<br />FOR SI: I SQUARE FOOT 6._0_929M',__lCUBIC FOOT PER MINUTE = f_
<br />TABLEk
<br />WHOLE-HOUSEINTERMITTENT R.
<br />METHOD ,1 1, IRC M1507.3.4 M HOUR VENTILATIONUSING EXHAUST FANS.
<br />M1507.3. WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING MOLE HOUSE
<br />VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE
<br />M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI
<br />916 OR A.MCA 210.
<br />M1507.3;4,2 FAN NOISE. MOLE HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR
<br />GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE.
<br />MANUFACTURER'S NOISE RATINGS SHALL, BE DETERMINED AS PER HVI 915 MARCH 20MP.
<br />REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLYISOLATED FROM THE STRUCTURAL ELEMENTS
<br />OF THE BUILDING AND FROM ATTACHED :DUCT WORK USING INSULATED FLEXIBLE DUCT M OTHER
<br />APPROVED MATERIAL.
<br />M1507.3.4.3 FAN CONTROL S. TIME HOUSE VENTILATION FALL SHALE MEET THE
<br />REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1.
<br />M1507.3.4.4 VENTILATION OPENINGS. EACH HABITABLE SPACE SHAD OF PROVIDED WITH OUTDOOR AIR
<br />INLETS OR OPERABLE WINDOWS WITH M OPENABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET
<br />FREE AREA OF OPENING FOR EACH 10 CM OF OUTDOOR AIR REQUIRED BY TABLE M1 7.333(1). WHERE
<br />OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS. PROVISIONS SHALL BE
<br />MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS,
<br />INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHAD, BE UNDERCUT TO A MINIMUM
<br />OF 1 J2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING.
<br />INDIVIDUAL RON OUTDOOR AIR INLETS SHALL;
<br />1. HAVE CONTROLLABLE AND SECUREOPENINGS;
<br />2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES
<br />OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED;
<br />3, ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 GEM AT 10 PASCALS ARE DEEMED
<br />EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA,
<br />VENTILATION OPENING SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR
<br />OTHER MATERIAL, OPENINGS STALL BE CONTROLLABLE, R AN A BE C , SECU ABLE D SHALL DESIGNED TO
<br />NOT COMPROMISE THE THERMAL PERTIES OF THE BUILDING ENVELOPE. VENTILATION OPENINGS
<br />SHALT BE LOCATED SO AS NOT TO TAKE AIR FROM THE FLOWING AREAS.
<br />1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3
<br />FEET ABOVE THE OUTDOOR AIR INLET.
<br />2. MERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS.
<br />3. A HAZARDOUS OR UNSANITARY LOCAT110N.
<br />4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN.
<br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE
<br />VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET.
<br />6. ATTIC, CRAM SPACES, OR GARAGES.
<br />7. ASPHALT ROOFS UNLESS IT IS SHOWN THAT NO OTHER LOCATION IS PERMISSIBLE. IN SUCH
<br />CASES THE INLET OPENING SHALL BE LOCATED A MINIMUM OF 2 FEET FROM THE NEAREST
<br />SURFACE OF THE ASPHALT ROOFING, MEASURED FROM THE INTAKE OPENING.
