Laserfiche WebLink
WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAYE PREGEDENCE OVER SCALED DIMENSIONS. <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GONDITION5, ETC. PERTAINING TO THE WORK <br />BEFORE PROCEEDING. THE OWNER MUST BE NOTIFIED OF ANY VARIATIONS FROM THE <br />DIMEN5IONS AND/OR GONDITION5 SHOWN ON THESE DRAWIN65, ANY SUGH VARIATION SHALL BE <br />RESOLVED BY THE OWNER PRIOR TO PROCEEDING WITH THE WORK, OR THE GONTRAGTOR SHALL <br />AGGEPT FULL RESPON5IBILITY FOR THE C05T TO REGTIFY SAME. <br />W1070�,� <br />ALL BEAMS THAT ARE NOT WINDOW OR <br />DOOR HEADERS OR UNLESS CALLED OUT ON <br />THE PLANS ARE TO BE: EITHER 5EELOW PLATE <br />( TOP OF BEAM 15 FLUSH WITH THE: TOE' PLATE) <br />OR ABOVE PLATE ( THE BOTTOM OF THE BEAM <br />15 AT THE TOP PLATE: OR IN THE FLOOR SYSTEM) <br />ALL BEAM TO WALL OONNFC TIONS ARE TO USE <br />ySi& STRAPS FROM THE BEAM TO THE: SUPPORTING <br />STUDS OR POSTS <br />ALL BEAM HANGARS ARE: TO BE SIMPSON OR SIMILAR <br />APPROVED HANGARS. THE OONTRAGTOR 15 TO VERIFY <br />PRIOR TO GONSTRUGTION THE AVAILABILITY OF: HANGARS <br />GALLEDD OUT ON THE FLANS <br />USE OSI STRAPS FOR SPLIGEtD BEAM GONNEOTIONS <br />( AT 5UPPORTIN6z, POSTS) <br />�EME=-RAL NOTES <br />I. ALL EXTERIOR WARM WALL5 TO BE 2x6 STUDS <br />I69" O.G. TYPIGAL, WITH R-21 INSULATION. <br />2. ALL HEADERS ON UPPER FLOOR TO BE 4xb <br />DOUGLAS FIR #2 UNLE55 NOTED OTHERWISE. <br />3. FUR -OUT HEADERS TO MATCH 2xb WALLS. <br />4. PROVIDE SOLID BLOGKING UNDER ALL <br />BEARING WALLS. <br />S. INLINE FRAMING - SINGLE TOP PLATE <br />STRAP ® SPLICES AND CORNERS, EXCEPT <br />AS NOTED FOR SHEAR TRANSFER, <br />6. ALL GUARDRAILS PER MANUFAGTURERS <br />SPECIFICATIONS. SUPPORTS GAPABLE OF <br />RESISTING LATERAL LOAD OF 50 Ibs. PER <br />LINEAR FOOT APPLIED AT TOP OF RAIL. <br />`7. TUB/5HOWER UNITS SHALL HAVE FIRE BLOCKING <br />BETWEEN WALL STUDS AND WATERPROOF <br />SURROUNDS TO +-72" FROM DRAIN. GLAZING, <br />INGLUDING WINDOWS WITHIN +-12" OF DRAIN, SHALL <br />BE SAFETY 6LA55. SHOWER FLOW IS LIMITED TO <br />2.5 GAL/MIN, WOOD FRAMING TO BE PROTECTED <br />FROM WATER SPLASH AND MOISTURE. <br />8. ALL BATHROOM FANS, KITCHEN HOOD, AND DRYER <br />DUGTS SHALL BE EXHAUSTED THRU THE ATTIC TO <br />THE ROOF OR THRU THE FLOOR SYSTEM TO AN <br />OUTSIDE WALL. ALL WALL DUGTS SHALL <br />TERMINATE AT LEAST 36" FROM A WINDOW <br />OPENING. <br />q. ONE WINDOW PER BEDROOM SHALL MEET <br />EGRESS GODS. <br />10. UNDER ALL PARALLEL BEARING WALLS, USE <br />DOUBLE JOISTS OR AS NOTED ON PLAN. <br />DOUBLE JOIST UNDER ALL <br />NON --BEARING PARALLEL WALLS. <br />LE67E D <br />... <br />BEARING WALL <br />FLOOR LINE ABOVE <br />MULTIPLE 2x STUDS ® POINT LOAD <br />(2) 2x TYP. UNLESS NOTED OTHERWISE <br />PT. LE). <br />POINT LOAD ABOVE <br />ABV. <br />SMOKE DETECTOR IIOV <br />INTERCONNECTED W\ BATTERY <br />BAGK-UP. <br />GARBON MONOXIDE DETECTOR <br />INTERCONNECTED W\ BATTERY <br />BAGK-UP. <br />(5.6.) <br />SAFETY 6LA55 <br />VTO <br />VENT TO OUTSIDE <br />FAN ® VENT TO OUTSIDE <br />50 GFM MINIMUM <br />4X4 POST AT GIRtDER TRUSSES, HIP <br />MASTERS, OR BEAM ENDS OR USE (5) <br />WHERE LARCGE:R POSTS ARE <br />GALLED OUT, AN EOUAL WIDTH OF 2X(4)65 <br />MAY BE USED ( IF A &Xe> POST 15 REOUIREID <br />THAN USE (4) 2X&) <br />USE 2 STUDS AT EACH WINDOW CRIPPLE`. <br />SEE SHEET Ll FOR SHEAR WALL <br />NAILING 5GHEDULE, 4 DETAILS. <br />SHWA <br />PI-61, INDICATES SHEAR WALL <br />REFER TO SCHEDULE <br />INDICATES 3x FRAMINO <br />(ax) MEMBERS; MUD 51LL's, PLATE'S <br />4 STUDS @ EDGES. <br />_ - y <br />