Laserfiche WebLink
2. The maximum occupant load sign for Jury Assembly room 2000 (and other Assembly <br />Occupancies) could not be located on the IG series sheets (no change from original comment). <br />5. Doors requiring panic devices — no change to door schedule for the doors listed in the original <br />comment. <br />6. Door 4600B should swing in the direction of travel (no change from original comment). <br />8. Updated Braille exit signs could not be found on sheets IG-201 and IG-202 (no change from <br />original comment). <br />9. Detail 7/L-312 does not appear revised (and spacing not specified). For 3/16" cable spaced at <br />4" on center with intermediate bars at 4' on center with 1/4"' guide holes, the cables need only <br />separate/deflect 1/32"' (each over 4� to be out of compliance. It is not clear that the spacing is <br />adequate, with a reasonable amount of deflection, to ensure that t a 4" sphere will not pass <br />through. <br />12a. The one -hour construction of the partition (listing/detail) should be identified on the plans <br />(not noted on the floor plans, wall section 3/A3.15 or enlarged stair plans on Sheet I-410). <br />12b. The condition noted in the original letter has not been addressed for the first story. <br />Accessibility <br />3. Vision light heights in doors on Sheet I-610 do not appear to have been revised. <br />In order for the processing of your application to continue, it will be necessary to provide the <br />Building Division with two new sets of revised construction documents reflecting the corrections <br />requested. Please include a response letter which indicates how the corrections were resolved. <br />All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br />Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br />Code (IMC), and/or the 2015 Washington State Energy Code (WSEC), as amended by the State <br />of Washington and adopted by the City of Everett. The current IBC referenced standard for <br />accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI <br />A117.1). Federal ADA regulations and standards may be more restrictive. <br />These comments address building issues only. Additional revisions or additions may be required <br />by other departments (such as Utilities, Traffic, Planning or Fire). All required submittals must <br />be of sufficient detail and information to ensure that the proposed structure will be constructed <br />in compliance with all adopted codes. <br />Sincerely, <br />Tony Lee <br />Building Official <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8813 • Page 2 <br />