My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
616 PECKS DR 2021 Plans 2022-11-29
>
Address Records
>
PECKS DR
>
616
>
Plans
>
616 PECKS DR 2021 Plans 2022-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 1:06:28 PM
Creation date
10/19/2021 10:32:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PECKS DR
Street Number
616
Permit
B2105-023
Year
2021
Notes
New 887sf portable P1, landing, and ramp to be installed
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />M <br />N <br />11 <br />E1 <br />D <br />(C <br />19 <br />w <br />5' X 6LANDING AND 30' X 4'RAMP; <br />SLOPE RAMP NO GREATER THAN 1:12 <br />6" CRUSHED ROCK BUILDING PAD TO <br />EXTEND 24" BEYOND FACE OF BUILDING <br />AND 12" BEYOND FACE OF RAMPS <br />FIRE EXTINGUISHER MOUNTED <br />ON INSIDE WALL NEXT TO DOOR <br />a <br />GENERAL NOTES <br />1. INSTALLATION TO BE IN ACCORDANCE WITH THE STRUCTURAL DESIGN AND <br />CALCULATIONS OF THE STRUCTURAL ENGINEER. <br />2. NEW PORTABLE CLASSROOMS ARE TO BE CONNECTED TO THE MAIN FIRE <br />ALARM SYSTEM. <br />3. RAMP SHALL CONFORM WITH THE WASHINGTON STATE BARRIER FREE DESIGN <br />REQUIREMENTS AND APPLICABLE FEDERAL, STATE AND LOCAL CODES AND <br />REGULATIONS, <br />4. PROVIDE AN UNDER FLOOR ACCESS PANEL WITH A MINIMUM CLEAR OPENING <br />WIDTH OF 13" x 24". THE OPENING MUST BE COVERED WITH A DOOR OR SCREEN. <br />5. PROVIDE UNDER FLOOR VENTILATION AT THE RATE OF 1 SQUARE FOOT NET <br />FREE AREA FOR EACH 150 SQUARE FEET OF UNDER FLOOR AREA. VENTS ARE <br />TO BE LOCATED TO PROVIDE CROSS VENTILATION. COVER VENTS WITH 1/4" <br />CORROSION RESISTANT WIRE. <br />6. ALL CONSTRUCTION IS SUBJECT TO FIELD INSPECTIONS, CORRECTIONS AND <br />FINAL FIELD APPROVAL TOGETHER WITH ISSUANCE OF A CERTIFICATE OF <br />OCCUPANCY PRIOR TO THE BUILDING BEING OCCUPIED. <br />Z. AN APPROVED SET OF PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES <br />DURING CONSTRUCTION. <br />8. PLACE ONE TYPE 2A-1 OBC FIRE EXTINGUISHER IN EACH PORTABLE. MOUNT AT <br />MAX. 54" AFF AND PLACE ADJACENT TO DOOR. <br />9. ROOF DRAINAGE TO BE VIA ALUMINUM GUTTERS AND (4) DOWNSPOUTS AT EACH <br />BUILDING CORNER. THE DOWNSPOUTS WILL DRAIN TO SPLASH PANS WHICH <br />WILL DRAIN TO EXISTING DRAINAGE. PROVIDE POSITIVE DRAINAGE AWAY FROM <br />THE PORTABLE CLASSROOM AND ALL ADJACENT STRUCTURES. <br />10. PORTABLE CONTRACTOR TO PAINT BUILDING SKIRT TO MATCH EXISTING BASE <br />AND TRIM COLOR. <br />11. REMOVE ALL VEGETATION AND ORGANICS FROM BUILDING PAD AREA. BUILDING <br />PAD TO EXTEND 24" BEYOND FACE OF BUILDING AND 12" BEYOND FACE OF <br />RAMPS, LANDINGS AND STAIRS. PROVIDE A 6" THICK CRUSHED ROCK BASE. <br />12. EXTERIOR PAINT COLORS: <br />COLUMBIA PAINT & COATINGS <br />HI -PERFORMANCE POLAR-KOTE SATIN <br />FASCIA: 0133 <br />CORNER TRIM: 0133 <br />WINDOW TRIM: 0133 <br />SIDING BODY: 0133 <br />EXT. DOOR & FRAME: 0133 <br />GUTTERS: BEAVER BROWN <br />II <br />0 <br />0 4° 6° 16° <br />PARTIAL ITAmlm��� 4 <br />1/8" = 1"-01' Scale. 1/8" = 1"-0" NORTH <br />xLx!'4'.;'S�+r� <br />11 <br />S 2021 <br />Madison <br />J '€ a.w <br />tf k1 <br />��, �� y 'a b l e <br />� w'h <br />Everett Public <br />Schools <br />� • � !� j � �Y 5 � t� f�.il '�� i � . <br />` 3 <br />PERMIT ", E <br />5 3 <br />2021 <br />This drawing is: <br />1. Copyright 2021 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's S <br />written permission for any other use or reproduction. <br />MARK DATE DESCRIPTION <br />0 <br />PARTIAL SITE S .: PLAN <br />PORTABLES <br />1 <br />0 <br />Is <br />5 <br />4t VILK h <br />RENEWED FOR PERMIT <br />
The URL can be used to link to this page
Your browser does not support the video tag.