My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7514 EVERGREEN WAY 2021-09-22
>
Address Records
>
EVERGREEN WAY
>
7514
>
7514 EVERGREEN WAY 2021-09-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 4:18:52 PM
Creation date
9/22/2021 4:18:23 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7514
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Wendy's Kitchen addition&Alteration-7514 Evergreen Wy Date 8/6/2018 <br /> Calculation 0 0 Addition- O Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> 0 Spaces where<50%of 0 Spaces where z 50%of o <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard 0 Additional Efficiency Package Option a <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE" <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Wattsper ft2 <br /> 9 (watts/ft2 x area) <br /> Office/Employ.Rm Office:Enclosed 8'-0" 144 0.890 128 <br /> Kitchen Food preparation 7'-10" 1075 0.790 849 <br /> Walk in Cooler room Storage <br /> Freezer g 7'-6" 250 0.500 125 <br /> Total Areal 1469 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> .71 <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 1103 <br /> Proposed Lighting Wattage"w" <br /> Location(plan#, Number of Watts/ ` f Watts <br /> NOTE 4,5,6 NOTE 7 ' 3 rat <br /> room#) Fixture Description Proposed <br /> Fixture fi� �• Pro osed <br /> Office/Employ RM 2X4 2X4 LED TROFFER;LSI OR EQUAL 2 40 , ", ' 80 <br /> Kitchen LSI 2x4 LED 2 lamp troffer 15 40 `_ s tf 600 <br /> walk in � � <br /> cooler/freezer 40w incandescent lamp 6 38 y 228 <br /> mop sink 23w recessed can light fluorescent lamp 1 23 23 <br /> 4 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts' 931 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed fighting fixtures including exempt fighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g.T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For fine voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.if a <br /> building addition will comply as combined with the overall existing building fighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br /> 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.