GENERAL NOT -"S: <br />GENERAL CONDITIONS: <br />1, DO NOT SCALE DRAWINGS. <br />2. REPETITIVE FEATURES MAY BE DRAWN OR CALLED OUT ONCE, BUT SHALL BE COMPLETELY <br />PROVIDED AS IF DRAWN IN FULL. <br />3, ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY AND SHALL BE IN ACCORDANCE WITH <br />ALL MANUFACTURERS' SPECIFICATIONS, DIRECTIONS AND RECOMMENDATIONS. THE WORK <br />SHALL ALSO BE IN STRICT CONFORMANCE WITH INDUSTRY STANDARDS AND COMPLY WITH <br />SOUND ENGINEERING AND CONSTRUCTION PRACTICES. THE CONTRACTOR SHALL REPLACE <br />PORTIONS OF THE INSTALLED WORK THAT DOES NOT MEET THESE REQUIREMENTS AT THEIR <br />EXPENSE. <br />4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND <br />LOCAL LAWS, AND IN ACCORDANCE WITH CURRENT CODE REQUIREMENTS. <br />5. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED LOCAL JURISDICTION INSPECTIONS <br />AND SPECIAL INSPECTIONS. THE CONTRACTOR SHALL PROVIDE COPIES OF THE INSPECTION <br />REPORTS TO THE OWNER. <br />6, ALL NEW AND/OR REPLACEMENT MATERIALS SHALL BE EQUAL OR BETTER IN KIND AS <br />EXISTING MATERIALS. <br />1. THE CONTRACTOR SHALL FILE FOR AND SHALL OBTAIN THE PERMITS FOR ALL WORK IF <br />REQUIRED BY ANY GOVERNMENTAL AGENCIES. <br />8. MECHANICAL AND ELECTRICAL TO BE FILED UNDER SEPARATE PERMITS AND SHALL BE <br />BIDDER DESIGNED. MECHANICAL AND ELECTRICAL REPAIR DESIGN TO BE PERFORMED BY <br />LICENSED AND QUALIFIED MECHANICAL AND ELECTRICAL CONTRACTORS. ALL NEW <br />MECHANICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE <br />ENERGY CODE. THE COST OF SUCH MECHANICAL PERMITS SHALL BE INCLUDED IN THE BID. <br />9. CONTACT THIS OFFICE AT (206) 281-1500 IF ANY DAMAGE IS FOUND OUTSIDE THIS SCOPE OF <br />WORK DURING DEMOLITION OR ANY VARIATIONS TO THE SITE OR EXISTING BUILDING(S) ARE <br />FOUND DURING THE CONSTRUCTION WORK <br />SITE CONDITIONS, SAFETY AND DEh1 ITf : <br />10, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS AT THE JOB SITE, <br />INCLUDING THE SAFETY OF ALL PERSONS AT THE JOB SITE DURING THE PERFORMANCE OF THE <br />WORK. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL <br />WORKING HOURS. <br />11. THE CONTRACTOR SHALL PROVIDE ACCEPTABLE SAFETY AND SECURITY MEASURES AND <br />SHALL MAINTAIN SAFETY AND SECURITY AT THE JOB SITE DURING THE ENTIRE COURSE OF THE <br />PROJECT. <br />12,. THE CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADES AND OTHER FORMS OF <br />PROTECTION TO PROTECT THE PUBLIC FROM INJURY DUE TO DEMOLITION AND REPAIR WORK. <br />BARRICADES ARE TO REMAIN IN PLACE AFTER DEMOLITION WORK HAS BEEN COMPLETED <br />AND THROUGHOUT THE DURATION OF THE WORK <br />13. THE CONTRACTOR SHALL REASONABLY SECURE SCAFFOLDING, WORK AREAS, BUILDING <br />MATERIALS AND TOOLS FROM ACCESS TO THE PUBLIC AT ALL