GENERAL NOTES <br />1. Introduction <br />B.E.E. Consulting, LLC (BEE) has created building envelop e,Mncept design detaiis for the <br />Waterfront Place Apartments, The building envelope detail drawings are intimately related <br />to the materials specified in the project material specifications and building inspection. <br />Details provided by BEE are only for use on the Waterfront Place Apartments and are LID - <br />copyrighted, <br />Each sheet in this set of Building Envelope drawings, bearing the BEE Titleblock and Logo in <br />the upper right corner, was prepared by BEE and is accounted -for in, the drawing index on <br />the title page. in its original -form, this set was prepared for SeaLevel Proper -ties fora specific <br />project, <br />The act Of Submitting -for government approval of building permit, a set of drawings bearing <br />the BEE titleblock and logo, which has been altered in anyway by SeaLevel Properties, by any <br />third party, or for a project other than that which it was originally prepared by BEE without <br />the prior, written, consent of BEE shall constitute consent by SeaLevel Properties to defend, <br />indemnify, and hold harmless BEE from and against any and all claims, suits, demands, <br />liabilities, losses, and costs arising in whole or In part out of or in any way connected with the <br />use of the such altered drawings by SeaLevel Properties or any third party. <br />Such alterations shall include, but shall not be limited to, the addition or rernoval of <br />individual sheets, the modifications of any graphic or textual information contained within a <br />sheet prepared by BEE, The removal of this statement, and any construction inconsistent <br />with -that which has been shown by BEE in its original drawing set. <br />11. General <br />A. Water Penetration Resistance Field Testing <br />For all windows.. doors, and skylights a mock setup will be water intrusion tested in field -to <br />given parameters, Mock setup may, be created in situ or be free standing as determined by <br />BEE project engineer. <br />At least one (1) window of each operational -type will be tested to the Specified Field Test <br />Pressure specified below, in accordance with the Current version of ASTM E 1105. For <br />windows and doors such as aluminum, wood clad aluminum, vinyl, or fiberglass windows and <br />doors, Procedure 6 'cyclic) test will be used for 4 cycles each 5 minutes in duration, with a <br />pressure reduced to 0 psf for one minute between cycles. For storefront and curtain wall <br />assemblies, Procedure A (Uniform) test will be used for a single cycle of 15 minutes in <br />duration, The initial test will be inclusive of both Installation interface and window product. <br />In the case of failure (defined In ASTM 1105), the representative sample will be expanded to <br />five (5) specimens In order to obtain statistical confidence in remedial repairs If needed. In <br />the case of failure, the responsible party will be held financially liable for the cost of <br />retesting, and any related wall assembly or cladding deconstruction needed to obtain <br />Any ornissions or contrafflctions In these documents shall be called to the attention of BEE <br />prior to Submitting a bid, Bids received shall be considered to include all Items shown and/or <br />specified or scheduled for a complete project. The contractor shad note that the <br />waterproofing details do not always reflect the Architectural details and are intended to <br />supplement -the architectural details not replace them, <br />Installers are to be certified by manufacturer"s approved warranty requirements, <br />F. Material Warranty <br />Ali waterproofing material warranties shall be transferable to new building ownership within <br />the warranty's period. <br />G. Material Submittals/Substitutions <br />All material shall be submitted with location to be used physically or electronicaily to the <br />responsible BEE project manager, <br />H. Fasteners <br />All -Fasteners used through pressure treated material to be stainless steel, <br />Ill. ConstrucUon <br />Inspection <br />Building inspection shall be performed throughout the duration of construction. The <br />frequency of inspection is identified In the contract, Inspections will be performed on site. <br />Inspections will be documented and recorded as deemed necessary by the project manager. <br />Dry -in Requirements <br />The General Contractor (GC) shall provide quality assurance procedures, facHitate <br />inspections and coordinate testing and verification to maintain the materiai standards and <br />enveloping practices as specified herein, This shall also include periodically documenting the <br />moisture content by weight at a minimum of three (3) locations of framing, sheathing and <br />gypsum, Additionally, the -temperature and moisture content of concrete slabs shall be <br />monitored and periodically documented to comply with any relative waterproofing <br />installations that are to be conducted. Documented signs of excessive water or humidity are <br />exhibited by, but not limited to: <br />interior condensation on window. Warping, staining, or delamination of fiber cernent, <br />gypsum or wood based products (i.e. construction pre odUCt5that are absorptive). Organic <br />growth (mold, fungi, mildew), Water intrusionfleaks and or damage, <br />Roofs need to be Installed prior to construction drying and wet substrates/framing shall not <br />be directly covered with roofing or other finish materials. Permanently installed HVAC <br />equipment is not to be used for the purpose of construction drying. Any questions pertaining <br />passing results. This test specification supersedes AAMA Voluntary Specification for Field to the allowable moisture percentage of specific materials shall be referred to the most <br />Testing. applicable edition of the building code. <br />Regardless of AAMA deductions for field installed product, the mWrnurn Water Resistance <br />Field Test Pressure (during field test), as determined by the consultant, shall be: <br />8.0 psf for sliding doors <br />8.0 psf for storefronts <br />8 O psf for swing doors <br />8.0 psf for windows <br />The above referenced test pressures should be placed on the purchase order prior to <br />ordering the windows or doors. <br />Doors are to be installed and tested in a similar fashion as windows. <br />Louvers through the b0ding envelope should be designed In accordance with wind and rain <br />exposure conditions, <br />The minimum Wind & Water Resistance Pressure per manufacture shall be: <br />8.0 psf for louvers <br />C. SeWant Perf6rrnance Requirements <br />Ali sealants shall be validated and approved by the Sealant Waterproofing and Restoration <br />Institute (SWRI), <br />Sealant and Self Adhesive Membrane (.A.M.) combinations shall be sent to sealant <br />manufacturer for adhesion certification prior to construction. <br />All sealant dependent installations require adhesion -test per -formed on site by contractor. <br />Adhesion test logs shall be submitted to BEE for review. <br />D. LaboratoryTest Reports <br />All windows and doors should be pre -tested by the manufacturer to design conditions, <br />The associated test records shall be submitted to BEE. <br />E. Contractor Responsibility <br />It -,hall be the specific duty and responsibility of each -trade and supplier to examine all <br />project drawings, details and specifications, and to provide and fUrnish proper equipment, <br />hardware, fixtures, materials, etc., pertaining to their part of the work shown or Hsted in any <br />part of these documents. Quality control, adverse material reactions, and compliance to <br />industry standard workmanship are the responsibility of the contractor. Schedules are for <br />the convenience of the contractor to assist them in understanding and ,constructing the <br />project,, <br />BULDNG ENVELOPE <br />ENGNEERNG <br />B.E.E CONSULTING, LLD. <br />170 IN. DAYTON, SUITE 206 <br />EDMONDS, VVA 98020 <br />ph. (425) 672 3900 <br />fax (425) 712 8608 <br />THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENTS THAT IN MY PROFESS I ONALJUDGEOMENT <br />ARE APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCVV 64,55.005 THROUGH ROW 64.55 090, <br />0 1q, S T R U CT 10 N !SZE. T <br />i <br />P. E.: Jim C.Freeling Telman Gasanov <br />P.M.: Jim C.Freeling <br />Stephen Polledri <br />(D COPYR9GHT BEE CONSULTING <br />THESE DRAWINGS ARE FOR GENERAL ARRANGEMENT OF MATERIALS ONLY. <br />SITE CONDITIONS GOVERN. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. <br />SHEET: <br />SPECIFICATIONS <br />BEOOO <br />