Laserfiche WebLink
Element 1. Preserve vegetation/mark clearing limits: <br />❑ BMP C101: Preserving Natural Vegetation <br />❑ BMP C102: Buffer Zones <br />X BMP C103: High Visibility Plastic or Metal Fence <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 2. Establish construction: <br />X BMP C105: Stabilized Construction Entrance/Exit <br />❑ BMP C106: Wheel Wash <br />❑ BMP C107: Construction Road/Parking Area <br />Stabilization <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 3. Control flow rates: <br />❑ BMP C203: Water Bars <br />❑ BMP C240: Sediment Trap <br />❑ BMP C241: Temporary Sediment Pond <br />❑ Other Per the SWMMWW: <br />X Not applicable to my proposed project <br />Explain: Stormwater runoff will be dispersed and not <br />concentrated into any one location <br />0 <br />❑ BMP C235: Wattles <br />❑ BMP C240: Sediment Trap <br />❑ BMP C241: Temporary Sediment Pond <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 5. Stabilize soils: <br />❑ BMP C120: Temporary and Permanent Seeding <br />❑ BMP C121: Mulching <br />❑ BMP C122: Nets and Blankets <br />X BMP C123: Plastic Covering <br />❑ BMP C124: Sodding <br />❑ BMP C125: Topsoiling/Composting <br />❑ BMP C126: Polyacrylamide for Soil Erosion <br />Protection <br />❑ BMP C130: Surface Roughening <br />❑ BMP C131: Gradient Terraces <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 6. Protect slopes: <br />❑ BMP C120: Temporary and Permanent Seeding <br />❑ BMP C130: Surface Roughening <br />❑ BMP C131: Gradient Terraces <br />❑ BMP C200: Interceptor Dike and Swale <br />❑ BMP C201: Grass -Lined Channels <br />❑ BMP C203: Water Bars <br />❑ BMP C204: Pipe Slope Drains <br />I� <br />❑ BMP C205: Subsurface Drains <br />❑ BMP C206: Level Spreader <br />❑ BMP C207: Check Dams <br />❑ BMP C208: Triangular Silt Dike (Geotextile Encased <br />Check Dam) <br />❑ Other Per the SWMMWW: <br />X Not applicable to my proposed project <br />Explain: The site slope is minimal <br />Element 7. Protect drain inlets: <br />❑ BMP C220: Storm Drain Inlet Protection <br />❑ Other Per the SWMMWW: <br />X Not applicable to my proposed project <br />Explain: No storm sewer inlets near the project site <br />Element 8. Stabilize Channels and Outlets: <br />❑ BMP C202: Channel Lining <br />❑ BMP C 209: Outlet Protection <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: No channels or outlets on -site <br />Element 9. Control pollutants: <br />X BMP C151: Concrete Handling <br />❑ BMP C152: Sawcutting and Surfacing Pollution Prevention <br />❑ BMP C153: Material Delivery, Storage, and Containment <br />❑ BMP C154: Concrete Washout Area <br />❑ BMP C250: Concrete Stormwater Chemical Treatment <br />❑ BMP C251: Construction Stormwater Filtration <br />❑ BMP C252: High pH Neutralization Using CO2 <br />.... ........... <br />'GRAVEL CONSTRUCTION ACCESS (BMP C105)!, <br />TESC PLAN <br />1 /16" = V-0" <br />P� <br />F5w <br />UJI <br />zLU <br />°- <br />o <br />m IL <br />Z <br />0 U) <br />�w <br />00 <br />C Z <br />I <br />❑ BMP C253: pH Control for High pH Water <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 10. Control dewatering: <br />❑ BMP C236: Vegetative Filtration <br />❑ Other Per the SWMMWW: <br />X Not applicable to my proposed project <br />Explain: Stormwater runoff will be dispersed and not <br />concentrated into any one location <br />Element 11. Maintain BM Ps: <br />X BMP C150: Materials On Hand <br />❑ BMP C160: Certified Erosion and Sediment Control <br />Lead (CESCL not required on -site for <1acre). <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 12. Manage the Project: <br />X BMP C150: Materials On Hand <br />❑ BMP C160: Certified Erosion and Sediment Control <br />Lead (CESCL not required on -site for sites <1 acre) <br />❑ BMP C162: Scheduling <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />Element 13. Protect low impact development: <br />❑ BMP C102: Buffer Zones <br />X BMP C103: High Visibility Plastic or Metal Fence <br />❑ BMP C200: Interceptor Dike and Swale <br />❑ BMP C207: Check Dams <br />❑ BMP C208: Triangular Silt Dike (Geotextile Encased <br />Check Dam) <br />❑ BMP C231: Brush Barrier <br />X BMP C233 Silt Fence <br />❑ BMP C 234: Vegetated Strip <br />❑ Other Per the SWMMWW: <br />❑ Not applicable to my proposed project <br />Explain: <br />/ 1 — — — — — — <br />I" <br />HIGH -VIZ <br />PLASTIC FENCE <br />(BMP C103) <br />I ,,I <br />CONC. WASH -OUT ONLY <br />WITHIN FOUNDATION WALLS <br />(BMP C151) <br />PLASTIC COVE <br />STOCK PILE (B <br />0 <br />ACCCESSORY <br />BUILDING SITE <br />I <br />I <br />SILT FENCE <br />(BMP C233) <br />r— —__1I l <br />RING OVER ' 'I <br />MP C123) <br />L - A <br />ANDREW <br />STEWART <br />ARCHITECT <br />11300 3rd Avenue NE Apt 340 <br />Seattle, Washington 98125 <br />405.808.5410 <br />andrew.keith.stewart@gmail.com <br />!3 <br />REGISTERED <br />ARCHITECT <br />kW MT.STHWART <br />OF WASHINGTON <br />MAINTAIN ADDITIONAL I BUILDING <br />0 <br />0 <br />N <br />0 <br />Z <br />U <br />a� <br />'o <br />a <br />CO <br />0 <br />N N <br />> CO <br />0 <br />0 <br />Lo W <br />SEDIMENTATION <br />PERMIT <br />CONTROL MATERIALS <br />5/14/2020 <br />ON -SITE (BMP C150) <br />REVISIONS <br /># DATE DESCRIPTION <br />s <br />C)FITY <br />EVE:RET <br />TESC PLAN <br />e� <br />A001 <br />