Laserfiche WebLink
Permit#: B1803-011 <br />Site Address: 2939 COLBY AVE <br />GENERAL. NOTES M3BREVI ATI ON5 PROJECT DATA LBU I LD I NG AREA CALCULATI ON5 <br />I ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICAPLE BUILDING CODES AS REVISED AND ADOPTED BY <br />SNOHOM15H COUNTY AND AASHINSTON STATE AS WELL AS ALL APPLICABLE LOCAL CODES, ORDINANCES AND <br />STANDARDS. <br />2 THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS A1TH ALL REVISIONS, <br />ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES. <br />5 CONTRACTOR TO COORDINATE PHASING OF CONSTRUCTION AITH THE BUILDING OWNERS TO COORDINATE MATERIAL <br />STORAGE, ACCESS TO AND FROM THE WORK, TIMING OF AORK, SPECIAL CONSIDERATIONS OF N015Y OPERATIONS, <br />INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, ETC. <br />4 CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC., AND NOTIFY THE ARCHITECT OF <br />ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. <br />5 ALL ITEMS MARKED "N.I.G" ARE NOT PART OF THIS CONTRACT UNLESS OTHERWISE NOTED. <br />6 ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST RECOMMENDATION OR NRITTEN <br />DIRECTIONS. <br />1 DO NOT 50ALE DRAWIN65; DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF <br />ANY AND ALL DISCREPANCIES. <br />8 ALL DIMENSIONS ARE TO FACE OF STUD OR CENTERLINE OF COLUMN, OR FACE OF CONCRETE WORK LNLE55 <br />OTHERWISE NOTED. <br />g WHEN CLEAR DIMENSIONS ARE NOTED (CLR) THEY REFER TO CLEARANCE FROM FINISHED SURFACES. <br />10 WHERE CONSTRUCTION DETAILS ARE NOT SHOI^M OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE <br />THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CANNOT SE RESOLVED IN THIS MANNER, CONTACT THE <br />ARCHITECT PRIOR TO PROGEEDIN& WITH THE WORK. <br />II THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECTS WRITTEN <br />APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND INDEMNIFY AND HOLD THE ARCHITECT HARMLESS <br />FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. <br />12 WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN 51NOULAR, IT IS INTENDED THAT SUCH SHALL <br />APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. <br />13 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON <br />OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR <br />REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION <br />OF THIS WORK, <br />14 THE CONTRACTOR WILL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES. <br />15 ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A GLEAN (BROOM) CONDITION <br />AT ALL TIMES. <br />16 THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND <br />WORKERS AT ALL TIMES. <br />11 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE THE JOB <br />iS IN PROGRESS. <br />18 ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER COMPLETION, UNLESS OTHERWISE <br />SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S ARITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, <br />CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN <br />FIVE (5) DAYS AFTER NOTICE IS GIVEN. <br />Ig ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY <br />LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASES, SMOKE, VIBRATIONS, HAZARD OR OTHER CAUSES. <br />20 THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER, AND TOILET FACILITIES. IN COMBUSTIBLE <br />CONSTRUCTION, FIRE STOPPING AND DRAFT STOPPING SHALL BE INSTALLED TO GUT OFF ALL CONGEALED DRAFT <br />OPENING BOTH VERTICAL AND HORIZONTAL AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN <br />A TOP STORY AND A ROOF OR ATTIC SPACE; AND SHALL SUBDIVIDE ATTIC, SPACES, CONGEALED ROOF SPACES <br />AND FLOOR -CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE AND DRAFT STOPS SHALL BE MAINTAINED. <br />21 ALL DOWNSPOUTS AND DRAINS SHALL CONNECT TO THE STORM DRAINAGE SYSTEM. <br />22 ALL WORD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. <br />23 ALL METAL FASTENERS TO BE OF THE SAME MATERIAL AS THE METALS USED FOR FLASHING ETC. WHERE <br />CONNECTION OF DISSIMILAR MATERIALS OCCUR, PROVIDE ADEQUATE PROTECTION TO PREVENT DETERIORATION. <br />THE PROTECTION SHALL INCLUDE, BUT NOT BE LIMITED TO, AN INSULATION GOAT OF BITUMINOUS PAINT BETWEEN ALL <br />DISSIMILAR METALS. <br />24 GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO THE IBC. ALL EXPOSED GYPSUM BOARD TO HAVE METAL <br />EDGES AT ALL CORNERS AND WALL INTERSECTIONS. WATER-RESISTANT GYPSUM BOARD SHALL BE USED IN <br />RESTROOMS AND ALL YET AREAS UNLE55 NOTED OTHERWISE IN THE PLANS. <br />25 ALL GLASS AND GLAZING SHALL COMPLY WITH THE IBC AND THE US PRODUCT SAFETY COMMISSION. <br />26 ALL EXTERIOR &LASS TO MEET THE REQUIREMENTS SET FORTH IN THE WASHIN&TON STATE ENERGY GODS. PROVIDE <br />SCREENS ON ALL OPERABLE WINDOWS. <br />2'1 THE CONTRACTOR SHALL VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW <br />MANUFACTURERS. <br />26 POST THE STREET ADDRESS NUMBERS ON THE BUILDINGS) 50 AS TO BE VISIBLE TO THE PUBLIC. NUMBERS SHALL <br />BE LEGIBLE FROM THE STREET FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST. <br />2g AATER HEATERS SHALL BE PROVIDED WITH APRESSURE/TEMPERATURE RELIEF VALVE WITH A DRAIN LINE PLUMBED <br />TO THE OUTSIDE. UPC, SECTION 6063. <br />30 WATER HEATERS AND OTHER FUEL BURNING EQUIPMENT SHALL RECEIVE ALL COMBUSTION AIR FROM THE OUTSIDE. <br />UMG SECTION 101.2. <br />51 ALL SERVICE WATER PIPING AND PIPING WITHIN THE BUILDING TO BE INSULATED PER THE WASHIN6TON STATE <br />ENERGY CODE. <br />52 WATER HEATERS SHALL COMPLY WITH THE REQUIREMENTS OF ASHRAE g0-"M AND SHALL BE VENTED TO THE <br />EXTERIOR, INSULATION SHALL BE AS REQUIRED BY THE WASHINISTON STATE ENERGY CODE. STRAP ALL WATER <br />HEATERS PER U.P.G. SECTION 506.2 TO RESIST SEISMIC, ACTIVITY. <br />33 EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAME, OPENINGS BETWEEN WALL AND FOUNDATIONS, BETWEEN <br />WALLS AND ROOF AND BETWEEN WALL PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICES