Laserfiche WebLink
r <br />' December 8, 2016 <br />Project No. T-7388-1 <br />Potential long-term settlement due to secondary compression of the soft silt and clay layer may also occur. These <br />secondary settlements cannot be fully mitigated during the surcharge program. The magnitude of this settlement <br />will be greater in the early years diminishing with time. Estimated total settlement due to secondary compression <br />rrange up to a maximum of one -inch in 20 years. Approximately 50 percent of the total secondary settlement will <br />be differential in nature due to the varying thickness and compressibility characteristics of the silt and clay layer. <br />5.3 Excavations <br />All excavations at the site associated with confined spaces, such as utility trenches and lower building levels, <br />must be completed in accordance with local, state, or federal requirements. Based on current Washington <br />Industrial Safety and Health Act (WISHA) regulations, the upper fills and medium dense, native sands at the <br />project site would be classified as Group B soils. The soft silts and clays would be classified as Group C soils. <br />Accordingly, temporary excavations in Type C and Type B soils should have their slopes laid back at inclinations <br />no steeper than 1.5:1 (Horizontal:Vertical) and 1:1 (Horizontal:Vertical), respectively, from the toe to the crest of <br />the slope. If there is insufficient room to complete the excavations in this manner, or if excavations greater than <br />20 feet in depth are planned, temporary shoring to support the excavations may be required. Properly designed <br />and installed shoring trench boxes can be used to support utility trench excavations where required. <br />Groundwater should be anticipated within excavations extending below the existing fill into the native sands. If <br />the excavation only extends two to three feet below the groundwater table, the volume of water and rate of flow <br />into the excavation is expected to be moderate and are not expected to impact the stability of the excavations <br />when completed, as described. Conventional sump pumping procedures, along with a system of collection <br />trenches, if necessary should be capable of maintaining a relatively dry excavation for construction purposes. <br />Deeper excavations that will require worker entry will likely require pre -draining using deep pump wells or <br />closely spaced well points. <br />This information is provided solely for the benefit of the owner and other design consultants, and should not be <br />construed to imply that Terra Associates, Inc. assumes responsibility for job site safety. It is understood that job <br />site safety is the sole responsibility of the project contractor. <br />5.4 Foundations <br />The building may be supported on conventional spread footing foundations bearing on foundation subgrade <br />prepared as recommended in Section 5.2 of this report. Perimeter foundations exposed to the weather should <br />bear at a minimum depth of 1.5 feet below final exterior grades for frost protection. Interior foundations can be <br />constructed at any convenient depth below the floor slab. <br />' We recommend designing foundations for a net allowable bearing capacity of 2,500 pounds per square foot (psf). <br />For short-term loads, such as wind and seismic, a one-third increase in this allowable capacity can be used. As <br />noted earlier, following successful completion of the surcharge program, estimated primary consolidation <br />' settlement due to building loads are less than '/z-inch. Total long-term settlement due to continued creep <br />compression of the soft silt/clay layer is estimated to range up to a maximum of one -inch over a 20-year span, <br />with approximately 50 percent of the long-term settlement being differential in nature. <br />Page No. 7 <br />