Laserfiche WebLink
WindermerePropertyManagement <br />OCCUPANCY LOAD CALL <br />NET HABITABLE SQUARE FOOTAGE- 3088 SF <br />OCCUPANCY GROUP: BUSINESS GROUP- 13" <br />BUSINESS - OCCUPANCY LOAD FACTOR = 100 GROSS <br />PER 2015 IBC- TABLE 1004. 1 .2 <br />OCCUPANY LOAD : 3088 / 100 = 30.65...OR 30 <br />PROPOSED NUMBER OF EMPLOYEES: 17 <br />WALL LEGEND <br />EX15TING INTERIOR NOiN-LOAD BEARING <br />p` 5HEA2 WALL <br />- 2Xo WD STUDS @ ! o'O.C. <br />-7/ 1 G' 055 5HF_ATl-1INlG ON (1) SIDE <br />® NEW NEW NON -LOAD SEARING PARTITION WALL- <br />-METAL 5TUD5, 5OUND,IV5ULATION, _' TYPE 1XII <br />GWD EACLI SIDE AND DRACING TO U,NDER5IDE <br />OF ROOF STRUCTURE. <br />-5FF 1/A2. 1 FOR WALL SECTIONS. <br />1) EXISTING EXTERIOR WALL5 OF BUILDING TO REMAIN A5 15 (NO CHANGE). <br />ALL NEW INTERIOR WALL5 TO BE NON -LOAD BEARING. <br />2) 5EE STRUCTURE FOR DETAILS REQ'D TO ACCOMMODATE NEW OPENING/ <br />MODIfICATION5 IN EX15TING 5HEAR WALL. PROVIDE NEW BLOCKING AND STRAPPING <br />PER DETAIL5. <br />3) BUILDING 15 NON-5PRINKLERED <br />8) MATCH, PATCH, PREP AND PAINT GWB WALL5 AND CEILINGS A5 REQ'D <br />FOE ENTIRE SPACE INCLUDING ALL NEW PARTITION WALL AND INfILL LOCATION5. <br />9) PROVIDE NEW FLOOR COVERINGS PER OWNER <br />1 O) THE PERMIT FOR ELECTRICAL /LIGHTING UPGRADE5 >=0R <br />TH15 PROJECT TO BE OBTAINED SEPARATELY BY SUBCONTRACTOR PRIOR <br />TO START OF WORK <br />4) RE-U5E EX15TING H-VAC SYSTEM AND DUCTING. MODIFY SUPPLY AND RETURN 1 1) PRIOR USE (OFFICE) ... PROP05ED U5E(OFFICE ...NO CHANGE <br />VENTING A5 REQ'D TO ACCOMMODATE THE (2) NEW BROKER OFFICE5 PER <br />FLOOR PLAN LAYOUT. (COORDINATE MODIFICATIONS WITH H-VAC CONSULTANT). <br />5) ALL EXTERIOR WINDOW GLAZING 5Y5TEM5 TO REMAIN A5 15. <br />G) INSPECT / REPAIR/ REPLACE ALL EX15TING 5PECIALIZED EGRE55 DOOR <br />HARDWARE TO MEET CURRENT CODE REQUIREMENTS. <br />7) EXISTING KE5TKOOM FIXTURE COUNT / LAYOUT TO REMAIN A5 15. (NO CHANGE) <br />JURISDICTION <br />PROJECT <br />DESCRIPTION <br />PROJECT NAME <br />PROJECT <br />ADDRESS . . . . . . . <br />TAX ACCOUNT NOs <br />PRESENT USE . . . <br />PROPOSED USE . . . . . . . <br />PROJECT TI <br />INTERIOR SQUARE <br />FOOTAGE <br />TOTAL INTERIOR . . . . . . . . <br />SQUARE FOOTAGE <br />VALL TO BE <br />:RTICAL MULLION <br />DOW GROUPING <br />CITY OF EVERETT PERMIT SERVICES <br />PROPOSED TENANT IMPROVEMENT <br />"INTERIOR ONLY" FOR A PROPERTY <br />MANAGEMENT OFFICE <br />WINDERMERE PROPERTY MANAGEMENT NW <br />7003 EVERGREEN WAY, SUITE A <br />EVERETT,WA 98203-5153 <br />#00392800601400 <br />BUSINESS- GROUP B <br />BUSINESS— GROUP B "NO CHANGE" <br />3088 SF (MINOR TENANT IMPROVEMENTS) <br />LOWER