Laserfiche WebLink
Permit#: B2105-023 <br />Site Address: 616 PECKS DR <br />Owner: EVERETT SCHOOL DIST 2 <br />Tenant: MADISON ELEMENTARY SCHOOL <br />Ann F1atP- SMt7-M-)I <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: NEW 887SF PORTABLE P1, LANDI <br />RAMP TO BE INSTALLED <br />1 L 4 5 Reviewed B / Date( <br />Office Set Job Site Set Fire/Plan <br />THESE DOCUMENTS HAVE NOT BEEN <br />APpROVEC) FOR .THEISSUANCE OF <br />�fEC�lAI�ICAp.. SIRE <br />PUBLIC WORKS <br />SUPPRESSION, 5LECTRICAL OR <br />VLUM18ING PERMITS. <br />DYKEMAN <br />Additional Permits Are Required ARCHITECTURE + DESIGN <br />Madison ES 2021 P rtables For This Project To Include: <br />❑ Plumbing ❑ Sprinkler www.dykeman.net 1716 - Marine - Drive D <br />Mechanical � Fire AlarrnFloorEverett,98201 <br />o <br />Electrical <br />VICINITY MAP <br />SCALE: 1" = 2000' - 0" <br />L <br />EVERETT S.D. <br />3900 BROADWAY <br />EVERETT WA 98201 <br />Contact: JENNIFER COLLINS <br />Phone: (425) 385-4195 <br />Email: jcollins@everettsd.org <br />ARCHITECT <br />DYKEMAN, INC. <br />1716 WEST MARINE VIEW DR <br />EVERETT WA 98201 <br />Contact: ZACHARY HAM <br />Phone: (425) 259-3161 <br />Email: zachh@dykeman.net <br />ELECTRICAL ENGINEER <br />HARGIS ENGINEERS <br />1201 3RD AVE STE 600 <br />SEATTLE WA 98101 <br />Contact: MARK HUMISTON <br />Phone: (206) 448-3376 <br />Email: mark.humiston@hargis.biz <br />STRUCTURAL ENGINEER <br />BRIGGS ENGINEERING INC <br />PO BOX 140537 <br />GARDEN CITY ID 83714 <br />Contact: DEAN BRIGGS <br />Phone: (208) 871-0200 <br />Email: briggsengineering@msn.com <br />RAMPS AND LANDINGS <br />WELCOME RAMP SYSTEMS <br />2361 SOUTH 2O0TH ST <br />SEATTLE WA 98198 <br />Contact: TERRI GORDON <br />Phone: (866) 935-9255 <br />Email: sales@welcomerampsystems.com <br />PROJECT INFORMATION <br />LEGAL DESCRIPTION <br />SEC 06 TWP 28 RGE 05N 470FT OF E 463AFT OF GOUT LOT 7 TGW W 115FT <br />OF LOTS 76,77 & 78 PLAT OF BEVERLY HILLS DIVE 3 & TGW LOTS 10,25 & 26 <br />PLAT OF PECKS BAY VIEW TRACTS LESS THAT PTN LOT 10 TO CITY OFEVT <br />PER AF NO. 2369176 VOL 831 PG 138 DAF BEG AT NE COR LOT 10 TH ALG E <br />LN LOT10 FOR 6FT TH N89*32 55W 214.93FT TAP OFTANG TO A CRV TO L TH <br />ON CRV TO L HAVGA RAID OF 18.51FT & A C/A OF 92*29 25 ON A ARC DIST OF <br />29.86FT TAP OF TANG WITH A LN WH IS PLT & 8FT DIST FR W LN SD LOT10 TH <br />WPLTNLNSDLOT 8FTTOWLNSDSDLOT THNONSDWLNTONWCOR <br />THOFTH E ALG N LN TO POB MADISON SCHOOL-EV SCH DIST NO. 2 <br />TAX ACCOUNT NUMBER(S) <br />28050600302000 <br />DEFERRED SUBMITTALS <br />1. FIRE ALARM <br />GOVERNING CODES <br />1. WAC 51-50 INTERNATIONAL BUILDING CODE, 2018 EDITION <br />2. WAC 51-52 INTERNATIONAL MECHANICAL CODE, 2018 EDITION <br />3, WAC 51-54 INTERNATIONAL FIRE CODE, 2018 EDITION <br />4. WAC 51-57 UNIFORM PLUMBING CODE, 2018 EDITION <br />5. WAC 51-11 WASHINGTON STATE ENERGY CODE, 2018 EDITION <br />6. 