My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
405 RIVERSIDE RD PODS 2021-09-28
>
Address Records
>
RIVERSIDE RD
>
405
>
PODS
>
405 RIVERSIDE RD PODS 2021-09-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/28/2021 1:51:53 PM
Creation date
9/24/2021 1:54:59 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
405
Tenant Name
PODS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 f • . it - • i - — ' 41 . - - - if ' • <br /> 2018 WSEC Requirements for Commercial B gs including Group R2,R3&R4 over 3 stories&all R1 dministered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br /> Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> f'>03..3.3 Addition of vertical Where the addition of new vertical <br /> fenestration 4 fenestration results in a window-to-wall ratio <br /> (vh'%y'R)exceeding the prescriptive maximum <br /> allowed C4024.1,demonstratemeth€d of ; <br /> compliance(prescriptive vertical fenestration <br /> alternate,component performance with target <br /> area adjusttttettt for the alteration area and t <br /> e fisting to t€maiti areas cc>nzlaiaaed.or total <br /> building performance per(`4071:demonstrate <br /> for each space conditioning category <br /> separately <br /> (.'5)3.3.3 :Addition of skylights laVhere the addition of new,skylights results in; <br /> a skylight-to--roof ratio(SRR)exceeding the <br /> prescriptive maximum allowed per C402.4.1, <br /> demonstrate method of compliance <br /> :(component performance compliance with i <br /> ';target area adjustment for the alteration area <br /> and existing-to-remain areas combined,or <br /> dtoetaatlo busildain g3 ope;faosr opnac e po Cd.4iEit7n)i. <br /> n <br /> ._ category separately4 <br /> YES C 103.2 Change in space • Indicate envelope alteration thermal Cover Sheet <br /> C103.6.3 conditioning or performance compliance path(prescriptive or <br /> C503.2 occupancy component performance with 110% <br /> C505.1 compliance allowance);provide WSEC envelope <br /> documentation compliance reports4 <br /> 11 <br /> NA C103.2 Change in space If complying via total building performance <br /> C103.6.3 conditioning or with 110%allowance,provide a list of all <br /> C503.2C occupancy proposed envelope component types,areas <br /> 505.1 compliance - and U-values4 • <br /> documentation <br /> PROJECT CLOSE OUT DOCUMENTATION <br /> NO C103.6.3 Project close out Indicate in plans that project close out <br /> documentation documentation is required including <br /> requirements applicable calculations,WSEC envelope <br /> compliance reports,and fenestration NFRC <br /> , rating certificates4 <br /> J age"979' 1 \ <br />
The URL can be used to link to this page
Your browser does not support the video tag.