Laserfiche WebLink
20" CLEAR <br />OPENING <br />0 <br />CD o <br />z � <br />MINIMUM REQUIRED <br />NET CLEAR OPENING <br />AREA IS 53 S.F. <br />a <br />a� CD <br />OPENINGS AT THE <br />u z <br />GRADE FLOOR MAY BE <br />v o <br />REDUCED TO 5 S.F. <br />CD <br />MINIMUM SIZE WINDOW w z <br />FOR 20" CLEAR WIDTH z <br />0 <br />34" CLEAR OPENING <br />(30" IF ON <br />GRADE FLOOR) <br />Q CD <br />w z <br />J <br />w <br />MINIMUM SIZE WINDOW <br />FOR 24" CLEAR HEIGHT <br />WALL ASSEMBLY <br />(E) FLOOR ASSEMBLY <br />WINDOW PER <br />SCHEDULE <br />c� <br />SAWCUT CONCRETE <br />LLJ <br />r <br />SILL AS REQUIRED <br />o z <br />FOR NEW WINDOW <br />I <br />LU <br />j <br />BASEMENT LEVEL <br />" <br />� <br />I <br />I <br />^ <br />3" MIN <br />SCALE: 3/8"=1 ' -0" <br />11 <br />EGRESS <br />LIGHT WELL—\ <br />a <br />o w L EGRESS <br />� C-' n LANDING <br />xo Of <br />CONTRACTOR'S OPTION: <br />PROVIDE PER -MANUFACTURED <br />EGRESS WELL <br />4 HORIZONTAL TOP & BOTTOM <br />d- <br />+� i-FINISH GRA <br />LLJ <br />' 4" GRAVEL <br />0 <br />� J <br />Cxt <br />EGRESS <br />WINDOW <br />i <br />v <br />2 <br />o <br />a <br />° <br />A2:0 <br />��- <br />FINISH FLOOR <br />Cr <br />Li <br />TYPICAL @ (2) LOCATIONS: <br />BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL NOT HAVE LESS THAN ONE <br />CONNECT NEW CONC WALL TO (E) <br />° <br />OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR <br />FOUNDATION W/ EPDXY GROUTED 2 <br />MORE SLEEPING ROOMS, AN EMERGENCY ESCAPE AND RESCUE OPENING SHALT_ BE REQUIRED <br />LONG #4 BARS @ 12" OC HORIZOP <br />IN EACH SLEEPING ROOM. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY <br />EMBED 4" MIN INTO EXISTING <br />INTO A PUBLIC WAY, OR TO A COURT OR YARD THAT OPENS TO A PUBLIC WAY. <br />3'_0" <br />CONCRETE. PROVIDE MINIMUM OF <br />CLR <br />BAR EACH ® FOOTING AND WALL. <br />MINIMUM TI <br />OPENINGEGRESS <br />- <br />LIGHT <br />WELL PLAN <br />SCALE: 1 /2"=1 '-0" <br />1 1 /4" MIN <br />OR 2" MAX <br />C <br />a <br />C <br />L <br />0F.19 rina <br />WALL BRACKET AT <br />4'-0" OC MAX <br />2X BLKG <br />WOOD BALUSTER <br />SPACED AT 4" OC MAX <br />,4T OUTSIDE 0� ST,41R <br />U <br />TYPICAL HANDRAIL DETAIL <br />SCALE: 1 /2"=1 ' -0" <br />1 1 /4" MIN 1 1 /2" MIN <br />OR2"MAX <br />RETURN TO <br />WHERE SHC <br />SEE PLAN <br />� AT WALL <br />) SCALE: NITS <br />HANDRAIL AND GUARDRAILS SHALL BE CONSTRUCTED AS FOLLOWS: <br />GUARDRAILS SHALL NOT BE LESS THAN 36" IN HEIGHT. HANDRAILS SHALL <br />NOT BE LESS THAN 34" OR MORE THAN 38" IN HEIGHT ABOVE THE STAIR <br />NOSING. <br />OPEN RAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN <br />SUCH AS A 4" DIAMETER SPHERE CANNOT PASS THROUGH. <br />THE TRIANGULAR OPENINGS AT STAIR TREAD, RISER & BOTTOM SHALL BE <br />SUCH AS A 6" DIAMETER SPHERE CANNOT PASS THROUGH. <br />THE HANDRAIL CONSTRUCTION SHALL BE ABLE TO RESIST A LOAD OF 200 <br />LBS APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP RAIL. <br />THIS DIAGRAM ILLUSTRATES THE SPECIFIC REQUIREMENTS OF THE BUILDING <br />CODE AND IS ONLY AN AID FOR CONSTRUCTION <br />V <br />PLk,N <br />NOTE: HANDRAIL & INSTALLATION SHALL MEET <br />THE REQTS OF THE 2018 IRC. FOR SPECIFIC <br />CODE REQTS FOR GUARD & HANDRAILS SEE <br />DETAILS THIS PAGE <br />NOTE: <br />HANDRAIL <br />& <br />INSTALLATION SHALL <br />MEET <br />THE REQTS <br />OF <br />THE 2018 IRC: <br />TYPICAL HANDRAIL / GUARDRAIL DETAIL <br />SCALE: NITS <br />2)0 LBS ANY <br />DRECTION ANY <br />LOCATION <br />_j z <br />o_ <br />< <br />CD <br />o75 <br />4" SPHERE MAY NOT <br />PASS THROUGH <br />6" SPHERE MAY NOT <br />PASS THROUGH <br />„ ill L <br />SD CMD <br />177 <br /><I S®' 4 `� <br />SD <br />() <br />.� <br />BEDROOM <br />(E) <br />METER <br />(E) <br />(E) ��II GP III (E) <br />OFFICE <br />� POWDER; (�) <br />I BEDROOM <br />KITCEFIEN �J <br />�.' N <br />.3� (E) <br />% LIVING <br />LEGEND <br />(E) WALL TO REMAIN <br />NEW 2x WOOD FRAME CONSTRUCTION TO MATCH <br />EXISTING <br />I <br />SMOKE DETECTOR (IRC - SECTION R314) <br />SD <br />CARBON MONOXIDE DETECTOR (IRC - SECTION <br />CMD R315) <br />® EXHAUST FANS. MIN. 50 CFM FOR BATHROOM AND <br />LAUNDRY; MIN. 100 CFM FOR KITCHEN, WITH DIRECT <br />k�� VENT TO EXTERIOR <br />Nurn Burgess <br />Basement <br />Alteration <br />1020 Colby Ave <br />Everett, WA 98201 <br />Permit <br />Set <br />Date: Description: <br />4/5/21 Permit Intake <br />Project No.: 2016.00 <br />Drawn: <br />FLOOR PLANS <br />SCHEDULES <br />Sheet No: <br />A2,0 <br />