Laserfiche WebLink
I <br />I <br />eILIECOM �jl� ICA � I NS `AIRING COMPONENTS <br />— (COAXIAL ANTENNA CABLE) <br />GENERAL <br />A. ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO <br />WORK SMALL BE N 1A1AND OF STANDARD COMMERCIAL QUALITY. <br />B. CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER <br />TO Go NERAL CONDITIONS FOR THE LIST OF OWNER FURNISHED EQUIPMENT, <br />;;MATERIALS AND SUPPLIES FOR THESE ITEMS). THE CONTRACTOR IS RESPONSIBLE <br />FOR PICKUP AND DEL°VERY OF ALL SUCH MATERIALS <br />C. ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT <br />DOCUMENTS SHALL BE SUPPLIED BY THE CONTRACTOR. <br />MATERIALS: <br />A. COAXIAL. CABLE : <br />1. INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS <br />ANDEQUIPMENT EQUIPg SENT PER MANUFACTURER'S RECOMMENDATIONS <br />WITH COAXIAL_ CABLES SUPPORTED AT NO MORE THAN 3'-0" O.C. <br />VlEATH RPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND <br />EQUIPMIEN I PER MANUFACTURERS' URERS' REQUIREMENTS. TERMINATE <br />ALL COAXIA CABLE THREE (3) FEET IN EXCESS OF EQUIPMENT <br />LOCATION IUNLESS OTHERWISE STATED. <br />AL I._ COAX RIJN LENGTHS GREATER T! iAN 143 FEET SHALL BE 1-5/6" <br />AND IN 1 ENG T H LESS 1-HAN OR EQUAL TO 143 FEET SHALL BE 7/8". <br />ANTENNA AND COAXIA! CABLE, GROUNDING <br />A. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON <br />STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) <br />4. COAXIAL CABLE IDENTIFICAT ION <br />A. TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF <br />ANTENNA ENNA CABLING PLASTIC TAGS SHALL BE USED AT THE <br />FOLLOiI\i`sNG L.00A i IONS: <br />. FIRST L OCA T ION 1S AT THE END OF THE COAX NEAREST <br />THE ANT ENNA (WHERE THE COAXIAL CABLE AND JUMPER <br />ARE CONNECTED). <br />ED). <br />2. SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER <br />NEAR ; Il WAVEGUIDE ENTRY PORT. <br />B. USE ANDREVV CA BLEZ TIES (PT.# 27290) TO SECURE IDENTIFICATION TAGS. <br />5. TESTING <br />VERIZON WIRELESS SHALL PROVIDE A[ J INDEPENDENT TESTING AGENCY TO PERFORM THE <br />COAXIAL SWEEP TEST REPORT, THE CONTRACTOR IS TO PROVIDE CLIMBER / QUALIFIED <br />PERSONNEL. TO ASSIST IN ANY REPAIRS AND WEATHERPROOFING ONCE THE TEST IS <br />COMPLETE. THE fCON F RACTOR IS TO PROVIDE VERIZON WIRELESS A MINIMIM OF 43 HOURS <br />NOTICE PRIOR T O THE TIME OF THE S0AIE EP TEST. <br />ililLviiimi Oman stow <br />PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK <br />BOARD. <br />UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING <br />• UL ARTICLE .51: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL B SLIP-ON, SOLVENT <br />SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" <br />Ill WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE RGS, (OR PVC ENCASED IN ii RED <br />CONCRETE DtA. <br />CONDUIT USED INDOORS S► BD RIGID STEEL <br />`l STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL <br />STUBS -UPS, USE RIGID GALVANIZED. <br />WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. <br />'t• D DP __ PULLI • A <br />� ter•. A . . �� �`� � � <br />. �• � .�.�- ._.: � ._�. •�.:. • �. �.•.� � � ,.: !'.y.-..._ •mow• _; � =. , <br />ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS LPSv3 OR AS PER NOTE <br />6 ABOVE. <br />ugg <br />VERIFY THAT A _ UTILITY DOESEXCEED A.I.C. RATING OF THE PROVIDED EQUIPMENT <br />SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING <br />`•ACCEPTABLE <br />LWARM211#1101 - <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION <br />SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />ACCESSIt 0ONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT <br />EQUIPMENT <br />3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND <br />CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR <br />DAMAGE TO THE CONDUIT. <br />4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). <br />5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) <br />HIGH PRESS CRIMPS. <br />6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL <br />SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. <br />7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. <br />6. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS OTHERWISE <br />INDICATED. <br />9. GROUND RODS SHALLOR COPPER STEEL, - 10-FT. LONG (OR <br />OTHERWISE ON PLANS), AND SHALL BE DRIVEN VERTICALLY WITH THEIR Tops 18" BELOW FINAL GRADE <br />OR ! BELOW FROSTA DEPTH. <br />11. USE OF 900 BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 451, BENDS <br />CAN BE ADEQUATELY <br />SUPPORTED. <br />12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST <br />LINE. <br />13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'=3" FROM EQUIPMENT CONCRETE PAD, <br />SPREAD FOOTING, OR FENCE. <br />gFoolllip <br />A , - - <br />16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT <br />GROUNDING POINTS PROVIDED (2 MINIMUM) <br />WAVE <br />A R C H I T E C T U B E <br />1133 164TH STREET SW <br />SUITE 202 <br />LYNNWOOD, VIA 98087 <br />OFFICE: (425) 778-380Q . <br />JAY@NEWWAVEARCH.COM <br />DATE-. 2-9-21 <br />PREPARED Y� Y ML <br />APPROVED BYs JYS <br />SUBMITTALS <br />NO DATE DESCRIPTION <br />2-9-21 FINAL PERMIT <br />2-1-21 REVISED PERMIT <br />1-28-21 REVISED PERMIT <br />1-22-21 PRELIMINARY PERMIT <br />887 <br />REG�I TEHE® <br />lRQHITECT <br />JIM <br />`? gAA0000,o <br />'JAY Y. SEO <br />STA OF WASHINGTON <br />IT <br />SHEET TITLE <br />SHEET NUMBER <br />