My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Snohomish County Courthouse Renovation (Date 5/11/2018 <br /> S <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> MOTORS&TRANSFORMERS <br /> In Spec Section <br /> Include electrical transformer schedule on electrical plans; 262200-Low <br /> Yes C405.6 Electrical tranformers indicate transformer size,efficiency,or exception taken Voltage <br /> Transformers <br /> Dwelling unit Indicate on electrical plans that each dwelling unit in Group R-2 <br /> NA C405.7 electrical energy has a separate electrical energy meter <br /> consumption <br /> Electric motor Include all motors,including fractional hp motors,in electric <br /> Yes C405.8 motor schedule on electrical plans;indicate hp,rpm,rated E-1XX series <br /> efficiency efficiency,or exception applied <br /> For luminaires in each elevator cab,provide calculated average Provided by <br /> efficacy of combined fixtures that indicates efficacy is not less Elevator <br /> than 35 lumens per watt; Manufacturer <br /> Indicate rated watts per cfm for elevator cab ventilation fans do Provided by <br /> Yes C405.9.1 Elevator cabs Elevator <br /> not exceed 0.33 watts per cfm; Manufacturer <br /> Indicate automatic controls that de-energize lighting and Provided by <br /> ventilation fans when elevator is stopped and unoocupied for a Elevator <br /> period of 15 minutes or more Manufacturer <br /> Escalators and Indicate escalators comply with ASME A17.1/CSA B44; <br /> NA C405.9.2 moving walks automatic controls are configured to reduce operational speed <br /> to the minimum permitted when not in use <br /> NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided <br /> with a variable frequency regenerative drive <br /> Identify all controlled and uncontrolled receptables on electrical <br /> • plans in each space in which they are required;include E-1XX series <br /> receptacle configuration such as spacing between controlled <br /> Yes C405.10 Controlled and uncontrolled,duplex devices,etc; <br /> receptacles <br /> Indicate on plans whether the method of automatic control for E-1XX series and <br /> each controlled receptable zone is by occupant sensor or E-902 series <br /> programmable time-of-day control <br /> If"no"is selected for any question,provide explanation: <br /> End of Lighting, Motor&Transformer Permit Documents Checklist <br /> a <br />
The URL can be used to link to this page
Your browser does not support the video tag.