Laserfiche WebLink
I <br />M <br />N <br />11 <br />E1 <br />D <br />(C <br />19 <br />w <br />5' X 6LANDING AND 30' X 4'RAMP; <br />SLOPE RAMP NO GREATER THAN 1:12 <br />6" CRUSHED ROCK BUILDING PAD TO <br />EXTEND 24" BEYOND FACE OF BUILDING <br />AND 12" BEYOND FACE OF RAMPS <br />FIRE EXTINGUISHER MOUNTED <br />ON INSIDE WALL NEXT TO DOOR <br />a <br />GENERAL NOTES <br />1. INSTALLATION TO BE IN ACCORDANCE WITH THE STRUCTURAL DESIGN AND <br />CALCULATIONS OF THE STRUCTURAL ENGINEER. <br />2. NEW PORTABLE CLASSROOMS ARE TO BE CONNECTED TO THE MAIN FIRE <br />ALARM SYSTEM. <br />3. RAMP SHALL CONFORM WITH THE WASHINGTON STATE BARRIER FREE DESIGN <br />REQUIREMENTS AND APPLICABLE FEDERAL, STATE AND LOCAL CODES AND <br />REGULATIONS, <br />4. PROVIDE AN UNDER FLOOR ACCESS PANEL WITH A MINIMUM CLEAR OPENING <br />WIDTH OF 13" x 24". THE OPENING MUST BE COVERED WITH A DOOR OR SCREEN. <br />5. PROVIDE UNDER FLOOR VENTILATION AT THE RATE OF 1 SQUARE FOOT NET <br />FREE AREA FOR EACH 150 SQUARE FEET OF UNDER FLOOR AREA. VENTS ARE <br />TO BE LOCATED TO PROVIDE CROSS VENTILATION. COVER VENTS WITH 1/4" <br />CORROSION RESISTANT WIRE. <br />6. ALL CONSTRUCTION IS SUBJECT TO FIELD INSPECTIONS, CORRECTIONS AND <br />FINAL FIELD APPROVAL TOGETHER WITH ISSUANCE OF A CERTIFICATE OF <br />OCCUPANCY PRIOR TO THE BUILDING BEING OCCUPIED. <br />Z. AN APPROVED SET OF PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES <br />DURING CONSTRUCTION. <br />8. PLACE ONE TYPE 2A-1 OBC FIRE EXTINGUISHER IN EACH PORTABLE. MOUNT AT <br />MAX. 54" AFF AND PLACE ADJACENT TO DOOR. <br />9. ROOF DRAINAGE TO BE VIA ALUMINUM GUTTERS AND (4) DOWNSPOUTS AT EACH <br />BUILDING CORNER. THE DOWNSPOUTS WILL DRAIN TO SPLASH PANS WHICH <br />WILL DRAIN TO EXISTING DRAINAGE. PROVIDE POSITIVE DRAINAGE AWAY FROM <br />THE PORTABLE CLASSROOM AND ALL ADJACENT STRUCTURES. <br />10. PORTABLE CONTRACTOR TO PAINT BUILDING SKIRT TO MATCH EXISTING BASE <br />AND TRIM COLOR. <br />11. REMOVE ALL VEGETATION AND ORGANICS FROM BUILDING PAD AREA. BUILDING <br />PAD TO EXTEND 24" BEYOND FACE OF BUILDING AND 12" BEYOND FACE OF <br />RAMPS, LANDINGS AND STAIRS. PROVIDE A 6" THICK CRUSHED ROCK BASE. <br />12. EXTERIOR PAINT COLORS: <br />COLUMBIA PAINT & COATINGS <br />HI -PERFORMANCE POLAR-KOTE SATIN <br />FASCIA: 0133 <br />CORNER TRIM: 0133 <br />WINDOW TRIM: 0133 <br />SIDING BODY: 0133 <br />EXT. DOOR & FRAME: 0133 <br />GUTTERS: BEAVER BROWN <br />II <br />0 <br />0 4° 6° 16° <br />PARTIAL ITAmlm��� 4 <br />1/8" = 1"-01' Scale. 1/8" = 1"-0" NORTH <br />xLx!'4'.;'S�+r� <br />11 <br />S 2021 <br />Madison <br />J '€ a.w <br />tf k1 <br />��, �� y 'a b l e <br />� w'h <br />Everett Public <br />Schools <br />� • � !� j � �Y 5 � t� f�.il '�� i � . <br />` 3 <br />PERMIT ", E <br />5 3 <br />2021 <br />This drawing is: <br />1. Copyright 2021 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's S <br />written permission for any other use or reproduction. <br />MARK DATE DESCRIPTION <br />0 <br />PARTIAL SITE S .: PLAN <br />PORTABLES <br />1 <br />0 <br />Is <br />5 <br />4t VILK h <br />RENEWED FOR PERMIT <br />