616 PECKS DR 2021 Plans 2022-11-29
>
Address Records
>
PECKS DR
>
616
>
Plans
>
616 PECKS DR 2021 Plans 2022-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 1:06:28 PM
Creation date
10/19/2021 10:32:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PECKS DR
Street Number
616
Permit
B2105-023
Year
2021
Notes
New 887sf portable P1, landing, and ramp to be installed
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />® EXISTING ELECTRICAL TO BE REMOVED <br />EXISTING ELECTRICAL TO REMAIN <br />NEW ELECTRICAL WORK <br />ENLARGED FLAN BOUNDARY <br />IN <br />POWER <br />SWITCHBOARD/SWITCHGEAR <br />PANELBOARD, FLUSH -MOUNTED <br />— <br />PANELBOARD, SURFACE -MOUNTED <br />(FRONT) <br />T <br />TRANSFORMER <br />MOTOR CONNECTION <br />DISCONNECT SWITCH, NON -FUSED <br />DISCONNECT SWITCH, FUSED <br />B <br />ENCLOSED CIRCUIT BREAKER <br />B VFD <br />VARIABLE FREQUENCY DRIVE <br />M <br />MANUAL MOTOR STARTER WITH THERMAL <br />OVERLOADS <br />COMBINATION STARTER/DISCONNECT <br />MAGNETIC STARTER <br />EQUIPMENT CONNECTION - CONFIRM CONNECTION <br />WITH EQUIPMENT A, . R, R <br />PUSHBUTTON CONTROLLER <br />® (SINGLE OR MULTIPLE BUTTONS) <br />IN <br />RACEWAY AND BOXES <br />J JUNCTION BOX <br />OF FURNITURE WALL FEED OUTLET BOX <br />PB FULL BOX <br />ED <br />XX (WHERE INDICATED, SUBSCRIPT INDICATES PULL BOX TYPE) <br />HANDHOLE <br />HH <br />XX (WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE) <br />VAULT <br />(WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE) <br />XX <br />FLOORBOX (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR <br />A BOX TYPE) <br />POKE-THRU (WHERE INDICATED, SUBSCRIPT INDICATES <br />®A POKE-THRU TYPE) <br />POWER POLE, FLOOR TO CEILING <br />SURFACE METAL RACEWAY <br />RACEWAY CONCEALED IN WALL OR IN CEILING <br />(EXPOSED IN UNFINISHED AREAS) <br />RACEWAY RUN BELOW FLOOR OR BELOW GRADE <br />r,1 RACE AV gLEEVE KITH BUSHING <br />EQUIPMENT ENCLOSURE <br />BUS <br />TERMINAL/LUG <br />ST SHUNT TRIP <br />FIRE STOPPING SLEEVE <br />0GROUND FAULT PROTECTION <br />CABLE TRAY, 12"W X 4"H OVERHEAD, UNLESS <br />� ............ OTHERWISE NOTED <br />EPM ELECTRONIC POWER METER <br />CABLE TRAY, OVERHEAD LADDER TYPE SPD SURGE PROTECTIVE DEVICE <br />HOMERUN TO PANEL GROUND <br />HA-3 (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) <br />16 <br />-'—(GAUGE OF WIRE OTHER THAN A)NG#12) <br />12,241 AVAILABLE FAULT CURRENT (SYMMETRICAL) TAG <br />NUMBER OF CONDUCTORS <br />(GROUND CONDUCTOR) 225 FEEDER TAG <br />(PHASE CONDUCTORS) <br />(NEUTRAL CONDUCTOR) <br />PAD MOUNT TRANSFORMER <br />GROUNDING <br />® 480V <br />G GROUNDING CONDUCTOR 2osY TRANSFORMER <br />Ya 120V <br />® GROUND ROD <br />® GROUNDING BUSBAR PANELBOARD - MAIN LUGS ONLY <br />EQUIPMENT GROUNDING CONNECTION <br />GROUNDING STRAP <br />PANELBOARD - MAIN CIRCUIT BREAKER <br />INTERCOM AND CLOCK SYSTEMS <br />INTERCOM AND CLOCK, WALL MOUNTED <br />C ANALOG CLOG, WALL MOUNTED <br />G_,�-(WHERE APPLICABLE WIRE GUARD) <br />C DIGITAL CLOCK, WALL MOUNTED <br />i SPEAKER, CEILING MOUNTED <br />pp_,_ -(WHERE APPLICABLE IF SPEAKER W/ TELECOM DEVICE) <br />I SPEAKER, WALL MOUNTED <br />IP---(WHERE APPLICABLE IP SPEAKER W/ TELECOM DEVICE) <br />I SPEAKER EXTERIOR RATED, WALL MOUNTED <br />IP�-(WHERE APPLICABLE IP SPEAKER W/ TELECOM DEVICE) <br />B EXTERIOR BELL, WALL MOUNTED <br />cs <br />CALL OR PANIC SWITCH, WALL MOUNTED <br />V VOLUME CONTROL, WALL MOUNTED <br />B DOORBELL, WALL MOUNTED <br />TELECOMMUNICATIONS <br />„Ia a E!9' O$ •eI 3UNi4 ..A ? IONS SYSTEM <br />. 1 .3. 9 t=' <br />TELECOMMUNICATIONS DEVICE <br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />(W = TELECOMMUNICATIONS WALL PHONE MTD AT +48" AFF) <br />(B = BLANK COVER PLATE) <br />(F = MODULAR FURNITURE DEVICE) <br />Y (AC = ABOVE COUNTER DEVICE) <br />(S = SURFACE MOUNT) <br />(WAP = WALL MOUNTED WIRELESS ACCESS POINT DATA DEVICE) <br />ABOVE CEILING TELECOMMUNICATIONS DEVICE <br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />WAP (WAP = WIRELESS ACCESS DEVICE) <br />(SV = SECURITY VIDEO CAMERA) <br />FIRE RESISTANT 3/4" PLYWOOD BACKBOARD <br />TWO -POST EQUIPMENT RACK <br />3.65"DOUBLE-SIDED VERTICAL MANAGEMENT <br />6" DOUBLE -SIDED VERTICAL MANAGEMENT <br />12" DOUBLE -SIDED VERTICAL MANAGEMENT <br />WALL MOUNTED ENCLOSURE <br />FLOOR MOUNTED SERVER ENCLOSURE <br />110 BLOCK WITH LEGS <br />66 BLOCK <br />t � ALL SYMBOLS MAY APPEAR ON I THE D RAW I N'. <br />'A'IV1/0LII <br />Madison ES 2021 <br />8 <br />Portables <br />2021-013 <br />MARK DATE DESCRIPTION <br />pp ; <br />a.4_ 1 . Y 1._.e E - ' N , d <br />INDEX& DRAWING <br />DIl <br />III <br />W41 <br />i <br />ik <br />N <br />