6133 LAKE CHAPLAIN RD 2021 Plans 2022-11-30
>
Address Records
>
LAKE CHAPLAIN RD
>
6133
>
Plans
>
6133 LAKE CHAPLAIN RD 2021 Plans 2022-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 8:21:49 AM
Creation date
10/19/2021 9:40:55 AM
Metadata
Fields
Template:
Address Document
Street Name
LAKE CHAPLAIN RD
Street Number
6133
Permit
B2103-038
Year
2021
Notes
Addition of steel stairs inside the operations bldg at WFP
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
=m <br />CONCRETE ANCHOR SCREWS <br />®� <br />A-241 Mal <br />SHOP & FIELDWELDING <br />SINGLE PASS FILLET WELDS:5 <br />PARTIAL & COMPLETE PENETRATION <br />ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. <br />SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY <br />THE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE <br />FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT <br />SPECIFICATIONS SHALLIMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. <br />SHOP DRAWINGS <br />SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER FOR REVIEW PRIOR TO FABRICATION: <br />1. STEEL GRATING 2. STRUCTURAL STEEL <br />3. STEEL GRATING TREADS 4. HAND RAILS <br />SHOP DRAWINGS SHALL BE REVIEWED, REVISED AS REQUIRED FOR FIELD CONDITIONS, AND DATE STAMPED <br />BY THE CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER. CONTRACTOR SHALL PROVIDE (3) SETS OF SHOP <br />DRAWINGS FOR ENGINEER'S REVIEW. ALLOW TWO WEEKS FOR SHOP DRAWING APPROVAL BY ENGINEER. <br />ENGINEER'S SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND <br />CONTRACT DOCUMENTS, MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE <br />CONTRACTOR FROM COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. THE CONTRACTOR <br />REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFORMING AND CORRELATING ALL <br />QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, <br />AND FOR PERFORMING THE WORK IN A SAFE MANNER. <br />ENGINEER'S SHOP DRAWING REVIEW OF STRUCTURAL COMPONENTS DESIGNED BY OTHERS IS FOR LOADS <br />IMPOSED ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE <br />CONFORMANCE AND ALL CONNECTIONS TO THE BASIC STRUCTURE. SHOP DRAWINGS SHALL INDICATE <br />MAGNITUDE AND DIRECTION OF THE LOADS IMPOSED ON THE BASIC STRUCTURE AND SHALL BE STAMPED <br />& SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS THE PROJECT. <br />FABRICATION SHALL BEGIN ONLY AFTER SHOP DRAWINGS BEARING THE STAMP AND SIGNATURE OF THE <br />PROJECT ARCHITECT, ENGINEER OF RECORD, AND CONTRACTOR HAVE BEEN RECEIVED. <br />STRUCTURAL STEEL <br />STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC <br />"SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", <br />LATEST EDITION. <br />SHAPES SHALL CONFORM TO ASTM A992, Fy e 60 KSI. <br />PLATES, ANGLES, AND RODS SHALL CONFORM TO ASTM A36, Fy m 36 KSI. <br />STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy e 46 KSI. <br />STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI. <br />BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N AND FIELD PAINTED WHITE. <br />BOLTS SHALL BE 3/4" 0 MINIMUM, UNO. ANCHOR BOLTS SHALL CONFORM TO ASTM A307 AND BE <br />HOT -DIPPED GALVANIZED OR STAINLESS STEEL WITH THE EXPOSED PORTIONS FIELD PAINTED WHITE. <br />CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS <br />OF AISC MANUAL OF STEEL CONSTRUCTION. <br />UNLESS NOTED OTHERWISE ON PLANS, ALL STEEL MEMBERS, SHAPES, PLATES, AND ACCESSORIES SHALL BE <br />EPDXY PAINTED WHITE. FINAL COLOR TO BE APPROVED BY OWNER. <br />WELDING <br />WELDING SHALL CONFORM TO AWS "STRUCTURAL WELDING CODE", LATEST EDITION. ALL WELDING SHALL BE <br />DONE WITH 70 KSI LOW HYDROGEN ELECTRODES. WHERE NOT CALLED OUT, MINIMUM FILLET WELD SIZE SHALL BE <br />PER TABLE 5.8 IN AWS D1.1, LATEST EDITION. <br />STEEL GRATING <br />PROVIDE GALVANIZED STEEL FLOOR GRATING BY GRATING PACIFIC OR APPROVED EQUAL. BAND ALL GRATING <br />EDGES. <br />TYPE OF GRATING: W-19-4 <br />SIZE OF BEARING BARS: 1 1/2" x 3/16" @ 1 3/16" OC <br />MAX SPAN: 4'-0" <br />MANUFACTURER/SUPPLIER TO PROVIDE CONNECTION OF GRATING TO STRUCTURAL STEEL WITH "G" CLIPS. SUBMIT <br />SHOP DRAWINGS FOR APPROVAL. <br />STEEL STAIR TREADS <br />PROVIDE GALVANIZED STEEL STAIR TREADS BY GRATING PACIFIC OR APPROVED EQUAL. <br />TYPE OF GRATING: W-19-4 <br />SIZE OF BEARING BARS: 1 3/4" x 3/16" @ 1 3/16" OC <br />NOMINAL TREAD WIDTH: 9 3/4" <br />MANUFACTURER/SUPPLIER TO PROVIDE CONNECTION OF GRATING TO STRUCTURAL STEEL WITH "G" CLIPS. SUBMIT <br />SHOP DRAWINGS FOR APPROVAL. <br />PROVIDE DIAMOND PLATED NOSING WELDED TO GRATING <br />STAIR TREADS SHALL BE ANCHORED TO STRINGERS W/ A MINIMUM OF (4) 1 /2" 0 WHS. <br />EXISTING BUILDING <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING <br />DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE <br />REDESIGN. <br />GENERAL <br />STRUCTURAL DRAWINGS SHALL BE USED FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY <br />ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL <br />BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. <br />CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND <br />LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY <br />UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. <br />CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP <br />DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. <br />DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE <br />STRUCTURAL ENGINEER. <br />3200 Cedar Street <br />Everett, WA 93201 <br />425.257.8800 everettwa.gov <br />LEGEND <br />DEFINITION <br />SYMBOL <br />DEFINITION <br />SYMBOL <br />DIRECTION OF <br />FRAMING <br />NATIVE SOIL <br />I(1=1III�-III. -1II <br />EXTENT <br />FRAMINGG <br />GRANULAR FILL <br />COLUMNS <br />STRUCTURAL STEEL�Tr� <br />�rrnr� <br />COLUMN BEARING <br />ON BEAM <br />RATED SHEATHING <br />BEAM CONTINUOUS <br />OVER SUPPORT <br />� <br />SHEAR WALL <br />(SEE SCHEDULE) <br />SWX <br />CONCRETE WALL <br />COLUMN MARK <br />(SEE SCHEDULE) <br />1 <br />BEARING STUD <br />WALL <br />FOOTING MARK <br />(SEE SCHEDULE) <br />FX <br />(�----�--r- <br />NON -BEARING <br />STUD WALL <br />l' <br />> - - <br />HOEDOWN MARK <br />(SEE SCHEDULE) <br />BEARING STUD <br />SHEAR WALL <br />HANGER MARK <br />(SEE SCHEDULE) <br />X <br />-J� <br />NON -BEARING <br />STUD SHEAR WALL <br />FLAG NOTE <br />(SEE PLAN NOTES) <br />X <br />Z Z <br />CMU WALL <br />STEEL MOMENT <br />FRAME CONN. <br />ABBREVIATIONS <br />(A) <br />ABOVE <br />GLB <br />GLUE -LAMINATED BEAM <br />AB <br />ANCHOR BOLT <br />HORIZ <br />HORIZONTAL <br />ALT <br />ALTERNATE <br />KP <br />KING POST <br />ARCH <br />ARCHITECT <br />KSI <br />KIPS PER SQUARE INCH <br />(B) <br />BELOW <br />L <br />ANGLE <br />BD <br />BAR DIAMETER <br />MECH <br />MECHANICAL <br />BLKG <br />BLOCKING <br />MF <br />MOMENT FRAME <br />BM <br />BEAM <br />MTL <br />METAL <br />BOT <br />BOTTOM <br />NS <br />NEAR SIDE <br />BRNG <br />BEARING <br />OC <br />ON CENTER <br />BTWN <br />BETWEEN <br />OPP <br />OPPOSITE <br />CJP <br />COMPLETE JOINT PENETRATION <br />PL <br />PLATE <br />CLR <br />CLEAR <br />PLCS <br />PLACES <br />CMU <br />CONCRETE MASONRY UNIT <br />PSI <br />POUNDS PER SQUARE INCH <br />COL <br />COLUMN <br />PSF <br />POUNDS PER SQUARE FOOT <br />CONC <br />CONCRETE <br />P/T <br />POSTTENSIONED <br />CONN <br />CONNECTION <br />PT <br />PRESSURE TREATED <br />CONT <br />CONTINUOUS <br />REINF <br />REINFORCING <br />COORD <br />COORDINATE <br />REQ'D <br />REQUIRED <br />DBL <br />DOUBLE <br />SCHED <br />SCHEDULE <br />DET <br />DETAIL <br />SIM <br />SIMILAR <br />DIA <br />DIAMETER <br />SOG <br />SLAB ON GRADE <br />DIM <br />DIMENSION <br />STD <br />STANDARD <br />DIR <br />DIRECTION <br />STIFF <br />STIFFENER <br />EA <br />EACH <br />STL <br />STEEL <br />ELEV <br />ELEVATION <br />SYMM <br />SYMMETRICAL <br />ES <br />EACH SIDE <br />SW <br />SHEARWALL <br />EX <br />EXISTING <br />TOC <br />TOP OF CONCRETE <br />EXP <br />EXPANSION <br />TOS <br />TOP OF STEEL <br />FLR <br />FLOOR <br />TOW <br />TOP OF WALL <br />FDN <br />FOUNDATION <br />TYP <br />TYPICAL <br />FTG <br />FOOTING <br />UNO <br />UNLESS NOTED OTHERWISE <br />FS <br />FAR SIDE <br />VERT <br />VERTICAL <br />GC <br />GENERAL CONTRACTOR <br />WE <br />WIDE FLANGE <br />