My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6202 ASSOCIATED BLVD 2021-10-12
>
Address Records
>
ASSOCIATED BLVD
>
6202
>
6202 ASSOCIATED BLVD 2021-10-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2021 1:35:30 PM
Creation date
9/22/2021 8:52:23 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6202
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements List, pg 3 of 25 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> YES C403.3.5 Dedicated outdoor air For buildings with occupancies required to M001 <br /> C403.3.5.4 systems comply with the DOAS provisions per Table <br /> C403.3.5,identify on plans all occupancies in <br /> the building and indicate which occupied <br /> spaces are required to have ventilation air <br /> delivered by a DOAS;or exception applied <br /> NA If natural ventilation exception is applied, <br /> identify these spaces on plans;indicate <br /> operable window area complies with IMC <br /> Section 402;provide documentation <br /> describing how required ventilation will be <br /> provided during all occupied hours,including <br /> during inclement weather <br /> NA If high efficiency VAV exception is applied, <br /> identify these spaces on plans;refer to Single <br /> Zone VAV section for Groups A-1,A-2 and <br /> A-3 occupancy classifications,or Multiple <br /> Zone VAV for other than Groups A-1,A-2 <br /> and A-3(per Table C403.3.5) <br /> NA If compliance with the DOAS provisions is <br /> deemed to be impractical,provide <br /> documentation that demonstrates the alternate <br /> design strategy applied that achieves a <br /> comparable level of energy efficiency,as pre- <br /> approved <br /> by the AHJ <br /> NA Refer to Requirements List section after <br /> Multiple-Zone Air Systems for High <br /> Efficiency Multiple-Zone VAV Systems <br /> exception to C403.3.5 DOAS <br /> NA Refer to Requirements List section after High <br /> Efficiency Multiple-Zone Air Systems for <br /> High Efficiency Single-Zone VAV Systems <br /> exception to C403.3.5 DOAS <br /> YES C403.3.5.1 DOAS energy For all DOAS systems,indicate exhaust air M001 <br /> recovery method and ER method and basis of rated effectiveness <br /> effectiveness (sensible or latent);indicate>_60%sensible or <br /> z 50%enthalpy ER effectiveness based on <br /> delta between outdoor air and return air <br /> enthalpies at design conditions;or exception <br /> applied <br /> NA If applying exception for DCV,identify <br /> occupant load in space and airflow control <br /> configured to reduce ventilation rate by Z <br /> 50%when occupancy is less than design <br /> occupancy <br /> YES C403.3.5.1 DOAS fan power For DOAS with total system fan hp<5 hp, M001 <br /> indicate total system fan power does not <br /> exceed 1 watt per cfm <br /> NA For DOAS with total system fan hp z 5 hp, <br /> indicate total system fan power complies with <br /> fan power limitation per Section C403.8.1 <br /> Page 3/25 <br />
The URL can be used to link to this page
Your browser does not support the video tag.