TIMES. <br />14, THE REQUIRED AND/OR IMPLIED DUTY OF PACIFIC ENGINEERING TECHNOLOGIES, INC., TO <br />CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE DOES NOT, AND IS <br />NOT INTENDED TO, INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY <br />MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE, <br />15. THE CONTRACTOR AND THE SUB -CONTRACTORS SHALL VISIT THE SITE TO REVIEW THE <br />EXISTING SITE, BUILDING CONDITIONS, AND FEATURES, INCLUDING, BUT NOT LIMITED TO: <br />GRADES, DIMENSIONS, ACCESS TO THE WORK, POWER ACCESS, STAGING, REFUSE DISPOSAL, <br />MATERIAL STORAGE, ETC. <br />16, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION, TEMPORARY BRACING, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES IN CONNECTION WITH THE WORK <br />11. PROVIDE SCAFFOLDING AND TEMPORARY WEATHER PROTECTION FOR AREAS OF THE <br />BUILDING EXPOSED DURING CONSTRUCTION AS NECESSARY TO ACCOMPLISH THE REPAIR <br />WORK SUFFICIENTLY AND TO PREVENT WATER DAMAGE FROM OCCURRING AS THE WORK <br />PROGRESSES. <br />IS, PROPERLY PROTECT OR CAP ALL UTILITIES THAT MIGHT BE DISTURBED DUE TO DEMOLITION <br />ACTIVITY. <br />IS. PROTECT EXISTING FINISHES, FIXTURES, EQUIPMENT, ETC. THAT ARE TO REMAIN FROM DAMAGE <br />DURING CONSTRUCTION. <br />20. PRIOR TO GENERAL/SELECTIVE: DEMOLITION, THE GENERAL CONTRACTOR SHALL OBTAIN THE <br />PERMISSION OF THE OWNER TO DETERMINE WHETHER HAZARDOUS WASTES OR ASBESTOS IS <br />PRESENT IN DEMOLITION DEBRIS. SHOULD HAZARDOUS MATERIALS OR ASBESTOS BE FOUND <br />IN DEMOLITION DEBRIS, THE CONTRACTOR SHALL LEGALLY CONTAIN SUCH MATERIAL AND <br />DISPOSE OF OFF SITE AT AN APPROVED DUMP SITE AFTER OBTAINING (OWNER'S) PERMISSION <br />TO DO SO. <br />21. COORDINATE ALL DEMOLITION ACTIVITIES WITH THE OWNER. <br />22. THE CONTRACTOR SHALL TRANSPORT AND DISCARD IN A LEGAL MANNER ALL CONSTRUCTION <br />DEBRIS AND REMOVED ITEMS NOT INTENDED FOR REUSE. <br />23. INSPECT CONCEALED SPACES UNCOVERED DURING THE DEMOLITION PHASE FOR DAMAGE. <br />24. THE CONTRACTOR 1$ TO LEAVE THE SITE BROOM CLEAN FROM CONSTRUCTION RELATED <br />DEBRIS AFTER DEMOLITION WORK IS COMPLETE, AT THE: END OF EACH DAY AND AT THE END <br />OF THE PROJECT. <br />CONSTRUCTION: <br />25, ALL SUCH PRODUCTS AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, INDUSTRY <br />STANDARDS AND CODE REQUIREMENTS. <br />26. PROVIDE WEATHER -RESISTIVE BEHIND WALL CLADDING IN ACCORDANCE WITH IRC R103, <br />21, PROVIDE FLASHING$ FOR EXTERIOR BUILDING COMPONENTS IN ACCORDANCE WITH IRC R303, <br />28. THE CONTRACTOR SHALL VERIFY THAT ALL WATERPROOFING COMPONENTS ARE COMPATIBLE <br />WITH EACH OTHER, I.E. SEALANT$ AND BACKER ROD, SEALANTS, AND SELF ADHESIVE (PEEL <br />'N' STICK) MEMBRANE, ETC. <br />29. NEW THERMAL INSULATION MUST