2018 EDITION NFPA STANDARD 72, 13, 13-D, 13-R 2002 <br />7. ICC/ANSI A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br />DRAWING INDEX <br />GENERAL <br />G01 TITLE SHEET, PROJECT INFORMATION <br />ARCHITECTURAL <br />AS1.0 OVERALL SITE PLAN <br />AS1.1 PARTIAL SITE PLAN - PORTABLES <br />AS1.1 PARTIAL SITE PLAN - BREEZEWAY ACCESS <br />ELECTRICAL <br />E-001 ELECTRICAL LEGEND & DRAWING INDEX <br />E-002 ELECTRICAL GENERAL NOTES & ABBREVIATIONS <br />ED-101 ELECTRICAL DEMOLITION SITE PLAN <br />E-101 ELECTRICAL SITE PLAN <br />E-102 LOW -VOLTAGE SITE PLAN <br />E-301 ELECTRICAL & LOW -VOLTAGE FLOOR PLAN <br />E-701 PORTABLE DETAILS <br />E-702 TELECOM DETAILS <br />E-901 ELECTRICAL PANEL SCHEDULE & ONE -LINE DIAGRAM <br />WELCOME RAMPS LANDINGS AND STAIRS <br />1 OF 1 STANDARD PLANS AND DETAILS <br />28X32 PORTABLE PLANS <br />A-1 FLOOR PLAN, DOOR AND WINDOW SCHEDULE <br />A-2 SECTIONS, FASTENING SCHEDULE AND MATERIALS LIST <br />A-3 EXTERIOR ELEVATIONS <br />A-4 REFLECTED CEILING PLAN AND DETAILS <br />M-1 MECHANICAL PLAN AND INFORMATION <br />E-1 ELECTRICAL PLAN AND INFORMATION <br />F-1 PLANS, NOTES, MODULAR FOUNDATION <br />GENERAL NOTES ARCHITECTURAL SYMBOLS 9739 <br />REGISTERED <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE THE WORK ARCHITECT <br />OF ALL TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT. DDETMMAIILEER <br />2. CONTRACTOR HALL 1 II�ICARS TYP., SIM., REV. <br />C ORS VERIFY CONDITIONS AT THE SITE AND REPORT ALL A3.0 (IF USED) KELLI GARDINER SMITH <br />DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. SIM. STATE of WASHINGTON <br />3. CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF SHEET NUMBER WHERE <br />THE WORK AS INDICATED ON ALL DRAWINGS. IF ERROR IN LAYOUT, <br />DETAIL IS LOCATED <br />DIMENSIONS, OR DETAILS ARE FOUND BETWEEN ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL OR LANDSCAPE DRAWINGS • • •IDENTIFICATION:C <br />CONTACT THE ARCHITECT IMMEDIATELY BEFORE PROCEEDING. N__ <br />SECTION NUMBER <br />4. REGULATIONS, STANDARDS, CONSTRUCTION, MATERIALS AND SHEET NUMBER WHERE Madison E S 2021 <br />REQUIREMENTS FOR INSTALLATION OF MATERIALS SHALL CONFORM AND BE SECTION IS LOCATED <br />GOVERNED BY THE EDITION OF THE CODE IDENTIFIED IN THE CODES _ Portables <br />SECTION OF THIS SHEET. <br />5, REFERENCING DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT r A2 DETAIL NUMBER <br />APPLICATION OF DRAWINGS OR DETAILS. FOR <br />_ � A7.5 <br />6. MATERIALS AND FINISHES LISTED ON INTERIOR AND EXTERIOR ELEVATIONS SHEET NUMBER WHERE }} Public <br />ARE FOR GENERAL INFORMATION AND CONVENIENCE OF THE CONTRACTOR. DETAIL IS LOCATED EVe re l4 <br />IN ADDITION TO MATERIALS AND FINISHES INDICATED OR SPECIFIED <br />ELSEWHERE IN THE DOCUMENTS. Schools <br />A INTERIOR ELEVATION NUMBER Schools <br />�7 <br />7. HEIGHT DIMENSIONS ARE GIVEN FROM FINISHED FLOOR WHERE INDICATED, <br />OR RELATIVE TO DATUM NOTED ON DRAWINGS. D2-- INTERIOR ELEVATION <br />D B VIEW DESIGNATION /� T <br />8. N.I.C. EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS. CONTRACTOR A5.1 A <br />IS RESPONSIBLE FOR COORDINATING INSTALLATION AND PERFORMING WORK SHEET NUMBER WHERE <br />AS REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT C ELEVATION IS LOCATED G <br />INSTALLATION. 