FLOOR 2544 SF <br />UPPER FLOOR 1044 SF <br />TOTAL 3088 SF <br />NONE SPRINKLERED <br />NO CHANGE <br />I MATCH TO TAGS IN DRAWINGS I <br />NEW ELECTRIC FIREPLACE INSERT: <br />PROVIDE 8" FURRING WALL TO ACCOMMODATE <br />NEW ELECTRIC FIREPLACE INSERT W/ TILE SURROUND. <br />MANUF: DIMPLEX SYNERGY 50" ELECTRIC FIREPLACE <br />INSERT MODEL BLF50-UL CERTIFICATION INFO <br />TO BE PROVIDED PRIOR AT INSPECTION <br />NEW APPLIED WOOD CEILING ACCENT: <br />INSTALL NEW WOOD CEILING ACCENT AS FOLLOWS: <br />-ATTACH 114" 4X8 HEM FIR PLYWD WITH GLUE AND <br />NO. 10 X 1- 1 /4" WD SCREWS TO EXISTING 2X <br />CEILING <br />STRUCTURE <br />- GLUE * BRAD NAIL (1 2) EQUALLY SPACED 2X2 <br />HELM FIR BOARDS TO BTM SIDE OF PLYWD <br />- GLUE * BRAD NAIL IX HEM FIR BOARDER TRIM <br />NEW RECEPTION DESK: <br />PROVIDE NEW RECEPTION DESK PER ENLARGED <br />PLAN DTL I /A3. 1. PROVIDE 30" HT MAX. COUNTERTOP <br />AND 30 WIDE MIN. ADA APPROACH <br />NEW CUSTOM METAL GUARDRAIL SYSTEM: <br />REMOVE EXISTING 2X4 WOOD FRAMED SOLID RAILING AS <br />REQ'D TO ACCOMMODATE NEW CUSTOM METAL GUARDRAIL <br />ATTACHED ON G" CURB. (SEE ELLV 5/A3. I* G/A3. 1) <br />GUARDRAIL TO BE A 30 HT. MIN. FROM FINISH FLOOR AND <br />FACE OF STAIR TREAD NOSING. PROVIDE CONTINUOUS HANDRAIL <br />FROM LOWER TO UPPER FLOOR. SYSTEM TO BE CONSTRUCTED PER <br />CURRENT WASHINGTON STATE HANDRAIL/GUARDRAIL CODES. <br />NEW OPENINGS IN EXISTING NON LOAD BEARING SHEAR WALL <br />PROVIDE NEW OPENINGS IN EXISTING SHEAR WALL TO ACCOMMODATE <br />ACCESS DOOR, SIDE-LITL AND UPPER RELITE. FOR (2) NEW OFFICE SPACES. <br />-SEE INTERIOR ELEVATION G/A3. 1 FOR ADDITIONAL INFO <br />-SEE ATTACHED STRUCTURAL DETAILS AND CALCULATIONS <br />NEW NON LOAD BEARING PARTITION WALL <br />PROVIDE NON LOAD BEARING PARTITION WALL TO CREATE (2) NEW <br />OFFICE SPACES. <br />-SEE I /A2. 1 FOR TYPICAL WALL SECTION <br />NEW SUSPENDED WOOD CEILING CLOUD <br />INSTALL NEW WOOD CEILING ACCENT AS FOLLOWS: <br />-SEE DETAILS .......... <br />ELECTRICAL/ LIGHTING UPGRADES AND MODIFICATIONS <br />- UPGRADE / MODIFY EXISTING LIGHTING SYSTEMS/lAYOUT <br />SEE SHT A2.3 FOR NEW LAYOUT AND BASIC FIXTURE SCHEDULE <br />- PROVIDE POWER TO PROPOSE NEW ELECTRIC FIREPLACE <br />- PROVIDE POWER AND DATA NE NEW AGENT DESK LOCATIONS <br />- PROVIDE POWER TO NEW TV LOCATION AT LOUNGE AREA <br />EXIT AND EMERGENCY LIGHTING <br />- ELECTRICAL CONTRACTOR TO INSPECT AND UPGRADE <br />EMERGENCY LIGHTING AND EXIST SIGNAGE AS NECESSARY <br />HATCH REPRESENTS NEW WALLS OR FURRING <br />HATCH REPRESENTS EX15TING WALL5 TO REMAIN <br />E <br />E <br />co <br />C) <br />0 <br />cu <br />CL <br />a) <br />2021-01 <br />A2mO <br />