SERVICES <br />THROUGH WALLS, FLOORS, AND DOORS, AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE SHALL BE <br />SEALED, CAULKED, &ASKETED, OR WEATHER STRIPPED TO LIMIT AIR LEAKAGE AND ELIMINATE WATER PENETRATION. <br />54 ALL TEARS AND JOINTS IN BAIT INSULATION TO BE SEALED WITH TAPE. <br />35 VAPOR BARRIER SHALL BE INSTALLED ON THE WARM SIDE OF ALL EXTERIOR WALLS. <br />56 BUILDING SHALL COMPLY WITH AIR LEAKAGE CONTROL REQUIREMENTS OF THE WASHIN&TON STATE ENERGY. <br />37 CONTRACTOR SHALL COMPLY WITH LIGHTIN&/SAITCHINI6 AND LIGHTING POWER BU06ETS AS SPECIFIED IN THE <br />AASHINI&TON STATE ENERGY CODE. CONTRACTOR SHALL SUBMIT DRAWINGS FOR REVIEW AND APPROVAL BY <br />DEPT. OF LABOR AND IMXSTRIE5 AND OBTAIN ALL NECESSARY PERMITS. <br />58 REFLECTED CEILING PLANS ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. <br />3g ELECTRICAL / MECHANICAL AND PLUMBING SYSTEMS SHALL BE BIDDER DESIGN. EXACT LOCATIONS SHOULD BE <br />VERIFIED BY CONTRACTOR. <br />THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE COMMENCING ANY DEMOLITION. <br />5HORIN6 SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION, AND IN A MANNER SUITABLE TO THE WORK <br />SEQUENCE. SAWGUTTIN6 EX15TINS REINFORCING SHALL BE AS DIRECTED BY THE ENGINEER OF RECORD. DEMOLITION <br />DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING, <br />(INCLUDING DEMOLITION DEBRIS) ON AN EXISTING FLOOR SYSTEM TO 100 PSF. THE CONTRACTOR SHALL WEATHERIZE <br />EXISTING STRUCTURE DURING DEMOLITION AND CONSTRUCTION. THE CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING <br />HEATHER PROTECTION AND WILL REPLACE AND/OR RESTORE TO ORIGINAL CONDITION ANY DAMAGES AS A RESULT OF <br />A BREECH IN WEATHMATION. <br />L.F. <br />LINEAR FOOT, LINEAL FT. <br />0 <br />AT <br />LW <br />LIGHT HEIGHT <br />4 <br />AND <br />LVL <br />LEVEL <br />L <br />ANGLE <br />MAS <br />MASONRY <br />€ <br />CENTER LINE <br />MAX <br />MAXIMUM <br />® <br />COPYRIGHT <br />M.B.S. <br />METAL BUILDING SUPPLIER <br />° <br />DEGREE <br />MECH <br />MECHANICAL <br />0 <br />DIAMETER <br />MEZZ <br />MEZZANINE <br />= <br />EQUAL <br />MTL <br />METAL <br />> <br />GREATER THAN <br />MFG <br />MANUFACTURIN6 <br />< <br />L -55 THAN <br />MFR <br />MANUFACTURER <br /># <br />NUMBER <br />MH <br />MANHOLE <br />% <br />PERCENTAGE <br />MIN <br />MINIMUM <br />i <br />PLUS/MINU5 <br />M150 <br />MISCELLANEOUS <br />R <br />PLATE <br />M.O. <br />MASONRY OPENING <br />M.R. <br />MOISTURE RESISTANT <br />ABBREVIATIONS: <br />NIG <br />NOT IN CONTRACT <br />AB.E. <br />AVERAGE BUILDING <br />NOM <br />NOMINAL <br />ELEVATION <br />NTS <br />NOT TO SCALE <br />A/C <br />AIR CONDITIONER <br />OG <br />ON CENTER <br />ADJ <br />ADJUSTABLE, ADJACENT <br />O.H. <br />OVERHEAD <br />ADMIN <br />ADMIN15TRATION <br />OPP <br />OPPOSITE <br />AFF <br />ABOVE FINISH FLOOR <br />0/ <br />OVER <br />AF6 <br />ABOVE FINISH GRADE <br />(P) PROP. <br />PROPOSED <br />ALUM <br />ALUMINUM <br />PERP <br />PERPENDICULAR <br />ANOD <br />ANODIZED <br />PL <br />PLATE, <br />APPROX <br />APPROXIMATE <br />P-LAM <br />PLASTIC LAMINATE <br />ALT <br />ALTERNATE <br />PLUMB <br />PLUMBING <br />ASR <br />AUTOMATIC SPRINKLER <br />PNL <br />PANEL, PANELING <br />RISER <br />PROJ <br />PROJECT, PROJECTED <br />AV& <br />AVERAGE <br />PRV <br />PRESSURE REDUCING VALVE <br />BFF <br />BELOW FINISH FLOOR <br />PT <br />POINT <br />5F6 <br />BELOW FINISH GRADE <br />QTR <br />QUARTER <br />BLDG <br />BUILDING <br />R <br />RADIUS <br />B.O. <br />BOTTOM OF <br />RD <br />ROOF DRAIN <br />50T <br />BOTTOM <br />RL <br />RAIN LEADER <br />8TW <br />BETWEEN <br />REC'D <br />RECEIVED <br />GB <br />CATCH BASIN <br />REF <br />REFRIGERATOR, <br />0.1. <br />CAST IRON <br />REFERENCE <br />GIP <br />CAST IN PLACE <br />REINF <br />REINFORCING <br />CJ <br />CONTROL JOINT, <br />REQ'D <br />REQUIRED <br />CONSTRUCTION JOINT <br />RR <br />RESTROOM <br />GMU <br />CONCRETE MASONRY UNIT <br />RO <br />ROUGH OPENING <br />COL <br />COLUMN <br />ROA <br />PUBLIC R16HT OF WAY <br />GONG <br />CONCRETE <br />S.A.M. <br />SELF ADHESIVE MEMBRANE <br />CONT <br />CONTINUOUS <br />SCHED <br />SCHEDULE <br />DF <br />DRINKING FOUNTAIN <br />50 <br />SOLID GORE <br />DS <br />DOWNSPOUT <br />SD <br />STORM DRAIN <br />01% <br />DRAWING <br />SF <br />50ARE FOOTAGE, FEET <br />0, EXIST. <br />EXISTING CONDITION <br />S6 <br />SAFETY OLA59 <br />EA <br />EACH <br />5HT <br />SHEET <br />ELEV <br />ELEVATION, ELEVATOR <br />SIM <br />51MILAR <br />ELM <br />ELECTRICAL <br />SPEC <br />SPECIFICATION <br />EJ <br />EXPANSION JOINT <br />SQ <br />SQUARE <br />EQ <br />EQUAL <br />55 <br />STAINLESS STEEL, <br />EXIST <br />EXISTING <br />SAN <br />SANITARY SEVER <br />EJ <br />EXPANSION JOINT <br />STD <br />STANDARD <br />EXP <br />EXPANSION <br />STL <br />STEEL <br />EXT <br />EXTERIOR <br />STRUCT <br />STRUCTURE, STRUCTURAL <br />F.C.IL. <br />FURNISH BY CONTRACTOR, <br />SU5P <br />SUSPENDED <br />INSTALL BY CONTRACTOR <br />SYS <br />SYSTEM <br />FD <br />FLOOR DRAIN <br />T <br />TEMPERED, TREAD, TOP <br />FON <br />FOUNDATION <br />T45 <br />TOP $ BOTTOM <br />FF <br />FINISH FLOOR <br />TEL <br />TELEPHONE <br />FD.I.O. <br />FURNISHED BY OWNER, <br />TEMP <br />TEMPERED <br />INSTALLED BY OWNER <br />T46 <br />TONGUE 4 GROOVE <br />FEC <br />FIRE EXTINGUISHER CABINET <br />T& <br />TEMPERED GLASS <br />F.O.I.C. <br />FURNISHED BY OWNER, <br />T.O. <br />TOP OF <br />INSTALLED BY CONTRACTOR <br />TYP <br />TYPICAL <br />FT6 <br />FOOTING <br />UTIL <br />UTILITY <br />6A <br />GAUGE <br />U.N.O. <br />UNLE55 NOTED OTHERWISE <br />6ALV <br />GALVANIZED <br />VGT <br />VINYL COMPOSITION TILE <br />GC <br />GENERAL CONTRACTOR <br />VERT <br />VERTICAL <br />6W5 <br />GYPSUM WALLBOARD <br />A/ <br />WITH <br />H <br />HIGH, HE16HT <br />A/0 <br />WITHOUT <br />HB <br />H05E BIBS <br />A -MAT <br />WALK OFF MAT <br />HM <br />HOLLOW METAL <br />Ap <br />WATERPROOF <br />HORIZ <br />HORIZONTAL <br />AR <br />WATER RESISTANT <br />HT <br />HE16HT <br />YM <br />WATER RESISTANT BARRIER <br />INSUL <br />INSULATION <br />AT <br />HEIGHT <br />JT/JTS <br />JOINT,JOINTS <br />Aw <br />WELDED WIRE MESH <br />L <br />LONG, LENGTH <br />WWF <br />MELDED WIRE FABRIC <br />LAM <br />LAMINATE, LAMINATED <br />NAME OF PROJECT: <br />EVERETT MUSEUM OF HISTORY <br />DEMOLITION PERMIT <br />PROJECT LOCATION: <br />241M COLBY AVE. <br />EVERETT, WA 418201 <br />GOVERNING AUTHORITY: <br />CITY OF EVERETT <br />GOVERNING CODE: <br />2015 I.B.G. AS ADOPTED <br />BY THE CITY OF EVERETT <br />ENERGY CODE: <br />2015 INTERNATIONAL ENERGY <br />CONSERVATION CODE <br />AIR QUALITY CODE: <br />2015 VENTILATION AND <br />INDOOR AIR QUALITY CODE. <br />ZONING: <br />55 - CENTRAL BUSINESS DISTRICT <br />CONSTRUCTION TYPE: <br />V-B, FULLY SPRINKLERED <br />NUMBER OF STORIES: <br />2 <br />OCCUPANCY: <br />BUSINESS GROUP B (CURRENT) <br />CHANGE OF OCCUMANCY TO ASSEMBLY A-5 UNDER TENANT IMPROVEMENT) <br />PARCEL NUMBER: <br />006444168301500 <br />OWNER: <br />EVERETT MUSEUM OF HISTORY <br />2g3g COLBY AVE. <br />EVERETT, WA g8201 <br />ARCHITECT: <br />CAPITAL ARCHITECTS GROUP <br />2615 ROCKEFELLER AVE. <br />EVERETT, WA 018201 <br />FAX: (425) 51'1-848g <br />PHONE: (425) 311-60I"i <br />CONTACT: SANDRA HIGGINS <br />2015 INTERNATIONAL BUILDING CODE <br />2015 INTERNATIONAL EXISTING BUILDING GORE <br />1G6/ANSI A111.1-20001 STANDARD FOR ACCESSIBLE BUILDINGS <br />2015 INTERNATIONAL MECHANICAL CODE <br />2014 NATIONAL ELECTRIC CODE <br />2015 UNIFORM PLUMBING CODE <br />2015 INTERNATIONAL FIRE CODE <br />AUTOMATIC FIRE DETECTION $ SUPPRESSION SYSTEMS ORDINANCE <br />2015 INTERNATIONAL ENERGY CONSERVATION CODE <br />2015 WASHINGTON STATE ENERGY CODE <br />2015 INTERNATIONAL PROPERTY MAINTENANCE CODE <br />EVERETT MUNICIPAL CODE <br />ENERGY CODE <br />INFORMATION <br />2015 WASIN6TON STATE ENERGY CODE TABLE G402.1.3 <br />CLIMATE ZONE: 40 <br />ROOF: <br />ATTIC, AND OTHER: <br />R-44 <br />WALLS, ABOVE GRADE: <br />MASS: <br />R-415al <br />WOOD FRAMED: <br />R-21 <br />WALLS, BELOW GRADE: <br />MASS: <br />R-g.5c1 <br />WOOD FRAMED: <br />R-21 <br />FLOORS: <br />MASS: <br />R-30c1 <br />J015T / FRAMING: <br />R-50 <br />SLAB -ON -GRADE FLOORS: <br />UNHEATED SLABS: <br />R-10 FOR 24" BELOW <br />HEATED SLABS: <br />R-10 PERIMETER AND UNDER ENTIRE SLAB <br />DOORS - TABLE G402.1.4: <br />OPAQUE SWINGING: <br />U-051 <br />EXTERIOR WINDOW - METAL GLAD TABLE 0303.1.3(I): <br />SINGLE -PANE <br />U-.45 <br />DOUBLE -PANE <br />U-55 <br />TABLE 0402A <br />VERTICAL FENESTRATION <br />NONMETAL FRAMING <br />U-026 <br />METAL FRAMING (FIXED) <br />U-0.31 <br />SITE PLAN NTS <br />Qwner: <br />EVERETT MUSEUM OF HISTORY <br />Tenant: <br />EVERETT MUSEUM <br />App. Date: <br />3/7/2018 <br />Proposed Use: <br />COMMERCIAL <br />Description: <br />DEMO OF NON-STRUCTURAL WALLS/ ACT/ <br />PLUMBING FIXTURES FOR <br />R ed BY: <br />Qate: <br />Office Se <br />Iola Site Set Fire/Planning Set <br />2a3cl COLBY AVE. <br />EVERETT, NA 18201 <br />U <br />glq <br />rr'r��1 <br />V <br />M <br />+-j <br />.r.04 <br />��C�11 <br />V <br />�a 15 OCX FELLER AVE <br />LOWER FLOOR DEMO I. DEMO RESTROOM FIXTURES 4 PLUMBING WALL. EVERETT, �NA �a 20) <br />2. DEMO ELECTRICAL EQUIPMENT REMAINING FROM GENERATOR. F } ® 4 11. a O I -7 <br />3. DEMO OVERHEAD COILING DOORS. I <br />4. GLEAN d BRUSH DEBRIS OFF EXTERIOR MASONRY WALLS FOR WATERPROOFIN 6 SLURRY INSTALL. X : 42 I -fi .8 8 <br />5. DEMO INDICATED WALLS 4 DOORS. <br />MAIN FLOOR DEMO APR 0 9 2018 <br />I. DEMO RESTROOM FIXTURES d PLUMBING WALL. <br />2. DEMO ELECTRICAL EQUIPMENT REMAINING FROM GENERATOR. � <br />S. ENLARGE EXISTING GENERATOR SHAFT FOR ELEVATOR INSTALL.CITYOVERET <br />Services <br />4. DEMO INDICATED WALLS 4 DOORS. Permit <br />5. IWE-ST16ATION OF EXISTING SHAFTS FOR REMOVAL IF NO LONGER NEEDED. <br />6. INVESTIGATION OF EXISTING FLOOR PENETRATIONS FOR PATCH 4 REPAIR IF NO LONGER NEEDED. <br />1. DEMO COUNTER, SINK AND CABINETRY AT BREAK ROOM. <br />6. DEMO COUNTER AND RELOCATED DRY SPRINKLER SYSTEM AS NEEDED AT OFFICE 6. <br />LOWER FLOOR RGP DEMO C"CU aac'" t>ez <br />I. DEMO ALL ACT # DROP -IN LIGHT FIXTURES. <br />2. DEMO L16HT FIXTURES AT RESTROOMS. <br />MAIN FLOOR RGP DEMO <br />I. DEMO ALL ACT 8 DROP -IN LIGHT FIXTURES. <br />2. DEMO LIGHT FIXTURES AT RESTROOMS AND BREAK ROOM. <br />PROPOSED AREA LONER LEVEL 8pw SF <br />UPPER LELVEL 8,000 SF <br />TOTAL PROPOSED AREA 16,000 SF <br />DEFERRED SUBMITTALS <br />TENANT IMPROVEMENT, CHANGE OF USE, AND ENERGY ANALYSIS TO BE COMPLETED AT A LATER DATE. <br />DRAINING INDEX <br />ARCHITECTURAL <br />COVER, DRAWING INDEX, GENERAL NOTES <br />A -ID <br />A-2.0 <br />DEMOLITION LOWER LEVEL FLOOR PLAN <br />A-2.1 <br />DEMOLITION UPPER LEVEL FLOOR PLAN <br />A-22 <br />DEMOLITION LOWER LEVEL REFLECTED CEILING PLAN <br />A-2.5 <br />DEMOLITION UPPER LEVEL REFLECTED CEILING PLAN <br />VICINITY MAP <br />L-------------------------� <br />1 i <br />1 <br />I& 110' - <br />?LBY AVE. PRo�oSED <br />INTERIOR DEMO <br />ON EX 15T I NG 16,000 <br />'' 5E. BUILDIN& <br />WALL ST. <br />s <br />PROPERTY LINE <br />N PROPERTY CORNER <br />APPROVED <br />1 PLANNING & COMMUNITY <br />DEV L P ENT DEPT. <br />1 <br />BY <br />1 DATE <br />: <br />i <br />R <br />THESE DOCUMENTS HAVE NOT BEEN <br />APPROVED FOR THE ISSUANCE OF <br />PUBLIC WORK, MECHANICAL, FIRE <br />SUPPRESSION, ELECTRICAL OR <br />PLUMBING PERMITS <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />d <br />5720 REGISTERED <br />ITECT <br />SAN R <br />INGTON <br />50ALE: A5 NOTED <br />155UE DATE: 5/b/I8 <br />DRIAINN: 50/5M <br />CHECKED: 5H <br />@THIS PLAN AND DESICGN 15 AND REMAINS <br />THE PROPERTY OF THE ARCHITECTS AND <br />MAY NOT BE U5ED WITHOUT PRIOR <br />CONSENT FROM THE ARCHITECT <br />FOR DEMO PERMIT <br />COVER SHEET <br />