811 SE EVERETT MALL WAY OLYMPIC HOT TUB 2025-09-26
>
Address Records
>
SE EVERETT MALL WAY
>
811
>
OLYMPIC HOT TUB
>
811 SE EVERETT MALL WAY OLYMPIC HOT TUB 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 1:09:20 PM
Creation date
9/22/2021 11:39:57 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
811
Tenant Name
OLYMPIC HOT TUB
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting - Building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R Revised Nov 2017 <br /> Project Title: Olympic Hot Tub Retail Tenant Improvement Date 2/18/2021 <br /> Calculation 0 New Construction 0 Addition- O Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where>-50%of O Spaces where the Use <br /> luminaires are replaced luminaires are replaced is changing(C505) <br /> LPA 0 Standard 0 Additional Efficiency Package Option O <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. I User Note <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattages'°TE <br /> Watts Allowed <br /> Location(plan#, Gross Interior Allowed 2 <br /> (watts/ft2 area) <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 NOTE 2 <br /> Office Al-1, 100-105 Restroom,storage,break area,and open office 634 0.66 419 <br /> Retail Al-1, 106-108 Water Care,Mood Room&Showroom 2997 1.01 3027 <br /> Total 3631 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 3,4,5,6 Fixtures Fixture NOTE 7 Watts Proposed <br /> Office A2-1, 100 ceiling mounted LED square light fixture 2 14 28 <br /> Office _ A2-1, 100 LED Vanity Wall Sconce 1 21 21 <br /> Office A2-1,102-105 2X2 recesssed LED light fixture 10 35 350 <br /> Retail A2-1, 106 2X2 recesssed LED light fixture 2 35 70 <br /> Retail A2-1, 107 LED track lighting 33 37 1221 <br /> Retail _ A2-1, 108 Recessed can lights 4 12 48 <br /> Retail A2-1, 108 LED Tape 88 3 264 <br /> Compliance by Building Area NOTE 8 <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Set LPA <br /> Office 419 399 Calculation <br /> Type <br /> Confirm all fixtures are reported under proposed lighting-low watts Set LPA <br /> Retail 3027 1603 Calculation <br /> relative to maximum allowed. <br /> Type <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 3446 2002 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Unlit Message-Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting <br /> Power Allowance. <br /> Note 3-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included). <br /> For track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low <br /> voltage <br /> lighting,enter the wattage of the transformer. For line voltage track/busway systems,enter the larger of the attached luminaire wattage or <br /> 50 watts/lineal foot,or enter the wattage limit of permanent current limiting device. 3 � <br /> Note 8-Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage <br /> ti..ti...,...,o..:w:.... n...,,s........:....s,.n........�........�sa.,o..a.r......n.....,e�..ati...�.........r.......,..,,.ati <br />