My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6202 ASSOCIATED BLVD 2021-10-12
>
Address Records
>
ASSOCIATED BLVD
>
6202
>
6202 ASSOCIATED BLVD 2021-10-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2021 1:35:30 PM
Creation date
9/22/2021 8:52:23 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6202
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements List, pg 9 of 25 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> For kitchens with total hood exhaust <br /> exceeding 2,000 cfm,indicate energy <br /> efficiency compliance method(demand ventilation,energy recovery,or transfer air <br /> that would otherwise be exhausted);or <br /> exception applied <br /> C403.7.7.2 Laboratory exhaust For buildings with total lab exhaust>5,000 <br /> systems energy cfm,indicate method of energy recovery used <br /> recovery to pre-condition laboratory make-up air; <br /> energy recovery effectiveness(min 25°F <br /> increase in outside air temperature);or <br /> alternative method per exception(VAV <br /> exhaust,semi-conditioned makeup,or CERM <br /> calculation) <br /> C403.7.7.3 Transfer air For spaces where conditioned supply air is <br /> utilized as transfer air to balance mechanical <br /> exhaust,indicate basis of transfer airflow <br /> (supply required to meet loads,health/safety <br /> requirement,air that would normally be <br /> exhausted);or exception applied <br /> C403.7.8.1 Shutoff dampers for Indicate locations of outdoor air intake, <br /> C403.7.8.3 building isolation exhaust and relief outlet dampers on plans; <br /> indicate whether dampers are Class 1 <br /> motorized or-gravity and exception applied <br /> (include leakage rating,cfm/sf) <br /> C403.5.3.4 Relief of excess Indicate relief air outlets are sized and <br /> outdoor air configured to relieve excess building air <br /> during air economizer operation to prevent <br /> building over-pressurization <br /> Indicate relief air outlet are located to avoid <br /> recirculation into the building <br /> C403.7.8.2 Shutoff dampers for Indicate locations of return air dampers that <br /> C403.7.8.3 return air are integral to airside economizer operation; <br /> verify dampers are motorized;indicate <br /> whether dampers are Class 1,or within <br /> packaged equipment eligible for leakage <br /> rating exception(include leakage rating, <br /> cfmisf) <br /> C403.7.8.4 Damper actuation Indicate automatic controls configured to <br /> close outdoor air intake,exhaust and relief <br /> outlet dampers during unoccupied equipment <br /> operation;not including economizer cooling, <br /> night flush or IMC required outdoor air/ <br /> exhaust <br /> C403.7.8.1 Shutoff dampers for Indicate location of stairway and elevator <br /> C403.7.8.3 stairway and elevator '; hoistway shaft vent dampers on plans;verify <br /> hoistway shaft vents dampers are Class 1 motorized;or exception <br /> applied <br /> Indicate method of activation of stairway and <br /> elevator hoistway shaft vent dampers(fire <br /> alarm or interruption of power) <br /> Page 9/25 <br />
The URL can be used to link to this page
Your browser does not support the video tag.