<br />METHOD 2, M1507.3.5.1 INTEGRATED MOLE HOUSE VENTILATION SYSTEMS. INTEGRATED
<br />WHOLE- SE VENTILATION SYSTEMS MALL PROVIDE OUTDOOR AIR AT THE RATE CALCULATED
<br />USING SECION M1507.3.3. INTEGRATED FORCED -AIR VENTILATION SYSTEMS MALL DISTRIBUTE
<br />OUTDOOR AIR TO EACH HABITABLE SPACE THROUGH THE FORCED -AIR SYSTEM DUCTS. INTEGRATED
<br />FOR -AIR VENTILATION SYSTEMS SHALL HAVE AN OUTDOOR AIR INLET DUCT CONNECTING A
<br />TERMINAL, ELEMENT ON THE OUTSIDE OF THE BUILDING TO THE RETURN AIR PLENUM OF THE
<br />FORCED -AIR SYSTEM, AT A POINT WITHIN 4 FEET UPSTREAM OF THE AIR HANDLER. THE OUTDOOR
<br />AIR INLET DUCT CONNECTION TO THE RETURN AIR STREAM SHALL BE LOCATED UPSTREAM OF THE
<br />FORCED -AIR SYSTEM BLOWER AND SHALL NOT BE CONNECTED DIRECTLY INTO A FURNACE CABINET
<br />TO PREVENT THERMAL { TO THE HEAT EXCHANGER. THE SYSTEM WILL BE EQUIPPED WIN A
<br />MOTORIZE DAMPER CONNECTED TO THE AUTOMATIC VENTILATION CONTROL AS SPECIFIED IN
<br />SECTION M1507.3.2. THE REQUIRED FLOW RATE SHALL BE VERIFIED BY FIELD TESTING WITH A FLOW
<br />HOOD OR A FLOW MEASURING STATION.
<br />M1507.3.5.2 VENTILATION DUCT INSULATION. ALE SUPPLY DUCTS IN THE TINED SPACE
<br />SHALL BE INSULATED TO A MINIMUM OF R-4.
<br />M17.3.5,3 OUTDOOR AIR INLETS. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM
<br />ENTRY BY LEAVES OR OTHER MATERIAL OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO
<br />TAKE AIR FROM THE FOLLOWING AREAS-
<br />1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3
<br />FEET ABOVE THE OUTDOOR AIR INLET
<br />2. MERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS.
<br />3. A HAZARDOUS OR UNSANITARY LOCATION.
<br />4. A ROOM OR SPACE HAVING MY FUEL -BURNING APPLIANCES THEREIN.
<br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE
<br />VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET.
<br />6. ATTIC, CRAWL SPACES, OR GARAGES,
<br />METHOD #3, M1507.3.6, MOLE HOUSE VENTILATION USING A SUPPLY FAN. SUPPLY FAN
<br />VENTILATION SYSTEMS SHALL DISTRIBUTE OUTDOOR AIR TO EACH HABITABLE SPACE T"ROUCH THE
<br />FORCED -AIR SYSTEM DUCTS OR THROUGH DEDICATED DUCTS TO EACH HABITABLE SPACE. SUPPLY
<br />FANS SHALL HAVE THE CAPACITY TO PROVIDE THE AMOUNT OF OUTDOOR AIR SPECIFIED IN TABLE
<br />M1507.3.' 1 AT 0.40 INCITES WATER GAUGE AS PER HVI 916. THE OUTDOOR AIR MUST BE
<br />FILTERED ORE IT IS DELIVERED TO HABITABLE SPACES. THE FILTER MAY BE LOCATED AT THE
<br />INTAKE DEVICE, IN DINE WITH THE FAN, OR, IN THE CASE OF A CONNECTION TO THE RETURN
<br />PLENUM OF THE AIR HANDLER, USING THE FURNACE FILTER. AN OUTDOOR AIR INLET SHALL BE
<br />CONNECTED TO EITHER THE SUPPLY OR RETURN AIR STREAM.
<br />M1507.3,6.2 DUCTS. AN OUTDOOR AIR INLET DUCT CONNECTION TO THE SUPPLY AIR STREAK SHALL
<br />BE LOCATED DOWNSTREAM OF THE FORCEO-AIR SYSTEM BLOWER. IF CONNECTED TO THE RETURN AIR
<br />STREAM IT SHALL BE LOCATED AT LEAST 4 FEET UPSTREAM OF THE FORCED -AIR 'SYSTEM BLOWER
<br />AND ITS FILTER, NEITHER MALL BE CONNECTED DIRECTLY INTO A FURNACE CABINET. THE DUCT
<br />SHALL BE SIZED IN ACCORDANCE WITH TABLE M1507.3.6.2. THE TERMINAL ELEMENT ON THE ODUTSDE
<br />OF THE BUILDING MALL BE SIZED 2 INCHES DIA. LARGER THAN THE OUTDOOR AIR INLET DUCT.
