My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Bob Egleston <br />Apgust 2, 2018 <br />Page 5�F <br />Structure Comment MKA Response <br />26. The comment asked for clarification that <br />different floor weights representing the new <br />and existing construction have been used. <br />Identify where the calculations verify these <br />weights. <br />27. This comment does not appear to be <br />addressed by the submitted calculations as <br />indicated. Please specify the pertinent <br />calculation pages. <br />28. This comment does not appear to be <br />addressed by the submitted calculations as <br />indicated. The plans do not appear to <br />include a structural element developing the <br />new building chord into the existing <br />diaphragm at Grid F/13. <br />This comment does not appear to be <br />addressed by the submitted calculations as <br />indicated. Please specify the pertinent <br />calculation pages. <br />MAGNUSSON <br />KLEMENCIC <br />ASSOCIATES <br />The various structural system weights noted on <br />pages 4014-4021 of the previously submitted <br />calculations are divided by the gravitational <br />constant 32.2 ft/s2 to determine the applied floor <br />mass input in ETABS. <br />Refer to Section 5 (PDF page 178-184) of the <br />previously submitted calculations. Collector and <br />chord forces were all increased by 1.25. Please <br />note that in the calculations, this 1.25 factor was <br />mistakenly called rho and was either applied to <br />the demand force or required minimum area for <br />each condition. <br />Refer to section 5 of the previously submitted <br />calculations (PDF page 176 & lower half of page <br />184). The total chord force to be developed is <br />small (30k). The (2) #6 chord bars along grid <br />12.1 are hooked into the Grid F shear wall. The <br />existing columns and C10 perimeter beam in the <br />existing building all are connected into the new <br />grid F shear wall with headed studs. See details <br />6 & 10/S-603 to see load path. The existing N-S <br />W16 beams are moment connected into the <br />columns which by inspection adequately <br />develops the demand chord force from the <br />building addition into the existing building. The <br />existing C 10 channels are also directly connected <br />to the existing diaphragm via new collector plates <br />(see details 10/S-601 & 13/S-601) which <br />provides additional redundancy for developing <br />the small chord force from the building addition. <br />Due to the notch in the southwest corner of the <br />addition slab, additional reinforcement was <br />added to adequately develop the chord <br />reinforcement into the grid F shear wall and <br />existing connected elements. See sheet S-261 for <br />revised diaphragm reinforcement plans. <br />Requested calculation is included in attached <br />supplemental calculations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.