My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
405 RIVERSIDE RD PODS 2021-09-28
>
Address Records
>
RIVERSIDE RD
>
405
>
PODS
>
405 RIVERSIDE RD PODS 2021-09-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/28/2021 1:51:53 PM
Creation date
9/24/2021 1:54:59 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
405
Tenant Name
PODS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; I ! • , - • 4 - - - . 1 . - - 40 • <br /> 2018 WSEC Requirements for Commercial B ,.s including Group R2,R3&R4 over 3 stories&all R1 - dministered by @2021 NEEA,All rights reserved <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br /> Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C402.5.4 Doors and access Indicate method of sealing of these openings • <br /> openings to shafts, (gasketing,weatherstripping,other sealing • <br /> chutes,stairways and method);or exception taken4 • <br /> elevator lobbies <br /> C402.5.5 Outdoor air intakes, Indicate locations of all stairway-enclosure. <br /> C403.7.8 exhausts and relief elevator shaft and buildin pressurization <br /> gp <br /> openings relief openings.Outside airootkec and { <br /> exhaust openings$ <br /> C402.5.5 Outdoor air intakes, Note in envelope plans that all relief,outside <br /> C403.7.8 exhausts and relief air intake and exhaust openings shall be <br /> openings provided with dampers in accordance with <br /> Mechanical Section C403.7.84 <br /> C-R)2.5.8 Recessed lighting in Indicate method of sealing between fight <br /> building envelope fixture housing and wall or'ceflin«4 <br /> C402.5.8 Recessed lighting in Note in envelope plans that all recessed <br /> building envelope lighting fixtures shall be IC rated and have an <br /> air leakage rating not greater than 2 cfm per <br /> ASTM E283 test;include these requirements • <br /> in lighting fixture schedules4 <br /> C402.5,6 Loading dock seals Indicate weather seal at cargo and loading <br /> dock doors4 <br /> C402.5.7 Vestibules Indicate locations and dimensions of <br /> vestibules for building entrances.also indicate <br /> vestibule information for exit-ttn£y doors in <br /> buildings where separate doors for entering <br /> and exiting are provided4 <br /> NA C402.5.7 Vestibules Indicate locations of all building entrances and • <br /> exit-only doors provided with an air curtain in <br /> lieu of a vestibule4 <br /> C402.5.7 Vestibules Indicate exception and criteria utilized for all <br /> • <br /> • building entrances and exit-only doors that do <br /> not have a vestibule or air curtain4 <br /> C402.5.7 Vestibules Indicate required performance for air curtains <br /> installed per Exception 74 <br /> • <br /> C402.5.7 Vestibules For unconditioned vestibules,indicate which <br /> envelope assembly(interior or exterior) <br /> • complies with the requirements for a <br /> conditioned space4 • <br /> NA C103.2 Building enclosure air Indicate in project documents that building <br /> • <br /> • <br /> C402.5.1.2C leakage test enclosure air leakage testing is required for <br /> 402.5.1.2.1 WSEC compliance4 <br /> R402.4.1.2 <br /> NA C103.2 Building enclosure air Provide area calculations that account for all <br /> C402.5.1.2C leakage test six sides of the air barrier boundaries4 <br /> 402.5.1.2.1 <br /> R402.4.1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.