Laserfiche WebLink
GENERAL NOTES <br />1. Contractor shall comply with the building codes as noted on drawings. <br />2. Contractor shall be responsible for providing all work and materials in accordance with all applicable city, county, and local building and <br />fire codes as required. <br />3. Contractor shall obtain and pay for all necessary permits other than the building permit. Additionally, pay for all other charges, fees or <br />costs associated with the work and charged by the municipality, utilities, or private companies <br />4. Contractor shall visit job site and verify all existing conditions and field dimensions prior to commencing work. Notify Architect if site <br />conditions and/or Building Department require any modifications to these drawings. <br />5. Contractor is responsible for maintaining a safe and clean construction site. <br />6. Contractor is responsible for providing temporary bracing as required until all permanent structural assemblies and connections are <br />secured. <br />7. Contractor shall establish an agreement with the Owner regarding allowable days and hours of work. Contractor shall not permit any <br />construction activity to commence, or allow employees to cause noise on site, outside of the agreed -upon work periods. <br />8. Contractor shall coordinate all equipment or systems to be salvaged and given to the Owner, with the Owner. The Owner shall direct the <br />Contractor as to the location of a storage area for salvaged items. The Contractor will be responsible for removing from the building and <br />the construction site all construction debris and/or items not retained by the owner's representative. <br />9. No storage or use of flammable or combustible liquids, torch cutting or welding operations, open flame work, grinding that produces <br />sparks, roofing operations, or use of flammable gas for temporary heating or drying shall be conducted on any construction site without <br />first having obtained a specific permit from the City of Bothell Fire Department for these hazardous activities. This includes demolition <br />work. Please call 425-806-6242 for Fire Department permit information and application. <br />10. Egress, separation, fire protection systems, and emergency access shall meet the requirements of 2015 International Fire Code (IFC) <br />chapter 33 during construction. Contractor materials and activities shall not block any exit, restrict emergency access, or impair fire <br />separation in any building while the building is occupied. This includes demolition work and also applies to neighboring areas, spaces, <br />and buildings. <br />11. omit <br />12. The existing fire safety (fire alarm/sprinkler) system(s) shall remain online in the building(s) during the remediation project. <br />13. Deferred submittals may be required for any modification of the existing fire sprinkler and/or fire alarm system(s). Any and all proposed <br />modifications must meet NFPA 13 and Bothell Municipal Code requirements. <br />14. If any of the fire safety (fire alarm/sprinkler) systems are offline during the course of the project, then a fire watch shall be posted while <br />the system(s) are offline. <br />EXISTING UIL I G CODE <br />Existing Building Code Compliance: The work shall be in accordance with <br />2018 International Existing Building Code (IEBC), Chapter 7 & 8. <br />ng <br />0 <br />U <br />100TH STREET SW <br />i <br />I <br />i <br />I <br />i <br />0 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />/ <br />1 <br />1 <br />1 <br />1 <br />1 <br />I <br />1 <br />1 <br />IN <br />I® <br />lZ <br />I� <br />`" <br />CD <br />_M <br />url�it »dtsil not <br />L,_._.®,_,_,_._._.