COMPLY WITH THE CURRENT EDITION OF THE WASHINGTON <br />STATE ENERGY CODE. <br />30. ALL NEW WINDOWS, SKYLIGHTS AND EXTERIOR DOORS MUST COMPLY WITH THE CURRENT <br />EDITION OF THE WASHINGTON STATE ENERGY CODE. <br />31. WINDOWS, SLIDING GLASS DOORS AND DOORS SHALL BE INSTALLED WITH PENETRATION <br />FLASHINGS AND IN ACCORDANCE IRC R103.4 AND WITH ASTM E 2112, <br />32. HOLES FOR WIRING AND PLUMBING PENETRATIONS THAT PASS THROUGH FIRE -RESISTANCE <br />RATED ASSEMBLIES ARE TO BE SEALED WITH A FIRE RATED EXPANDING FOAM OR SEALANT. <br />THE FOAM OR SEALANT IS TO BE IN ACCORDANCE WITH ASTM E $14 OR UL 1419 WITH AN F AND <br />T RATING NOT LESS THAN THE ASSEMBLY RATING IN ACCORDANCE WITH IRC 302.4. <br />33. ALL NEW WOOD PLATES, NAILING STRIPS, AND LEDGERS IN CONTACT WITH CONCRETE OR <br />EXPOSED TO THE WEATHER SHALL BE PRESSURE PRESERVATIVE TREATED. CUT ENDS, ETC., <br />SHALL BE PAINTED WITH (2) COATS OF WOOD PRESERVATIVE PANT. <br />34, PROVIDE DIFFERENTIAL METAL PROTECTION TO PREVENT GALVANIC ACTION WHERE OCCURS. <br />35, ALL NEW PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH WASHINGTON STATE <br />PLUMBING CODE AMENDMENT RCW 1921.110. <br />UILD INCH ENVELOPE SPECIFICATIONS: <br />ENERGY CODE: <br />PROVIDE THERMAL INSULATION IN ACCORDANCE WITH 2O15 WASHINGTON STATE <br />ENERGY CODE IN ACCORDANCE WITH RESIDENTIAL TABLE R402.1.1 <br />ATTIC/ROOF <br />R-4S <br />EXTERIOR WALL <br />R-15 (2x4 FRAMING, EXIST.) <br />HEADERS <br />R-10 <br />FLOOR <br />R-30 <br />ACCESS HATCHES AND DOORS <br />SAME AS SPACE ACCESSING <br />HVAC DUCTS (ATTIC) <br />R-8 <br />EXHAUST DUCTS (ATTIC) <br />R-4 <br />HOT WATER PIPES <br />R-4 <br />GLAZING U=0.30 MAX. <br />DOORS U = 0.30 MAX. <br />A PERMANENT CERTIFICATE LISTING THE PREDOMINANT R-VALUES, WINDOW AND DOOR <br />U-VALUES, DUCT AND AIR LEAKAGE TESTING RESULTS SHALL BE POSTED ADJACENT <br />TO THE ELECTRICAL PANEL. <br />WINDOWS AND SLIDING GLASS DOORS (R402.4.3): <br />WINDOWS SHALL MEET THE FOLLOWING SPECIFICATIONS: <br />1. SHALL BE NRFC 100 CERTIFIED. <br />2. HAVE AN AIR LEAKAGE RATE OF NO MORE THAN 0.3 CFM PER SQUARE FOOT WHEN <br />TESTED IN ACCORDANCE WITH NRFC 400 OR AAMA/WDMA/CSA 101/1.5.2/A440, <br />XTERIOR DOORS (R402.4.3): <br />EXTERIOR DOORS SHALL HAVE AN AIR LEAKAGE RATE OF NO MORE THAN 0.5 CFM <br />PER SQUARE FOOT WHEN TESTED IN ACCORDANCE WITH NRFC 400 OR <br />AAMA/WDMA/CSA 101/I.6.2/A440. <br />VAPOR RETARDER$ (IR402.1.5): <br />PROVIDE A VAPOR RETARDER WITH A MINIMUM ONE PERM DRY CUP RATING ON <br />INTERIOR (WARM) SIDE OF CEILINGS, WALLS AND FLOORS THAT SEPARATE A HEATED <br />FROM AN UNHEATED SPACE. <br />VAPOR RETARDER SHALL BE 6 MIL POLYETHYLENE SHEETING. PVA PAINT HAVING A <br />PERMEANCE RATING OF ONE PERM DRY CUP RATING OR LESS IS