Laserfiche WebLink
ABBREVATI10INS <br />< ANGLE CI CAST IRON OR ENCLOSED GL GLASS OR GLAZING LT LIGHT PNT PAINT SD SOAP DISPENSER OR TOP TOP OF PAVEMENT <br />CL CENTER LINE CJT CONTROL JOINT EWC ELECTRIC WATER COOLER GLBM GLU-LAM BEAM LWC LIGHT WEIGHT CONCRETE POL POLISH STORM DRAIN TOS TOP OF STEEL <br />E CHANNEL CLG CEILING EQ EQUAL GC GENERAL CONTRACTOR MAS MASONRY PR PAIR SECT SECTION TOSL TOP OF SLAB <br />0 DIAMETER OR ROUND CJ CONSTRUCTION JOINT EQPT EQUIPMENT EMERGENCY GND GROUND MATL MATERIAL PRCST PRECAST SF SQUARE FEET TOW TOP OF WALL <br />NUMBER OR POUND CLK CAULKING SHOWER/ GWB GYPSUM WALL BOARD MAX MAXIMUM PSF POUNDS PER SQUARE SHT SHEET TPD TOILET PAPER <br />d PENNY CLR CLEAR ESEW EYE WASH GYP GYPSUM MB MACHINE BOLT FOOT SHTG SHEATHING DISPENSER <br />1 PERPENDICULAR CMU CONCRETE MASONRY EST ESTIMATE HB HOSE BIB MDO MEDIUM DENSITY PSI POUNDS PER SQUARE SIG SOLAR INSULATED TPH TOILET PAPER HOLDER <br />ft PLATE UNIT EXH EXHAUST HBD HARD BOARD OVERLAY INCH GLAZING TPTN TOILET PARTITION <br />AB ANCHOR BOLT CNTR COUNTER EX EXPANSION HC HOLLOW CORE OR MDF MEDIUM DENSITY PT PRESSURE TREATED SIM SIMILIAR TS TUBULAR STEEL <br />AC ACOUSTICAL OR ASPHALT CO CLEANOUT EXST EXISTING HANDICAP FIBERBOARD PTD PAPER TOWEL SK SINK TV TELEVISION <br />CONCRETE COL COLUMN EXP EXPOSED HID HAND DRYER MECH MECHANICAL DISPENSER SLR SEALER TYP TYPICAL <br />A/C AIR CONDITIONING CONC CONCRETE EXT EXTERIOR HDR HEADER MEMB MEMBRANE PTD/R PAPER TOWEL SND SANITARY NAPKIN UL UNDERWRITERS <br />ACP ACOUSTICAL PANEL CONN CONNECTION FA FIRE ALARM HDWD HARD WOOD MTL METAL DISPENSER AND DISPENSER LABORATORY <br />ACT ACOUSTICAL TILE CONSTR CONSTRUCTION FB FLAT BAR HDWE HARDWARE MEZZ MEZZANINE RECEPTABLE SNR SANITARY NAPKIN LION UNLESS OTHERWISE <br />ADD ADDITIVE CONT CONTINUOUS FBD FIBER BOARD HM HOLLOW METAL MFR MANUFACTURER PTN PARTITION RECEPTACLE NOTED <br />ADH ADHESIVE CORR CORRIDOR FBO FURNISHED BY OTHERS HORIZ HORIZONTAL MH MAN HOLE PTR PAPER TOWEL SNT SEALANT UR URINAL <br />ADJ ADJACENT CPT CARPET FCIC FURNISHED BY HR HOUR MIN MINIMUM RECEPTABLE SPEC SPECIFICATION VAR VARIES <br />ADJT ADJUSTABLE CT CERAMIC TILE CONTRACTOR INSTALLED HT HEIGHT MIR MIRROR PVC POLYVINYL CHLORIDE SPGL SPANDREL GLASS VCT VINYL COMPOSITION TILE <br />AFF ABOVE FINISH FLOOR CTR CENTER BY CONTRACTOR HTG HEATING MISC MISCELLANEOUS PVMT PAVEMENT SO SQUARE VENT VENTILATOR <br />AGG AGGREGATE CTSK COUNTER SINK FCTY FACTORY HVAC HEATING/VENTILIATION/ MO MASONRY OPENING QT QUARRY TILE SS SOLID SURFACING VERT VERTICAL <br />AL ALUMINUM CY CUBIC YARD FD FLOOR DRAIN AIR CONDITIONING MTD MOUNTED R RISER SST STAINLESS STEEL VEST VESTIBULE <br />ALT ALTERNATE D DEEP, DEPTH FDN FOUNDATION HWH HOT WATER HEATER MULL MULLION RA RETURN AIR SSK SERVICE SINK VNR VENEER <br />AP ACCESS PANEL DBL DOUBLE FE FIRE EXTINGUSHIER ID INSIDE DIAMETER/ N NORTH RAID RADIUS STA STATION VR VAPOR RETARDER <br />APPROX APPROXIMATE DEPT DEPARTMENT FEC FIRE EXTINGUSHER DIMENSION NIC NOT IN CONTRACT RB RESILIENT BASE STC SOUND