My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6202 ASSOCIATED BLVD 2021-10-12
>
Address Records
>
ASSOCIATED BLVD
>
6202
>
6202 ASSOCIATED BLVD 2021-10-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2021 1:35:30 PM
Creation date
9/22/2021 8:52:23 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6202
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements List, pg 6 of 25 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA For other mechanical cooling systems <br /> (includes DX and chilled water coils)that <br /> control space temperature by modulating <br /> airflow(in lieu of,or in addition to, <br /> controlling capacity in response to space <br /> temperature)-Provide fan controls for <br /> modulating supply airflow;indicate minimum <br /> fan speed is 5_50%of full speed drawing<_ <br /> 30%of full speed fan power during periods of <br /> low cooling or ventilation only;or exception <br /> applied <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION,MORE EFFICIENT HVAC EQUIPMENT&FAN PERFORMANCE-MUST COMPLY <br /> WITH ALL 3 PROVISIONS TO BE ELIGIBLE <br /> YES C406.2.1 HVAC system To comply with this additional efficiency M001 <br /> selection credit,provide calculations that demonstrate <br /> (based on heating and cooling output capacity) <br /> that 90%or more of all HVAC equipment <br /> serving conditioned floor areas have a <br /> corresponding WSEC listed efficiency;or <br /> exception applied <br /> YES C406.2.2 Minimum equipment In addition to system selection requirement, M001 <br /> efficiency indicate that all associated heating and cooling <br /> equipment have a rated efficiency for all <br /> equipment performance criteria(heating; _ <br /> cooling,full load,part load)that is at least <br /> 15%better than the listed WSEC efficiency; <br /> include specific equipment exceptions applied <br /> NA For systems required to provide a TSPR <br /> I report per C403.1.1,demonstrate that the <br /> proposed design ratio is at minimum 10% <br /> higher than the standard reference design ratio <br /> NA For projects complying via weighted average <br /> efficiency exception,include calculations that <br /> demonstrate the overall average better than <br /> code efficiency of all equipment performance <br /> criteria for all equipment is>_15%;indicate <br /> that all equipment has at least 5%better than <br /> code efficiency <br /> NA For systems serving low energy and semi <br /> heated spaces,indicate that 90%or more of <br /> installed heating output capacity is provided <br /> by electric infrared or gas-fired radiant <br /> equipment for localized heating applications <br /> only <br /> NA C406.2.3 Minimum fan In addition to system selection and efficiency <br /> efficiency grade requirements,indicate rated FEG of all z 1 hp <br /> (750 watt)stand alone supply,return and <br /> exhaust fans is z 71;indicate these fans are <br /> sized so the fan efficiency at design <br /> conditions is within 10%of the maximum <br /> total or static efficiency <br /> VENTILATION,EXHAUST&ENERGY RECOVERY <br /> C403.2.2.1 Ventilation Indicate method of ventilation air delivery <br /> (natural or mechanical)for each zone <br /> ra—D' 6/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.