ACCEPTABLE ON <br />WALLS AND CEILING. <br />ATTACH POLYETHYLENE SHEETING TO THE UNDERSIDE OF CEILING JOISTS AND <br />INTERIOR FACE OF WALL STUDS BY APPLYING CONTINUOUS BEAD OF SEALANT TO <br />EACH JOIST OR STUD, <br />INSTALL POLYETHYLENE IN CONTINUOUS SHEETS AS MUCH AS POSSIBLE, ACROSS <br />CEILING AND WALL. WHERE LAPS DO OCCUR, THE LAPS SHALL BE 6" MINIMUM AND <br />SEALED WITH TAPE OR SEALANT. CONTINUOUSLY SEAL BOTTOM AND TOP EDGES TO <br />WALL AND CEILING TERMINATIONS. SEAL VAPOR RETARDER TO ANY CONDUIT, BOXES, ' <br />PIPING OR OTHER ITEMS WITHIN THE CEILING AND WALL SYSTEM, REPAIR ANY TEARS <br />OR PENETRATIONS OF VAPOR RETARDER WITH APPROVED TAPE PRIOR TO <br />INSTALLATION OF DRYWALL. <br />CRAWL f2PACE VAPOR RETARDER: <br />PROVIDE A MINIMUM 10 MIL THICK BLACK POLYETHYLENE SHEET OR SIMILAR CLASS I <br />WITH A VAPOR RETARDER WITH A 0.1 PERM OR LESS RATING IN ACCORDANCE WITH <br />ASTM E 96. <br />THE VAPOR RETARDER SHALL BE PLACED OVER THE EXPOSED EARTH IN THE CRAWL <br />SPACE, LAP JOINTS SHALL BE 12" AND SEALED AND SHALL EXTEND UP VERTICAL <br />SURFACES 6" MINIMUM AND BE SEALED TO THE FOUNDATION WALLS. <br />MECHANICAL VENTILATION: <br />PROVIDE SOURCE SPECIFIC FANS IN ACCORDANCE WITH WASHINGTON STATE <br />MECHANICAL CODE. <br />SOURCE SPECIFIC: <br />RANGE HOOD 100 CFM <br />BATHROOMS 50 CFM 1.0 SONE MAX. <br />LAUNDRY ROOMS 50 CFM 1.0 SONE MAX. <br />EXHAUST DUCT TERMINATION LOCATIONS ON THE EXTERIOR OF THE RESIDENCE ARE <br />TO BE LOCATED A MINIMUM OF V-0" FROM WINDOW AND DOOR OPENINGS. <br />LIGHTING (R404.1)., <br />A MINIMUM OF 15 PERCENT OF ALL NEW PERMANENTLY INSTALLED BULBS IN LIGHTING <br />FIXTURES SHALL BE NIGH -EFFICACY BULBS. <br />RECESSED LIGHTING INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE TYPE <br />IC -RATED AND CERTIFIED UNDER E 263 AS HAVING AN AIR LEAKAGE RATE NOT MORE <br />THAT 2.0 CFM WHEN TESTED AT A IB1 PSF (15 PA) AND SHALL HAVE A LABEL <br />ATTACHED SHOWING COMPLIANCE. <br />FIR PROTECTION NOTES: <br />SMOKE DETECTORS: <br />SMOKE DETECTORS SHALL CONFORM TO REQUIREMENTS OF IRC SECTION R314 AND THE <br />FOLLOWING SPECIFICATIONS: <br />• SMOKE DETECTORS SHALL BE HARD WIRED TO THE BUILDING ELECTRICAL SYSTEM AND <br />SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM <br />WILL ACTIVATE ALL OF THE ALARMS. <br />• ALARMS SHALL COMPLY WITH UL 211 <br />• ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 12 AND MANUFACTURER'S <br />RECOMMENDATIONS <br />SMOKE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />• IN EACH BEDROOM. <br />• IN THE IMMEDIATE VICINITY OUTSIDE EACH BEDROOM. <br />CARBON MONOXIDE ALARMS: <br />PROVIDE CARBON MONOXIDE ALARMS IN ACCORDANCE WITH THE IRC, SECTION R315. <br />• SHALL BE CONNECTED TO THE BUILDINGS POWER SOURCE. <br />• ALARMS SHALL BE INSTALLED IN ACCORDANCE THE MANUFACTURER'S INSTALLATION <br />RECOMMENDATIONS. <br />• COMBINATION CARBON MONOXIDE / SMOKE ALARMS SHALL COMPLY WITH UL 2034 AND <br />UL 211. <br />CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />• IN THE IMMEDIATE VICINITY OUTSIDE EACH BEDROOM. <br />• ON EACH FLOOR OF THE BUILDING. <br />WORK THIS PERMIT, <br />SHOWN SHADED <br />le <br />SITE PLAN � I THE INFORMATION ON THIS SITE PLAN IS <br />SCALE: I" = 20'-0" �� SCHEMATIC AND HAS BEEN DERIVED <br />FROM THE SITE PLAN INFORMATION ON <br />TRUE PROJECT RECORD WITH SNOHOMISH COUNTY, <br />NORTH NORTH AERIAL PHOTOGRAPHS AND SITE VISIT. <br />STRUCTURAL NOTES CCONTJ: <br />GENERAL WOOD FRAMING NOTES: <br />1, MINIMUM NAILING SHALL BE IN ACCORDANCE WITH FASTENING SCHEDULE TABLES <br />23-25 IN ICC-ES EVALUATION REPORT ESR-1535. <br />2, PROVIDE CONTINUOUS 2x SOLID BLOCKING OR A RIM JOIST FOR FRAMING MEMBERS <br />AT ALL SUPPORTS, <br />3. FLUSH BEAMS (FB) NOT CALLED OUT ON THE PLANS SHALL BE DOUBLE'JOISTS, <br />4. PROVIDE DOUBLE JOISTS UNDER PARTITIONS EXTENDING 1/2 OR MORE OF THE JOIST <br />SPAN. <br />5. ALL COLUMNS NOT CALLED OUT ON THE PLANS AND/OR SCHEDULE SHALL BE (2) <br />STUDS SPIKED TOGETHER WITH 10d COMMON NAILS AT 6" O.G., STAGGERED WITH <br />ADJACENT NAILS DRIVEN FROM OPPOSITE SIDES. <br />6. ALL LAMINATED BEAMS AND HEADERS SHALL BE SPIKED TOGETHER WITH 10D <br />NAILS AT 6" O.C. ALONG EACH EDGE UNLESS OTHERWISE NOTED. <br />1. PROVIDE CUT WASHERS FOR ALL BOLT HEADS AND NUTS BEARING ON WOOD, <br />6. PROVIDE SILL SEAL/GASKET BETWEEN LUMBER AND CONCRETE OR MASONRY, <br />SEALER/GASKET SHALL PROVIDE A CAPILLARY BREAK. <br />S. ALL DOOR AND WINDOW HEADERS NOT CALLED OUT ON THE PLANS SHALL BE (2) <br />2x8 OR A 3 1/2"x 1 1/4" LAMINATED STRAND LUMBER (LSL) WITH ONE CRIPPLE AND <br />ONE STUD EACH END FOR OPENINGS 4'-0" WIDE OR LESS, AND (2) 2x12 WITH TWO <br />CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 4'-0" WIDE, <br />10, PROVIDE ONE LAYER OF 400 ASPHALT IMPREGNATED BUILDING PAPER AT <br />CONTACT SURFACES BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. <br />11. CURRENT IBC BUILDING CODES ARE AVAILABLE ONLINE FOR FREE PUBLIC ACCESS <br />AT CODES.ICCSAFE.ORG, <br />ROOF SHEATHING: <br />APPLY TWO LAYERS OF PLYWOOD/OSB TO MATCH EXISTING PLYWOOD AND SKIP <br />SHEATHING THICKNESS 05/32" MIN.) NAILED TO JOISTS WITH 106 NAILS AT ro" O.G. AT ALL <br />SUPPORTED PANEL EDGES AND AT 12" O.C. ALONG INTERMEDIATE SUPPORTS. NEW ROOF <br />SHEATHING TO SPAN ACROSS A MINIMUM OF THREE SUPPORTS. EXISTING SHEATHING <br />PANELS THAT ARE CUT SHALL STILL SPAN ACROSS A MINIMUM OF THREE SUPPORTS OR <br />BE REPLACED. <br />EXTERIOR WALL SHEATHING, <br />APPLY PLYWOOD/OSB TO MATCH EXISTING