TRANSMISSION VWC VINYL WALL COVERING <br />ARCH ARCHITECTURAL DET DETAIL CABINET IG INSULATED GLASS NO/# NUMBER R&S ROD & SHELF CLASS W WEST <br />AWF ACOUSTICAL WALL FABRIC DIA DIAMETER FIN FINISH IN INCH NOM NOMINAL RD ROOF DRAIN STN STAIN W/ WITH <br />AWP ACOUSTICAL WALL PANEL DIAG DIAGONAL FL FLOOR INCL INCLUDE NRC NOISE REDUCTION RD/O ROOF DRAIN OVERFLOW STD STANDARD W/O WITHOUT <br />BD BOARD DIM DIMENSION FLG FLASHING INSUL INSULATION COEFFICIENT REBAR REINFORCING BAR STL STEEL WC WATER CLOSET <br />BETW BETWEEN DISP DISPENSER FLUOR FLUORESCENT INT INTERIOR NTS NOT TO SCALE REF REFERENCE, REFLECTED STOR STORAGE WD WOOD <br />BLDG BUILDING DMPF DAMPPROOFING FOC FACE OF CONCRETE INV INVERT OA OVERALL REFR REFRIGERATOR STRL STRUCTURAL WDO WINDOW <br />BLK BLOCK DN DOWN FOF FACE OF FINISH JAN JANITOR OBS OBSCURE REINF REINFORCED SUSP SUSPENDED WF WIDE FLANGE <br />BLKG BLOCKING DR DOOR OR DRAIN FOIC FURNISH BY OWNER JST JOIST OC ON CENTER REQ REQUIRED SV SHEET VINYL WG WIRE GLASS <br />BM BEAM DWR DRAWER INSTALL BY CONTRACTOR JT JOINT OD OUTSIDE DIAMETER/ REV REVISION SYM SYMMETRICAL WM WIRE MESH <br />BRG BEARING DS DOWNSPOUT F010 FURNISH BY OWNER KO KNOCK OUT DIMENSION RH RIGHT HAND OR ROBE SWC SPECIAL WALL COVERING WOM WALK OFF MAT <br />BOT BOTTOM DW DISHWASHER INSTALL BY OWNER KS KNEE SPACE OH OVERHEAD HOOK T TREAD WP WATER PROOF <br />BSMT BASEMENT DWG DRAWING FOS FACE OF STUD LAB LABORATORY OPH OPPOSITE HAND RESIL RESILIENT TB TOWEL BAR WPT WORKING POINT <br />BUR BUILT UP ROOF E EAST FPW FREEZE PROOF WALL LAM LAMINATE OPNG OPENING RIO ROUGH -IN ONLY T&B TOP & BOTTOM WR WATER RESISTANT <br />CAB CABINET EA EACH HYDRANT LAV LAVATORY OPP OPPOSITE RM ROOM T&G TONGUE & GROOVE WSCT WAINSCOT <br />CB CATCH BASIN EB EXPANSION BOLT FS FULL SIZE LB LAG BOLT PBD PARTICLE BOARD RO ROUGH OPENING TG TEMPERED GLASS WT WEIGHT <br />CBU CEMENTITIOUS BACKER EJ EXPANSION JOINT FT FEET LF LINEAL FOOT PERP PERPENDICULAR RT RESILIENT/RUBBER TILE THK THICK WWF WELDED WIRE FABRIC <br />UNIT EIFS EXTERIOR INSULATED FTG FOOTING L LONG, LENGTH PL PLATE OR PROPERTY RUB RUBBER THR THRESHOLD XFMR TRANSFORMER <br />CEM CEMENT EL FINISH SYSTEM FURR FURRING LG LAMINATED GLASS LINE RWL RAIN WATER LEADER TIG TEMPERED INSULATED YD YARD <br />CER CERAMIC ELEC ELEVATION FUT FUTURE LH LEFT HAND PLAM PLASTIC LAMINATE S SOUTH GLAZING <br />CFM CUBIC FEET PER MINUTE ELEV ELECTRIC GA GAUGE LL LIVE LOAD PLAS PLASTER SC SOLID CORE TKBD TACK BOARD <br />CG CORNER GUARD EMER ELEVATOR GALV GALVANIZED LMS LIQUID MARKING PWD PLYWOOD SCD SEAT COVER DISPENSER TO TOP OF <br />CHBD CHALK BOARD ENCL EMERGENCY ENCLOSURE GB GRAB BAR SURFACE PNL PANEL SCHD SCHEDULE TOC TOP OF CONCRETE <br />SYMBOLS ENERGY CODE <br />NORTH 1. ENERGY CODE COMPLIANCE: <br />COLUMN WAREHOUSE AREAS: SEMI-HEATED:THE HEATING SYSTEM OF THE <br />OLINE/GRID 1 REVISION/ CLOUDED AREA 1 DETAIL IDENTIFICATION/ PROJECT NORTH BUILDING SHALL NOT INCLUDE ELECTRIC <br />LINE A9.1 SHEET NUMBER RESISTANCE HEATING EQUIPMENT <br />MATCH LINE