALTERATION-SINGLE ZONE SYSTEMS&EQUIPMENT Compliance Verification COMPLIES <br /> Single Zone Air Systems Category-Heat pump,unitary,thru-wall,SDHV <br /> Air Systems Summary Information <br /> Quantity Supply Airflow Ventilation CFM Ventilation Energy Recovery <br /> System/Equip ID of Items Control Ventilation Standard (Total if Multiple Items) Air Source Paired with DOAS Ventilation energy recovery Efficiency(%) <br /> IU-1/OU-1 Constant volume IMC Ventilation 300 Separate DOAS ERV-1 Yes per C403.5 Energy Recovery 60 <br /> Air Systems&Equipment-Cooling <br /> System/ Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance <br /> Equip ID Cooling System/Equip Type Specific Type per item Btu/h Multiplier Multiplier(FL&PL) Multiplier(AEC&Econo) EfficiencyUnits Load EfficiencyUnits Verification <br /> 9 P (Btu/h) P P P <br /> IU-1/OU-1 Heat pump,air cooled Split system 17,400 1 1.0 1 17.4 SEER IEER COMPLIES <br /> Air Systems&Equipment-Heating <br /> System Heating System/Equip Type Specific Type Heat Pump Heating Capacity(Btu/h) Cooling Capacity(Btu/h) AEC Efficiency Proposed Heat Pump HPH Proposed Low OSA LTH Efficiency Compliance <br /> /Equip ID _ Multiplier Heating Efficiency Units Temp Efficiency Units Verification <br /> IU-1/OU-1 Heat pump,air cooled,heating Split system 49,500 17,400 1 10.3 HSPF COP COMPLIES <br /> Air Systems&Equipment Details <br /> System/Equip ID Area(s)Served Location In Project Documents-Plan/Detail# <br /> IU-1/OU-1 Office ALL <br /> Heating Section/Auxiliary Heating Type:Other source Economizer Compliance Method:Applying air-side economizer exception <br /> Air-side economizer exception applied:Exp I-DOAS paired with cooling system(Note equip location limitations) WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(2)-Unitary and Applied I feat Pumps <br /> Proposed Low OSA Temp Efficiency: LTH Units:COP <br /> https://waenergycodes.com/print_project summary_form.php?k=Y29tYm9fdGZ2X3BOPW11Y19odmFjX3N5c196b25pbmdfc2luZ2xIJTdDcGRfYWx0ZXJhdGlvbiZOZnY9bWVjX2h2YWNfc31zX3pvbm1uZ1... 1/2 <br />