Laserfiche WebLink
10/11/2021 <br />City of Everett <br />Page 2 <br />10:59:23AM <br />A <br />INSPECTION <br />ACTIVITY REPORT <br />9/27/2019 <br />9/27/2019 <br />BLDG <br />KMK <br />CORRECTION <br />(9/27/2019 3:25 PM KMK) <br />08-FRAMING <br />Add full blocking between floor joists at <br />bearing points. <br />10/2/2019 <br />10/2/2019 <br />BLDG <br />KMK <br />PARTIAL APPR <br />(10/2/2019 12:03 PM KMK) <br />08-FRAMING <br />1. Exterior stairs are not per plan. Change <br />or resubmit for review. <br />2. Verify with engineer post/beam <br />connections <br />3. Verify egress windows in bedrooms <br />downstairs (currently covered with <br />plywood) <br />Recall for interior shear walls <br />10/9/2019 <br />10/9/2019 <br />BLDG <br />KMK <br />APPROVAL <br />406-390-3676 <br />10-INTERIOR <br />AM -MID morning requested <br />(10/9/2019 3:27 PM KMK) <br />kmk changed Inspection Type from BLDG <br />08-FRAMING to BLDG 10-INTERIOR <br />SHEAR <br />11/4/2019 <br />11/4/2019 <br />BLDG <br />KMK <br />PARTIAL APPR <br />AM inspection requested <br />09-DRYWALL <br />(11/4/2019 1:33 PM KMK) <br />Party wall drywall ok (2 layers) <br />4/13/2020 <br />4/13/2020 <br />PERMIT <br />KLC <br />APPROVAL <br />Due to COVID-19 <br />EXTENSION <br />6/9/2020 <br />6/9/2020 <br />MECH 06-FINAL <br />SDP <br />CORRECTION <br />eTRAKiT Inspection <br />6/8/2020 8:55 PM Clete Messerly <br />Request <br />building inspection for 3714 & 3712 on <br />6/11/20 <br />Contact Name: Clete Messerly <br />Site Address: 3710 COLBY AVE <br />Phone:4063903676 <br />e-Mail: cxm820@gmail.com <br />(6/9/2020 3:00 PM SDP) <br />1) Tankless water heater is missing the <br />install kit which includes the T&P, unions, <br />shutoff and drain ports. Please install per <br />the manufacturers specs. <br />2) Condensate must be plumbed to an <br />approved location using proper methods <br />and materials. <br />3) Condensate for the ductless heat pump <br />must be plumbed using proper methods and <br />materials, collapsible pipe is not allowed to <br />be installed in any wall or building cavity. <br />6/9/2020 <br />6/9/2020 <br />PLUMB 06-FINAL <br />SDP <br />APPROVAL <br />eTRAKiT Inspection <br />6/8/2020 8:55 PM Clete Messerly <br />Request <br />building inspection for 3714 & 3712 on <br />6/11/20 <br />Contact Name: Clete Messerly <br />Site Address: 3710 COLBYAVE <br />Phone:4063903676 <br />e-Mail: cxm820@gmail.com <br />6/9/2020 <br />6/9/2020 <br />GAS 03-FINAL <br />SDP <br />APPROVAL <br />6/11/2020 <br />6/11/2020 <br />MECH 06-FINAL <br />SDP <br />APPROVAL <br />eTRAKiT Inspection <br />6/10/2020 5:32 PM Clete Messerly <br />Request <br />request afternoon inspection <br />Contact Name: Clete Messerly <br />Site Address: 3710 COLBY AVE <br />Phone:4063903676 <br />e-Mail: cxm820@gmail.com <br />INSP12 <br />