COMPLIANCE METHOD: COMPONENT A <br />LAO DOOR NUMBER ELEVATION A01 EXTERIOR GLAZED <br />DOOR NUMBER 1 OPENING NO. 2. INSULATION REQUIREMENTS: <br />IDENTIFICATION/ <br />A5.1 EQUIPMENT ROOF INSULATION: RIGID CONTINUOUS OVER DECK: R-30 <br />WORK POINT, CONTROL SHEET NUMBER EQ-1 <br />POINT OR DATUM POINT IDENTIFICATION WALL INSULATION: NONE <br />1� KEY NOTE PERIFINISH SKYLI�GHTR SLAB INSULATION: NONE <br />0.3 3\/ 3 SECTION IDENTIFICATION / OFFICE ROOM IDENTIFICATION/ PNT-1 IDENTIFICATION SECTIONAL DOORS: R-12 <br />1 WALL TYPE A3.1 SHEET NUMBER 101 NUMBER X FENCE LINE ROLL -UP DOORS: R-12 <br />FIXED WINDOWS: U=0.32 <br />ENTRANCES: U=0.60 <br />3. SHADING COEEFICIENTS <br />SKYLIGHTS: SHGC=0.35 MAX. <br />FIXED WINDOWS: SHGC=0.40 MAX. <br />ENTRANCES: SHGC=0.40 MAX. <br />ZONING INFORMATION <br />1. Jurisdiction: EVERETT, WA <br />2. Present Zoning: M-1 - OFFICE AND INDUSTRIAL PARK <br />3. Projected site use requires: NO ACTION <br />4. Use Zone Adjacent Lots: N M-1 E M-1 S M-1 W M-1 <br />5. Special Regulations Applicable: <br />A. Shoreline Management Act Yes No X <br />Setback required B. Flood Plain or Waterway Yes No_ X <br />C. Airport open use/glide path Yes No X <br />D. Storm Water Retention/Run-Off Yes No X <br />E. Fire Lane Requirements No X <br />6. Setbacks <br />Required: Front Yard 30' Rear Yard 15' <br />W Side Yard 15' E Side Yard 30, <br />7. Easements, Vacations, restrictive convenants as applicable: <br />SEE CIVIL DRAWINGS <br />8. Parking <br />Building Shell (Office space area is speculative) <br />Office 7,500 SF 2.5 Stall/1,000 SF 18.8 Stalls <br />Warehouse (90%) 67,873 SF 1 Stall/1,000 SF 67.9 Stalls <br />Parking Stalls Required 4 Accessible 1 Van) 63 Parking 67 Total <br />Parking Stalls Provided 5 Accessible I Van) 106 Parking 111 Total <br />Standard: SIZE: 9'-0" x 18'-6" <br />Compact: <br />9. Total Site Area 189,310 SF 4.35 Acres <br />Landscaping Required: 20% 37,862 SF <br />Landscaping Provided: 22% 41,193 SF <br />GENERAL NOTES <br />INDEX OF DRAWINGS <br />ARCHITECTURAL <br />1. DIMENSIONS ARE TO FACE OF STUD, CONCRETE OR CENTER LINE OF COLUMN, <br />UNLESS OTHERWISE NOTED. <br />- COVER <br />G1.1 GENERAL INFORMATION <br />2. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. <br />A1.1 SITE PLAN <br />A2.1 FLOOR PLAN <br />3. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ARCHITECT <br />A2.2 FLOOR PLAN <br />OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. <br />A2.3 ROOF PLAN <br />0 PES, WALL TYPES, OPENING SCHEDULES <br />4. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE 3 <br />A3.2 ENLARGED FLOOR PLANS, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS <br />WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS <br />EXTERIOR ELEVATIONS <br />CANNOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT. <br />A4.2 ENLARGED EXTERIOR ELEVATIONS <br />A4.3 WALL SECTIONS <br />5. VERIFY ELEVATIONS & LOCATIONS TO BE JOINED BEFORE CONSTRUCTION, CONTACT <br />A4.4 WALL SECTIONS <br />ARCHITECT IF THEY DIFFER FROM THOSE SHOWN ON DRAWINGS. <br />A8.1 EXTERIOR DETAILS <br />6. ALL ROUGH -INS TO BE APPROVED PRIOR TO FRAMING INSPECTION. <br />STRUCTURAL <br />7. MECHANICAL, ELECTRICAL, AND PLUMBING ARE BIDDER DESIGN. PORTIONS OF THIS <br />S1.0 GENERAL NOTES, SPECIAL INSPECTIONS, ABBREVIATION LIST <br />WORK SHOWN ON DRAWINGS IS FOR DESIGN INTENT OR FOR COORDINATION ONLY. <br />S1.1 FOUNDATION SECTIONS <br />S2.0 FOUNDATION PLAN <br />8. MECHANICAL DESIGN/BUILD CONTRACTOR SHALL PROVIDE A MECHANICAL <br />S2.1 ROOF FRAMING PLAN <br />VENTILATION SYSTEM CAPABLE OF SUPPLYING THE MINIMUM OUTDOOR AIR <br />S3.0 SCHEDULES, DIAGRAMS <br />QUANTITIES SPECIFIED IN THE 2015 IMC WITH WASHINGTON AMENDMENTS. <br />S5.0 ROOF FRAMING SECTIONS <br />S5.1 ROOF FRAMING SECTIONS <br />9. ELECTRICAL DESIGN/BUILD CONTRACTOR SHALL PROVIDE AND INSTALL MEANS OF <br />S6.0 P.C. PANEL CONNECTIONS, REINFORCING DETAILS, NOTES & <br />PANEL PLACEMENT KEY <br />EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS PER IBC SECTIONS 1006 AND <br />S6.1 P.C. PANEL ELEVATIONS <br />1011. <br />S6.2 P.C. PANEL ELEVATIONS <br />S6.3 P.C. PANEL ELEVATIONS <br />10. BUILDING TO BE PROVIDED WITH AN NFPA 72 MONITORED FIRE ALARM. <br />S6.4 P.C. PANEL ELEVATIONS <br />S6.5 P.C. PANEL ELEVATIONS <br />11. BUILDING SHALLHAVE AN ESFR SPRINKLER SYSTEM. <br />S6.6 P.C. PANEL ELEVATIONS <br />12. ENSURE SPRINKLERS AND PIPING DO NOT INTERFERE DIRECTLY UNDER SKYLIGHTS. <br />�fl <br />PROJECT I FO R ATI <br />13. DEFERRED SUBMITTALS: <br />q � <br />STRUCTURAL JOISTS <br />FIRE ALARM AND SPRINKLERS (INCLUDES UTILITY ROOMS) <br />2 <br />PROJECT SCOPE: NEW BUILDDNG <br />PROJECT ADDRESS: ASSOCIATED BLVD & <br />INDUSTRY ST <br />EVERETT, WA 982023 <br />BUILDING OWNER: JACOB DAVIS <br />10600 231ST WAY NE <br />REDMOND, WA 98053 <br />CODE I F R TI O ��pp dN <br />PROPERTY TAX NO.: 28040100302300, 28040100302400 <br />ARCHITECT: SYNTHESIS PLLC <br />Code Edition: 2015 IBC, 2015 IFC, 2015 IMC, 2015 UPC, 2015 WSEC (WAC 51-11), <br />12503 BEL-RED ROAD, SUITE 101 <br />BELLEVUE, WA 98005 <br />ICC/ANSI A117.1-2009; WASHINGTON STATE AMENDMENTS TO THE ABOVE <br />(425) 646-1818 <br />(WAC 51-50). <br />CONTACT: RANDY BROWN <br />Scope of Construct a 75,373 square foot industrial facility utilizing site cast <br />STRUCTURAL: SHUTLER CONSULTING ENGINEERS <br />Work: concrete tilt -up wall panels, a wood roof supported on composite <br />12503 BEL-RED ROAD, SUITE 100 <br />steel joists and girders with wood nailers and HSS columns. The <br />BELLEVUE, WA 98005 <br />facility is single story with a minimum clear height of 24'-0" above <br />(425) 450-4075 <br />finished floor. There will be a total of (14) 9'X10' dock high doors <br />CONTACT: JOHN HEADLAND <br />and (2) 14' X 14' grade access doors. The facility is fully sprinklered <br />with an ESFR system. <br />Amended by Local Jurisdiction Yes X No Date <br />Construction: <br />New X Basic Wind Speed 110 MPH <br />Addition Seismic Use Group 1 <br />Alteration Occupancy Category 2 <br />Repair Site/Soil Classification D <br />Snow Load 25 PSP <br />BUILDING CLASSIFICATION <br />A. Occupancy Classification (Section 302) I3 / S-1 <br />B. Type of Construction (Section 602) <br />1. Type of Construction III-D <br />2. Automatic Sprinklers Provided Yes X No <br />C. Location of Property (602.1) SEE SHEET A1.1 <br />Distance to Openings Openings Fire Resistance <br />Property Line Permitted Protected of Exterior Wall <br />(Table 705.8) (Table 705.8) (Table 601 & 602) <br />North 30' Feet Yes X No Yes_ No X NONE <br />East 30 Feet Yes X No Yes No X NONE <br />South 0 Feet Yes X No Yes No X NONE <br />West 6�9.5 Feet Yes X No Yes No X NONE <br />(Other) - Feet Yes_ No Yes_ No <br />D. Building Area (Section 506) <br />LEGAL DESCRIPTION <br />1. At , Tabular Area (Table 506.2) S-1 OCCUPANCY 70,000 SF <br />2. Frontage Increase (506.3) <br />Section 01 Township 28 Range 04 Quarter SW - LOT 2 MOUNTAIN VIEW BUSINESS <br />CENTRE DIV 4 BSP <br />W (Width of Open Space per 506.3.2) = 30 FT <br />REC UND AFN 200501105159 BEING PTN NW1/4 SW1/4 SD SEC <br />If (Increase due to Frontage) = <br />100[(F/P)-0.25](W/30) = 75 % <br />Section 01 Township 28 Range 04 Quarter SW - LOT 3 MOUNTAIN VIEW <br />BUSINESS CENTRE DIV 4 <br />BSP REC UND AFN 200501105159 BEING PTN NW1/4 SW1/4 SD SEC <br />3. NS, Tabular Area (Table 506.2) 17,500 SF <br />4. Aa , Allowable Area (506.2.1) <br />At + (NS x If)= 83,125 SF <br />5. Unlimited Building Area (507) <br />NORTH <br />- Section 507.3 - Section 507.4 - Section 507.5 - Section 507.5 <br />VICI I P <br />- Section 507.6 - Section 507.7 - Section 507.8 - Section 507.9 <br />- Section 507.10 - Section 507.11 - Section 507.12 - Section 507.13 <br />6. Actual Floor Area: 1st Flr: 75„373 SF Mezz: 0 SF Total: 75,373 SF <br />E. Allowable Height and Number of Stories (Table 504.3 & 504.4) <br />1. Tabular Building Height Allowed 75 Feet 3 Stories <br />MERRIL CREEK PKWY <br />2. Actual Building Height 37'-6" Feet 1 Stories <br />12503 Red Road, 101 <br />Beillevue, <br />1818 f 425 646 4141 <br />10600 231 ST WAY ICE <br />REDMOND, WASHINGTON <br />........................... <br />.............................. <br />.............................. <br />3 09 05 2019 CITY COMMENTS <br />A2 08 09 2019 CITY COMMENTS <br />1 04 29 2019 BUILDING PERMIT <br />ISSUE NO. DATE ITEM <br />Digitally <br />signed by <br />714 REGISTERED Randy Brown <br />ARCHITECT <br />i�- Date® <br />STATE OFAN ALLLEE WASHINOGTON 201 .0 a 5 <br />Z. <br />1 3:3 : 7 <br />-079 <br />............................... <br />RELEASE FOR: BUILDING PERMIT <br />.I .............................. <br />TITLE: GENERAL INFORMATION <br />. . . . . . . . . . . . . . . . . <br />. . . . . . . . . . . . . . . . . . . <br />DESIGNED BY: DRAWN BY: <br />REVIEWED BY: APPROVED BY: <br />DATE: 10 30 2018 <br />SHEET NO: G1.1 <br />PROJECT NO: 201822.01 .001 <br />................................ <br />OO 2018 SYNTFI€sISPLLC <br />