<br />TABLE M1507.3.6.2
<br />PRESCRIPTIVE SUPPLY FAN DUCT SIZING
<br />SUPPLY FAN TESTED CF-M AT 0,40" WG
<br />SPECIFIED
<br />VOLUME FROM
<br />TABLE
<br />M1507.3.3(1)
<br />METHOD ,1 1, IRC M1507.3.4 M HOUR VENTILATIONUSING EXHAUST FANS.
<br />M1507.3. WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING MOLE HOUSE
<br />VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE
<br />M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI
<br />916 OR A.MCA 210.
<br />M1507.3;4,2 FAN NOISE. MOLE HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR
<br />GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE.
<br />MANUFACTURER'S NOISE RATINGS SHALL, BE DETERMINED AS PER HVI 915 MARCH 20MP.
<br />REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLYISOLATED FROM THE STRUCTURAL ELEMENTS
<br />OF THE BUILDING AND FROM ATTACHED :DUCT WORK USING INSULATED FLEXIBLE DUCT M OTHER
<br />APPROVED MATERIAL.
<br />M1507.3.4.3 FAN CONTROL S. TIME HOUSE VENTILATION FALL SHALE MEET THE
<br />REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1.
<br />M1507.3.4.4 VENTILATION OPENINGS. EACH HABITABLE SPACE SHAD OF PROVIDED WITH OUTDOOR AIR
<br />INLETS OR OPERABLE WINDOWS WITH M OPENABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET
<br />FREE AREA OF OPENING FOR EACH 10 CM OF OUTDOOR AIR REQUIRED BY TABLE M1 7.333(1). WHERE
<br />OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS. PROVISIONS SHALL BE
<br />MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS,
<br />INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHAD, BE UNDERCUT TO A MINIMUM
<br />OF 1 J2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING.
<br />INDIVIDUAL RON OUTDOOR AIR INLETS SHALL;
<br />1. HAVE CONTROLLABLE AND SECUREOPENINGS;
<br />2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES
<br />OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED;
<br />3, ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 GEM AT 10 PASCALS ARE DEEMED
<br />EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA,
<br />VENTILATION OPENING SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR
<br />OTHER MATERIAL, OPENINGS STALL BE CONTROLLABLE, R AN A BE C , SECU ABLE D SHALL DESIGNED TO
<br />NOT COMPROMISE THE THERMAL PERTIES OF THE BUILDING ENVELOPE. VENTILATION OPENINGS
<br />SHALT BE LOCATED SO AS NOT TO TAKE AIR FROM THE FLOWING AREAS.
<br />1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3
<br />FEET ABOVE THE OUTDOOR AIR INLET.
<br />2. MERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS.
<br />3. A HAZARDOUS OR UNSANITARY LOCAT110N.
<br />4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN.
<br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE
<br />VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET.
<br />6. ATTIC, CRAM SPACES, OR GARAGES.
<br />7. ASPHALT ROOFS UNLESS IT IS SHOWN THAT NO OTHER LOCATION IS PERMISSIBLE. IN SUCH
<br />CASES THE INLET OPENING SHALL BE LOCATED A MINIMUM OF 2 FEET FROM THE NEAREST
<br />SURFACE OF THE ASPHALT ROOFING, MEASURED FROM THE INTAKE OPENING.
