My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 <br />2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 <br />Project Title: Snohomish County Medical Exami <br />Date 12/6/2017 <br />A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. <br />For Building Dept. Use <br />Fan System ID HVAC-1 <br />System Supply Fan <br />y pp y <br />Constant Volume (CV), Variable Air <br />Volume Hospital/Lab CV <br />Hospital/Lab <br />(VAV), or <br />Speed Control <br />system that qualifies for VA budget per <br />C403.2.11.1, Exception 1 <br />Compliance is based upon either the fan motor nameplate horse power <br />Com liance O tion <br />p p <br />Brake HP <br />(Option 1), the fan brake horsepower (Option 2), or C403.7 high efficieny <br />VA fan brake horsepower (10% less than Option 2). The bhp calculation <br />provides adjustments for special equipment per Table C403.2.11.1(2). <br />In Fan Equipment Schedule below, provide maximum design supply airflow <br />rate (CFM) of all supply fans serving the conditioned space in Fan <br />Fan System Supply <br />Equipment Schedule below. Fan System CFM Total is the supply airflow of <br />the handler design Additional <br />9,210 <br />central air at peak conditions. volumetric air <br />CFM Total <br />flow provided at zone fan terminals, booster fans, or through induction is <br />not included in the supply CFM total. However, the fan power of this <br />equipment is included in the HP and BHP calculations. Fan System <br />Supply CFM Total is automatically calculated by the form. <br />Fan Equipment Schedule <br />Total CFM <br />Total Nameplate <br />Total BHP <br />Fan ID and Location <br />Fan Type <br />Quantity of Fan Type <br />(Note 1) <br />HP (Note 2) <br />(Note 3) <br />SF-1 <br />Supply <br />1 <br />9,210 <br />15 <br />9.3 <br />EF-1 <br />Exhaust <br />1 <br />10,010 <br />15 <br />10.5 <br />Note 1 - Total CFM is the maximum CFM of the listed fan(s) when Total Proposed: 30.0 19.8 <br />operating at peak design operating conditions. <br />Note 2 - Total namplate hp of the listed fan(s). Total Allowance: 13.8 25.2 <br />Note 3 - Total brake horsepower (bhp) of the listed fan(s) at peak <br />design operating conditions. Not required <br />if Nameplate HP compliance option chosen. Compliance Message: COMPLIES <br />Brake Horsepower Allowance Adjustments <br />Assigned Pressure <br />CalculatedAdjustment, <br />Device Type <br />Description and Location <br />CFM thorough this <br />Drop, PD in w.c. <br />Pressure Drop, <br />A in bhp <br />device (CFMD) <br />(Note 6) <br />PD in w.c. <br />(Note 8) <br />(Note 7) <br />Fully ducted return and/or <br />exhaust, laboratory <br />10,010 <br />2.15 <br />5.210 <br />Particulate filtration: MERV 13 - <br />9,210 <br />0.9 <br />2.007 <br />15 <br />Exhaust filters, scrubbers, or <br />10,010 <br />1 <br />2.423 <br />treatment <br />Energy recovery device, other <br />9,210 <br />1.09 <br />2.430 <br />than coil (Notes 4 & 5) <br />Particulate filtration: MERV 9 - <br />12 <br />9,210 <br />0.5 <br />1.115 <br />Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): <br />nl.n n...n nn IMn /`CAII :.. L... ... ..... ..F f•L... .., ,....1.. /GA .-....J ... L.... ...IGII A :F I..f t. .,..aL-.. ....L <br />13.18 <br />o, ov u U — fV - U10 JUlll VI L11V JUFI'./ly 1. Vl d11V VAIId UJ( li IVl If VVLII yV uuvuyn <br />the device. <br />Note 5 - Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply <br />divided by the enthaply difference between the outdoor air and return air at design conditions. <br />Note 6 -Assigned pressure drop (PD) adjustment per Table C403.2.11.1(2). <br />Note 7 - Pressure drop (PD) adjustment shall be calculated per the applicable method <br />defined in Table C403.2.11.1(2) based on specific system conditions. <br />Note 8 - A = PD ' CFMD14131 where A is the allowed system brake horse power <br />adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. <br />
The URL can be used to link to this page
Your browser does not support the video tag.