616 Pecks Dr <br />9. F.O.I.C. EQUIPMENT IS FURNISHED BY OTHERS AND INSTALLED AS PART OF DOOR NUMBER BASED Everett WA 98203 <br />THIS WORK. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE 101 ON ROOM NUMBER <br />WORK AS REQUIRED FOR INSTSALLATION. '4 DOOR LETTER PERMIT SET <br />10. DO NOT SCALE DRAWINGS: CONTACT ARCHITECT FOR ANY NEEDED 05/1 0/2021 <br />CLARIFICATION. WINDOW AND RELITE TYPE <br />AA <br />11. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER This drawing is: <br />MEMBRANE AT THE FLOOR SLAB, WALLS, AND ROOF. BACKER ROD, SEALANT, 1. Copyright 2021 Dykeman, Inc. <br />AND OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND ROOM ROOM NAME 2. The Architect's Instrument of Professional Service. <br />ALL EXTERIOR DOORS, WINDOW PENETRATIONS, AND OTHER AREAS OF NAME 3. For use on this project only. Obtain Architect's E <br />POTENTIAL AIR INFILTRATION, INCLUDING STRUCTURAL, MECHANICAL, AND written permission for any other use or reproduction. <br />ELECTRICAL PENETRATIONS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE 101 ROOM NUMBER <br />TO VAPOR BARRIER OR REPLACE THEM PRIOR TO COVER AS APPROVED. PROJECT <br />12. WHERE EXTERIOR CONCRETE WALKS AND LANDINGS ABUT BUILDING, THEY WS00 WALL TYPE TAG <br />SHALL BE SLOPED AWAY FROM THE BUILDING AS NOTED, BUT IN NO CASE 2021-01 3 <br />LESS THAN 1/8 :12 . <br />BUILDING CODE INFO REVISION IDENTIFICATION <br />MARK DATE DESCRIPTION <br />OCCUPANCY: E REVISION CLOUD <br />TYPE OF CONSTRUCTION: VB, NON-SPRINKLERED (PORTABLE) <br />BLDG. SQ. FT: 887 SF, ONE STORY WORK POINT, CONTROL POINT, <br />�_--- OR DATUM POINT <br />BLDG/ HEIGHT: 15' - 9" <br />PORTABLE CLASSROM CLUSTER: 887 < 6,000 SIF <br />INDICATES DIRECTION OF <br />OCCUPANT LOAD:. 45 •••••••.. � MAGNETIC NORTH <br />MOAMOM1111111111110111100iftntom <br />M CM. I1111001N . _ • , <br />NORTHACREAGE PRINCIPAL IN CHARGE:1 KGS <br />AA1101�11aMlf PROJECT MANAGER: ZAH <br />9.64 ACRES © PROJECT ARCHITECT: <br />Q SEE1"/IIAMQOUi JOB CAPTAIN: DDF <br />The issuance of a permit shall not APPROVED DRAWING TITLE: <br />be construed as authority to violate, PUBLIC WORKS DEPARTMENT <br />A <br />cancel or set aside any provision of <br />the Evert Fire Code or other BY TITLE SHEET PROJECT <br />applicable emulations orlawL The DATE�EVIEWIED � <br />issuance of a P bnw an CITY OF EVEREReA1T INFORMATION <br />cones documuNt and aher <br />data shsb not RtnwWnt tAt Fire Code <br />011W ll'im m fht correction DRAWING <br />Of errors. <br />NG, AND <br />r° <br />6Z-- G , <br />ning Set <br />A I <br />v <br />,;q` ur� R <br />