<br />METHOD 2, M1507.3.5.1 INTEGRATED MOLE HOUSE VENTILATION SYSTEMS. INTEGRATED
<br />WHOLE- SE VENTILATION SYSTEMS MALL PROVIDE OUTDOOR AIR AT THE RATE CALCULATED
<br />USING SECION M1507.3.3. INTEGRATED FORCED -AIR VENTILATION SYSTEMS MALL DISTRIBUTE
<br />OUTDOOR AIR TO EACH HABITABLE SPACE THROUGH THE FORCED -AIR SYSTEM DUCTS. INTEGRATED
<br />FOR -AIR VENTILATION SYSTEMS SHALL HAVE AN OUTDOOR AIR INLET DUCT CONNECTING A
<br />TERMINAL, ELEMENT ON THE OUTSIDE OF THE BUILDING TO THE RETURN AIR PLENUM OF THE
<br />FORCED -AIR SYSTEM, AT A POINT WITHIN 4 FEET UPSTREAM OF THE AIR HANDLER. THE OUTDOOR
<br />AIR INLET DUCT CONNECTION TO THE RETURN AIR STREAM SHALL BE LOCATED UPSTREAM OF THE
<br />FORCED -AIR SYSTEM BLOWER AND SHALL NOT BE CONNECTED DIRECTLY INTO A FURNACE CABINET
<br />TO PREVENT THERMAL { TO THE HEAT EXCHANGER. THE SYSTEM WILL BE EQUIPPED WIN A
<br />MOTORIZE DAMPER CONNECTED TO THE AUTOMATIC VENTILATION CONTROL AS SPECIFIED IN
<br />SECTION M1507.3.2. THE REQUIRED FLOW RATE SHALL BE VERIFIED BY FIELD TESTING WITH A FLOW
<br />HOOD OR A FLOW MEASURING STATION.
<br />M1507.3.5.2 VENTILATION DUCT INSULATION. ALE SUPPLY DUCTS IN THE TINED SPACE
<br />SHALL BE INSULATED TO A MINIMUM OF R-4.
<br />M17.3.5,3 OUTDOOR AIR INLETS. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM
<br />ENTRY BY LEAVES OR OTHER MATERIAL OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO
<br />TAKE AIR FROM THE FOLLOWING AREAS-
<br />1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3
<br />FEET ABOVE THE OUTDOOR AIR INLET
<br />2. MERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS.
<br />3. A HAZARDOUS OR UNSANITARY LOCATION.
<br />4. A ROOM OR SPACE HAVING MY FUEL -BURNING APPLIANCES THEREIN.
<br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE
<br />VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET.
<br />6. ATTIC, CRAWL SPACES, OR GARAGES,
<br />METHOD #3, M1507.3.6, MOLE HOUSE VENTILATION USING A SUPPLY FAN. SUPPLY FAN
<br />VENTILATION SYSTEMS SHALL DISTRIBUTE OUTDOOR AIR TO EACH HABITABLE SPACE T"ROUCH THE
<br />FORCED -AIR SYSTEM DUCTS OR THROUGH DEDICATED DUCTS TO EACH HABITABLE SPACE. SUPPLY
<br />FANS SHALL HAVE THE CAPACITY TO PROVIDE THE AMOUNT OF OUTDOOR AIR SPECIFIED IN TABLE
<br />M1507.3.' 1 AT 0.40 INCITES WATER GAUGE AS PER HVI 916. THE OUTDOOR AIR MUST BE
<br />FILTERED ORE IT IS DELIVERED TO HABITABLE SPACES. THE FILTER MAY BE LOCATED AT THE
<br />INTAKE DEVICE, IN DINE WITH THE FAN, OR, IN THE CASE OF A CONNECTION TO THE RETURN
<br />PLENUM OF THE AIR HANDLER, USING THE FURNACE FILTER. AN OUTDOOR AIR INLET SHALL BE
<br />CONNECTED TO EITHER THE SUPPLY OR RETURN AIR STREAM.
