I <br />I <br />Lo <br />Lo <br />I <br />18'-1 1/2" <br />REFLECTED CEILENG PLAN - LEVEL 01 <br />ScaIe' 1/8" = 1'-0" <br />0 <br />110 <br />17'-6" <br />6 ( 111-55/81, L5 '-5 7Y18" <br />0 4' 81 <br />9 <br />m <br />1. ALL NEW SWITCHES SHALL SEAT 48"A.F.F. UNLESS NOTED OTHERWISE. <br />2. ALL SWITCH PLATES, TOGGLES, AND DIMMERS SHALL MATCH BUILDING STANDARD. <br />3. CONTRACTOR TO PROVIDE AND INSTALL ALL FIRE ALARMS, DETECTION DEVICES & HORNISTROBES. <br />PROVIDE EMERGENCY LIGHTING THROUGHOUT TENANT SPACES. <br />4. ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS TO BE BIDDER -DESIGNED. <br />SUBCONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF DESIGN PLANS AND ENGINEERING <br />AND PERMITS. <br />5. PROVIDE TRAPEZE PIPE HANGERS FOR SUSPENDED PLUMBING PIPE. <br />6. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL, DUCTS, STRUCTURAL <br />ELEMENTS AND ALL OTHER RELATED ITEMS. INSTALL NEW PLUMBING, MECHANICAL, FANS, DUCTS, <br />CONDUITS, AND OTHER RELATED ITEMS SO AS NOT TO CONFLICT WITH ANY/ALL FIELD CONDITIONS <br />INCLUDING LUMINARIES. <br />7. ALL G.W.B. CEILINGS TO BE FINISHED TO LEVEL 4 PER FA-214. <br />S. LIGHT FIXTURES NOT LOCATED ON PLAN ARE TO BE CENTERED IN CEILING OF ROOM. <br />9. ALL LAMPS TO HAVE 3500K COLOR TEMPERATURE. <br />10. MULTIPLE SWITCHES ATONE LOCATION SHALL BE GANGED TOGETHER AND COVERED FINISHED <br />WITH ONE COVER PLATE U.N.O. <br />11. PROVIDE ADDITIONAL SWITCHING CONTROL REQUIRED BY NRECn <br />'12. LIMIT SWITCH CONTROL TO 80% LOAD OF A 20 AMP CIRCUIT. PER NRECIS13.2 <br />13. REPAIR ALL DAMAGED OR DISCOLORED GWB CEILING. <br />14. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, <br />DUCTS, SPRINKLERS, HN/AC, AND/OR EXISTING CONDUIT, PRIOR TO FRAMING FOR LIGHTS. ANY <br />DISCREPANCIES BETWEEN ARCHITECTS PROPOSED CEILING GRIDIPANEL LOCATIONS AND ACTUAL <br />FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. <br />CP-01 <br />(E) BEAM GWB WRAPPED SOFFIT TO REMAIN <br />...... .... ------ - - ---- - <br />CP-02 <br />. ....... ...... <br />(E) CEILING, LIGHT FIXTURES ANDS WITCHING TO REMAIN <br />CP-03 <br />RELOCATE SALVAGED LIGHT FIXTURES <br />CP-04 <br />NEW GW3 CEILING; REFER TO DETAILS ON SHEET A6.00 <br />5 <br />... .. ...... . .. ..... . ...... _-, ............ <br />NE ACT PERIMETER; REFER TO DETAILS ON SHEET A6.00 <br />P-06 <br />INFILL TO MATCH EXISTING CEILING <br />CP-07 <br />---------- <br />NEWACT CEILING-, REFER TO DETAILS ON SHEET A6.00 <br />CP-08 <br />RELOCATE SALVAGED "E"XHA_bS T,---F-A-,-N--C--P-,--,O-O"----, <br />LEGEND - CEILING PLAN <br />NO WORK THIS AREA w INTERNALLY ILLUMINATED EXIT SIGN <br />NEW GWB CEILING EXISTING GWB CEILING <br />NEW ACOUSTICAL CEILING <br />EXISTING ACOUSTICAL <br />TILE GRID <br />CEILING TILE GRID TO REMAIN <br />HEIGHT ABOVE FINISHED FLOOR _(2� EXHAUSTFAN <br />FREIHEIT <br />NEMMMIMM ARCH 1TIELTURE <br />001 <br />z <br />77 <br />z <br />ME <br />J <br />L ILI, <br />L�64 <br />Lu <br />) <br />Co., <br />> <br />"4- <br />LU <br />11477 <br />REGIST <br />ARCHF�, <br />, N <br />ISSUE LIST <br />PERMIT DOCLJPV'IENTS <br />PERMIT RESPONSE <br />LEVEL01 <br />REFLECTED <br />CEILING PLAN <br />fi'mull"IffigIrM 01 <br />if all Il <br />A t <br />'12/30/2020 <br />01/25/2021 <br />