EXTERIOR WALL SHEATHING THICKNESS (3/5" <br />MIN.) NAILED TO STUDS WITH 10d NAILS AT 6" O.G. AT ALL SUPPORTED PANEL EDGES <br />AND AT 12" O.C. ALONG INTERMEDIATE SUPPORTS. ALL PANEL EDGES SHALL BE <br />BACKED WITH 2" NOMINAL OR WIDER FRAMING. <br />SCOPE OF LUORK SUMMA �r <br />TYFE: FIRE DAMAGE REPAIR <br />THE PURPOSE OF THESE DRAWINGS IS TO SHOW REPAIRS FOR THE DAMAGE CAUSED BY THE <br />RECENT FIRE AT THE BRADDOCK RESIDENCE IN EVERETT, WASHINGTON. <br />THE STRUCTURAL DAMAGE IS LIMITED TO THE ROOF FRAMING AND GABLE END WALL FRAMING <br />WHICH IS BEING REPLACED IN -KIND TO MATCH EXISTING. THERE ARE NO ADDITIONS OR <br />ALTERATIONS. INTERIOR FINISHES WILL BE REMOVED AND REPLACED AS REQUIRED, <br />THERE IS NO INCREASE IN THE EXISTING BUILDING FOOTPRINT. <br />EXCLUSIONS, <br />NO REVIEW HAS BEEN MADE OF THE ADEQUACY OF THE EXISTING FRAMING MEMBERS. <br />ARCHITECTURAL DETAILING SUCH AS, BUT NOT LIMITED TO: ROOFING, WEATHER -RESISTIVE <br />ASSEMBLIES, ETC. IS NOT INCLUDED IN THESE DRAWINGS. <br />Permit#: B1907-012 <br />Site Address: 3104 TU LALIP AVE <br />Owner: BRADDOCK LAURA C & ADAM J <br />Tenant: [TenNamej <br />App. Date: 7/10/2019 <br />Proposed Use: SFR DETACHED <br />Description: REPAIR DAMAGE TO EXTG SFR DUE TO FIRE <br />Reviewed By: Date: <br />Office Set Jab Site Set Fire/Planning Set <br />PrI vllence,Regio',nal <br />�w> <br />�, to <br />�M1 <br />U <br />pc <br />_ICINITY MAFZFZ <br />SCALE: N.T.S. +� <br />I <br />f <br />AS,iESSOR'S No.: 005ro19Q,i1 oom I <br />ClTvi OF:EVE ;.ETT <br />LEGAL D"MSCRIPtION: Permit Services <br />RooBUCKER PARK ADD TO EVERETT BLK 011 D-01 - NELY 100FT OF LOT and trusses r p designed <br />2 t THE NELY 100FTOF THE NWLY 1/2 OF LOT 3 and to licensed <br />prepared by <br />a State li+rensed structural <br />engineer. <br />SUILD INCH DATA: L <br />JURISDICTION: CITY OF EVERETT <br />CODES: 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) <br />2015 WASHINGTON STATE ENERGY CODE (WsECAdditional Permits Are Required <br />OCCUPANCY: R, 3(S NGLE FAMILY DETACHERES DENDC��W DENSITY) For This Project To Include' <br />LOT SIZE: 3,920 SOFT. <br />BUILDING AREA: FIRST FLOOR: 652 SOFT„ Plumbing ❑ Sprinkler <br />ATTACHED GARAGE 220 SOFT. ❑ Mechanical ❑ Fire Alarm <br />SHEETINDEX Electrical <br />SHEET I SCOPE OF WORK SUMMARY, SITE PLAN, VICINITY MAP, ASSESSOR'S <br />NO., LEGAL DESCRIPTION, SHEET INDEX AND NOTES <br />SHEET 2 FLOOR PLAN AND ROOF FRAMING PLAN 1 <br />SHEET 3 SECTIONS, CROSS-SECTION AND ROOF VENTILATION CALCULATIONS <br />STRUCTURAL NOTES: <br />CODE, <br />THE INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 EDITION AND THE 2015 INTERNATIONAL <br />EXISTING BUILDING CODE (IEBC), WITH THE STATE OF WASHINGTON AMENDMENTS. <br />LIVE LOADS: <br />ROOF SNOW LOAD 25 PSF <br />NAILS: <br />NAILING SHALL BE IN ACCORDANCE W/ FASTENING SCHEDULE TABLES 23-25 IN ICC-ES <br />EVALUATION REPORT ESR-1539 PREPARED FOR THE INTERNATIONAL STAPLE, NAIL AND <br />TOOL ASSOCIATION (ISANTA). ALL NAILS SHALL HAVE STANDARD SIZE ROUND HEADS <br />UNLESS NOTED OTHERWISE ON THE DRAWINGS. NAIL LENGTHS AND DIAMETERS SHALL BE <br />AS FOLLOWS: <br />10d 3" x 0.131" DIA. <br />10d COMMON 3" x 0.146" DIA, <br />ALL NAILS EXPOSED TO WEATHER OR IN CONTACT WITH PRESSURE TREATED WOOD <br />SHALL BE HOT -DIPPED GALVANIZED PER ASTM A153-CLASS D. <br />LIGHT GAUGE FRAMING CONNECTORS: <br />NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS AND OTHER <br />CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED <br />BY THE SIMPSON STRONG -TIE COMPANY, DUBLIN, CALIFORNIA. EQUIVALENT DEVICES BY <br />OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE [CC -ES APPROVAL <br />FOR EQUAL LOAD CAPACITIES. CONNECTORS SHALL BE FASTENED TO THE FRAMING <br />MEMBERS USING THE NUMBER AND TYPE OF FASTENERS CALLED FOR BY MANUFACTURER <br />HANGERS AND CLIPS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE <br />ZMAX/HDG GALVANIZED CONNECTORS. ALL HANGER FASTENERS USED WITH ZMAX/HDG <br />GALVANIZED CONNECTORS SHALL BE HOT -DIPPED GALVANIZED PER ASTM A153-CLASS <br />D OR SIDS, SCREWS WITH PROPRIETARY COATINGS, <br />STRUCTURAL LUMBER GRADES AND SHEATHING RATINGS: <br />ALL LUMBER SHALL BE GRADED IN ACCORDANCE WITH CURRENT WWPA STANDARD <br />GRADING RULES FOR WESTERN LUMBER. USE THE FOLLOWING SPECIES AND MINIMUM <br />GRADE: <br />STUDS d COLUMNS HEM -FIR 02 Fc=1300 PSI OR STUD GRADE Fc=800 PSI <br />WALL PLATES d SILLS HEM -FIR 02 Fb=850 PSI <br />JOISTS E RAFTERS HEM -FIR 01 Fb=915 PSI OR n Fb=850 PSI <br />ALL SHEATHING SHALL BE APA PERFORMANCE RATED PANELS. SHEATHING SHALL BE <br />PLYWOOD OR ORIENTED STRAND BOARD (OSB). BOND CLASSIFICATION SHALL BE <br />'EXPOSURE 1' WHERE PROTECTED FROM THE WEATHER. BOND CLASSIFICATION SHALL BE <br />'EXTERIOR' WHERE EXPOSED, SUCH AS EAVE AND SIDING APPLICATIONS. ALL ABUTTING <br />PANELS SHALL HAVE 116" GAP. <br />0 <br />0 <br />R <br />_m <br />� 0 <br />• 3 �j[�� -fir <br />O o U O Q <br />6 <br />rz <br />/� �• x 1 W <br />z <br />JU1 UJ <br />UJ <br />w � <br />O <br />z <br />UZ <br />z i-0 (L LU <br />d) <br />UJ (L d) Z <br />(L Lu <br />C V W <br />W z <br />0 <br />ototoAAA <br />lu <br />V � <br />z <br />W nn w <br />_Q !/- <br />lu T <br />Lu <br />V z <br />4 <br />Q a <br />Q Q Q <br />a b- <br />1 u`_ CA <br />7/9/2019 <br />19140 WD 01.dwg <br />ALL INFORMATION ON THIS DOCUMENT <br />IS THE EXCLUSIVE PROPERTY OF <br />PACIFIC ENCsINEERINCs TEC14NOLMES, .INC. <br />© COPYRIGHT 2019 <br />0 <br />W <br />Job No. 1-B140.00 <br />