<br />M1507.3,6.2 DUCTS. AN OUTDOOR AIR INLET DUCT CONNECTION TO THE SUPPLY AIR STREAK SHALL
<br />BE LOCATED DOWNSTREAM OF THE FORCEO-AIR SYSTEM BLOWER. IF CONNECTED TO THE RETURN AIR
<br />STREAM IT SHALL BE LOCATED AT LEAST 4 FEET UPSTREAM OF THE FORCED -AIR 'SYSTEM BLOWER
<br />AND ITS FILTER, NEITHER MALL BE CONNECTED DIRECTLY INTO A FURNACE CABINET. THE DUCT
<br />SHALL BE SIZED IN ACCORDANCE WITH TABLE M1507.3.6.2. THE TERMINAL ELEMENT ON THE ODUTSDE
<br />OF THE BUILDING MALL BE SIZED 2 INCHES DIA. LARGER THAN THE OUTDOOR AIR INLET DUCT.
<br />TABLE M1507.3.6.2
<br />PRESCRIPTIVE SUPPLY FAN DUCT SIZING
<br />SUPPLY FAN TESTED CF-M AT 0,40" WG
<br />SPECIFIED
<br />VOLUME FROM
<br />TABLE
<br />M1507.3.3(1)
<br />MINIMUM
<br />SMOOTH DUCT=
<br />DIAMETER
<br />MINIMUM
<br />FLEXIBLE DUCT
<br />DIAMETER
<br />50-90cfm
<br />4 [NOT _
<br />5 INCH
<br />90-150cfm
<br />5 INCH
<br />6 INCH
<br />150--120cfm
<br />6INCH
<br />71N0H
<br />250-400cfm
<br />7 INCH
<br />6 INC 1
<br />M1507.3,6.3 DAMPERS. THE SYSTEM SHAsi BE EQUIPPED WITH A BACK -DRAFT DAMPER AND ONE
<br />OF THE FOIa OWING:
<br />1. A CALIBRATED MANUAL VOLUME DAMPER INSTALLED AND SET TO MEET THE MEASURE FLOW
<br />RATES SPECIFIED IN TABLE M1507.3.3(1) BY FIEF TESTING WIN A PRESSURE GAUGE ANDIOR
<br />FOLLOWING MANUFACTURER'S INSTALLATION INSTRUCTIONS; OR
<br />2. A MANUAL VOLUME DAMPER INSTALLED AND SET TO MEET THE MEASURED FLOW RATES
<br />SPECIFIED IN TABLE M1507.3.3(1) BY FIEW TESTING WITH A FLOW HOOD OR A FLOW MEASURING
<br />STATION; OR
<br />3. AN AUTOMATIC FLOW -REGULATING DEVICE° Si`UT TO THE SPECIFIED FLOW RATES IN TABLE
<br />M1507.3.3(1) MICH PROVIDES CONSTANT FLOW OVER A PRESSURE RANGE OF 0.20 TO 0.60
<br />INCHES WATER GAUGE.
<br />M1507.3.6,4 VENTILATION DUCT INSULATION. ALL SUPPLY DUCTS IN THE CONDITIONED SPACE
<br />SHALL BE INSULATED TO A MINIMUM OF R-4.
<br />M1507.3.6.5 OUTDOOR AIR INLETS. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM
<br />ENTRY BY LEAVES OR OTHER MATERIAL., OUTDOOR AIR INLETS SHALE BE LOCATED SO AS NOT TO
<br />TAKE AIR. FROM THE FOI 0Q NC AREAS:
<br />1, CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3
<br />FEET ABOVE THE OUTDOOR AIR INLET.
<br />2. MERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLEF VAPORS.
<br />3. A HAZARDOUS OR UNSANITARY LOCATION.
<br />4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN.
<br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE
<br />VENT OPENING IS AT II FAST 3 FEET ABOVE THE AIR INLET,
<br />. ATTIC, CRAWL SPACES, OR GARAGES.
