r <br /> Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> " Project Title: Wendy's Interior Dining Room/Toilet Room Tenant Improvement Date 8/6/2018 <br /> Calculation O-is'k r2 0 For Building Department Use <br /> Addition- Addition <br /> Area NOTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where 50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> LPA QQ Standard 0 Additional Efficiency Package Option 0 <br /> CalculationC406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Height'" Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Toilet 102,103 Restroom:all other 8'-0" 151 0.780 118 <br /> Service Counter Food preparation 7'-10" 387 0.790 306 <br /> 104 <br /> Dining Rm 100 Dining area:Bar/lounge/leisure dining 7'-10" 2079 0.860 1788 <br /> Total Area 2 617 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE a Allowed Watts 2212 <br /> Proposed Lighting Wattage"°TE s <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed <br /> Toilet 102,103 LSI 2x4 LED 2 lamp troffer 2 40 80 <br /> Service Counter LSI 2x4 LED 2 lamp troffer 3 4 0 12 0 <br /> 104 <br /> Dining 100 2x4 -LED TROFFER-5000 Lumens-38watt-4000k-center 16 38 608 <br /> basket Diva Light TR46-46L-40K-dlo <br /> Didning 100 UM-4 1 60 60 <br /> Dining 100 Al can light LED 8 10 80 <br /> Dining 100 UM2-Track Light 3 60 180 <br /> Dining 100 Solarium Track Lighting 5 60 300 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 142 8 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they maybe combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br /> \ \71 <br />