------ ...... ...... ...... ...... ...... <br />663.48' N 89^ 24' 09" E Of <br />our <br />aMM���i"' ?rie <br />issuer Et of a permit bi011 Mlden <br />conewcoon documengi snd other <br />"N not prevO ttlat Fire Code <br />ofto fto requiringggo wf*ction <br />ate. <br />gy date: <br />15 <br />ra,w g a <br />�, <br />°'`,�`f .,s a �a 0gw T <br />' <br />rETI I T•� GA -0 <br />t .:f� <br />�. <br />„oa <br />SITE <br />311.82' S 89A 20,19" E <br />i <br />i <br />j w <br />Ell I �_ <br />� o <br />I� <br />IN <br />ICDIQ <br />IZ <br />_ <br />T <br />I <br />215.46' N 89A 20' 32" E WIT14441WES or z <br />AND.R <br />\TTACiKOOMMC ?1,T <br />;ant* 49161"it <br />�cel or sdt M r <br />Everett or th r <br />AicabftluIII111111111111l1 or laws. The <br />,uantAi based on <br />and other <br />,atOS"JASIS011111111M the Fire Code <br />)ffiestfSM0ftthe correction <br />f erronL <br />Date:__ <br />PROJECT DATA <br />PROJECT DESCRIPTION: Proposed repair of fire damaged unit K203. <br />Repairs include interior demo of fire damaged walls and cabinetry to be <br />replaced -in -kind, and replacement of damaged electrical and kitchen <br />appliances. Exterior repairs include replacement of existing windows with <br />new, replace -in -kind existing siding, roof fascia, attic vents, and roof gutters. <br />PROPERTY ADDRESS: 10115 Holly Drive <br />Everett, WA 98204 <br />PARCEL NUMBER: 28042400201100 <br />LEGAL DESCRIPTION: SEC 24 TWP 28 RGE 04ALL TH PTN W1/2 <br />NW1/4 NW1/4 LY S OF BEVERLY <br />PARK-EDMONDS RDA S CONVYD TO <br />SNO CO AF 771553 & 771554 <br />Q-S-T-R: NW-24-28-4 <br />LOT SIZE: 564,537.6 sq. ft. (12.96 Acres) <br />YEAR BUILT: 1989 <br />BUILDINGS: 18 (no change) <br />DWELLING UNITS: 352 (no change) <br />STORIES: 3 (no change) <br />N ZONING: R-3 Multiple Family Med. Density <br />(no change) <br />USE: Multiple Family Residential (MFR) <br />(no change) <br />JURISDICTION: City of Everett <br />CLASS: Wood Frame (no change) <br />CONSTRUCTION TYPE: Type V-A ( Non-Sprinklered) per 2018 IBC. <br />��_ (i L�� U <br />) R� <br />r <br />KILBURN <br />ARCHITECTS LLC <br />135 Lake Street South <br />Suite 250 <br />Kirkland, WA 98033 <br />Tel: 206.682.521 1 <br />Fax: 206.682.1403 <br />www.kilburnarchitects.com <br />7302 <br />\ REGISTERED <br />ARCHITECT <br />H. TODD KILBURN <br />STATE OF WASHINGTON <br />APR 14 2021 Permit#: B2103-M <br />Site Address: 10115 HOLLY DR #K203 <br />A-0.1 <br />Cover and Site Plan <br />A-1.0 <br />Floor Plan & Typ. Wall Section <br />A-2.0 <br />Elevations <br />A-3.1 <br />Details <br />A-3.2 <br />Details <br />A-3.3 <br />Details <br />Owner: STANDARD 1SP OLIN LLC <br />Tenant: OLIN FIELDS APTS-K303 <br />App. Date: 3/11/2021 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: REPAIR OF FIRE DAMAGED UNIT <br />R � LG(/ Date: ko)0;V1 <br />OfficeDet lab Site Set Fire/Planning Set <br />PROJECT TEAM <br />CLIENT / OWNER <br />ARCHITECT <br />STANDARD JSP OLIN LLC <br />KILBURN ARCHITECTS, LLC <br />655 Montgomery St, Ste 1700 <br />135 Lake Street South, Suite 250 <br />San Francisco, CA 94111 <br />Kirkland, WA 98033 <br />contact: H Todd Kilburn, AIA <br />todd@kilburnarchitects.com <br />�/ �® <br />9 � <br />t - 206.682.5211 <br />Lam/ -ids I <br />GENERAL CONTRACTOR <br />C <br />d4H6� <br />BLUE PINE CONSTRUCTION CORP. <br />4857 West 147th Street, Suite D <br />9Allbt >ll l <br />Hawthorne, CA 90250 (Main Office) <br />contact: Matt Harrison <br />matt@bluepinecc.com <br />- <br />t 424.800.3837 <br />Smoke Detectors Required: <br />• In each sleeping room, <br />. In each room giving access to a <br />sleeping room, <br />• Interconnected, <br />;f,QBattery backup, <br />"70)" Hardwired. <br />PLANNING 8COMMUNITY <br />BY f <br />DATE,71_�� 2-0- <br />0-,'� _ <br />/ <br />CITY OF EVERETT THESE DOCUMENTHAVF NOT BEEN <br />APPROVED FOR. T I l �S6UANCE OF <br />REVIEWED FOR PERMIT PUBLIC WORKS, ri'E'G•IANICAL, FIRE <br />SUPPRESSION, ELECTRICAL OR <br />PLUMBING PERMITS. <br />IL I <br />z� <br />SITE PLAN FOR REFERENCE ONLY <br />1 SCALE: 1" =100' - 0" <br />Additional Permits Are Required <br />For This Project To Include: <br />[2 Plumbing r� <br />en Mechanical Fire Alarm <br />Electrical <br />Orlin Fields Apt - <br />Unit K203 - <br />Fire Repair <br />10115 Holly Drive <br />Everett, WA 98204-8717 <br />Release Date <br />permit 3.4.2021 <br />AmOol <br />© 2021 KILBURN ARCHITECTS, LLC <br />