<br />SOLID FUEL NAMING APPLIANCES (INUDING WOOD STOVES, ROOM HEATERS, FACTORY MILT
<br />FIREPLACES, FIREPLACE" INSERTS, AND MASONRY HEATERS) SHALL COMPLY WITH THE PROVISIONS
<br />OF IMC, CHAPTERS 3 AND 9, AND IRC CHAPTER 10.
<br />SOLID FUEL BURNING APPLIANCES SHAD BE PROVIDED BOTH TIGHT FITTING METAL OR CERAMIC
<br />GLASS DOORS AND ME OF THE FOLLOWING;
<br />1. A SOURCE FROM OUTSIDE THE STRUCTURE OF PRIMARY COMBUSTION AIR, CONNECTED TO THE
<br />APPLIANCE AS PER MANUFACTURER'S SPECIFICATION. THE AIR INLET SHALL ORIGINATE AT A POINT
<br />BELOW THE FIRE BOY, THE DUCT SHALL BE 4 INCHES OR GREATER IN DIAMETER, NOT EXCEED 20
<br />FEET IN LENGTH, AND BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS;
<br />2. THE APPLIANCE AND MANUFACTURER'S RECOMMENDED COMBUSTION AIR SUPPLY, AS AN
<br />INSTALLED UNIT, SHALL BE CERTIFIED BY AN INDEPENDENT TESTING LABORATORY TO HAVE PASSED
<br />TEST NO, II -NEGATIVE PRESSURE TEST, SECTION 12.3, OF ULC 627-M1964 "SPACE HEATERS
<br />FOR USE 'NTH SOLID FUELS."
<br />FIREPLACES SHAD BE PROVIDED WITH READILY ACCESSIBLE MANUAL OR APPROVED AUTOMATIC
<br />TIGHT nTONG FLUE DAMPERS, EXCEPT FIREPLACES WITH GAS LOGS MUST COMPLY WITH IMC 901
<br />OR LIQUEFIED PETROLEUM GAS INSTALLATIONS SHALL BE PER NFPA 58 AND 54. A 6 SQ. IN.
<br />OUTSIDE SOURCE FOR COMBUSTION AIR SHALL BE PROVIDED WHIT AN OUTSIDE AIR DUCT DAMPER
<br />(EXCEPTION: WA CERTIFIED FIREPLACES MALL.. BE INSTALLED WITH THE COMBUSTION AIR SYSTEM
<br />NECESSARY FOR TH R SAFE AND EFFICIENT COMBUSTION AS SPECIFIED BY THE MANUFACTURER).
<br />SITE BUILT FIREPLACES SHALL HAVE TINT FITTING GLASS OR METAL DOORS, OR A FLUE DRAFT
<br />INDUCTION FAN OR AS APPROVED FOR MINIMIZING BACK -DRAFTING. FACTORY BUILT FIREPLACES
<br />SHALL USE DOORS LISTED FOR THE INSTALLED APPLIANCE.
<br />CITY OF EVERETT
<br />FOR PERMIT
<br />COPYRIGHT* 2-019 OF -SIGN LINES, INC., ALL RIGHTS RESERVED. THE USE OF THIS SHEET IS
<br />EXCLUSIVELY FOR THE CLIENTS OF DESIGN [LINES, INC. AND ONLY FOR THE PARTICULAR PROJECT
<br />FOR WHICH THE PRINTS WERE ISSUED. USE OR REUSE OF THIS SHEET FOR ANY OTHER PROJECT IS
<br />STRICTLY FORBIDDEN AND SUBJECT TO PENALTY OF LAW.
<br />I
<br />tj 5
<br />209
<br />R
<br />-
<br />■
<br />MR
<br />M
<br />Ly
<br />® L
<br />0 of
<br />®
<br />c�
<br />00
<br />U) z
<br />of En
<br />sew
<br />Ld
<br />s
<br />ry
<br />00
<br />cq
<br />00
<br />�I
<br />Go
<br />
|