My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
824 W CASINO RD BLDG B 2021-11-01
>
Address Records
>
W CASINO RD
>
824
>
BLDG B
>
824 W CASINO RD BLDG B 2021-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2021 1:55:28 PM
Creation date
11/1/2021 1:54:49 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
824
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12/11/2019 City of Everett Page <br /> 2:23:27PM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. M1911-009 Site Address 824 W CASINO RD B9&B10 <br /> Applied 11/4/2019 Applicant Lot <br /> Approved 11/4/2019 Owner CASINO-WESTMONT AFFORDABLE HOUSING Block <br /> Issued 11/4/2019 Contractor INTERSTATE RESTORATION WA LLC Tract <br /> Parent Permit No. B1906-027 Description REPLACE 4 EXHAUST,2 LAUNDRY VENTS FIRE DAMAGE R <br /> Notes SUBJECT TO FIELD INSPECTION.USING EXISTING ROOF VENTS.SEE ARCH DWGS FOR FIRE <br /> PROTECTION. <br /> Scheduled Completed Tvpe Inspector Result Remarks Inspector's Comments <br /> 11/5/2019 11/5/2019 MECH 04-ROUGH SDP CORRECTION (11/5/2019 2:39 PM SDP) <br /> IN Corrections: <br /> 1)Dryer ducts:penetrations of fire rated <br /> assemblies must be protected per IBC <br /> section 714. Dryer ducts shall be located <br /> outside the floor/ceiling or roof/ceiling <br /> assembly or be protected with a shaft. <br /> Remove the backdraft dampers installed in <br /> the duct. <br /> 2)The exhaust fans serving the upstairs <br /> apartment must be protected by a shaft or <br /> with a radiation damper on the exhaust fan. <br /> (the exhaust fans in the lower unit are ok) <br /> 3)Stove hood exhaust is required(see note <br /> 3 on page M.O. The min.6"duct must be <br /> in a shaft or run below the floor/ceilling <br /> assembly. <br /> 11/8/2019 11/8/2019 MECH 04-ROUGH DXW APPROVAL (11/8/2019 1:31 PM DXW) <br /> IN insp.will look at range hood duct at final. <br /> if duct is in soffit do not cover with out <br /> insp. <br /> 12/10/2019 12/10/2019 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> 12/10/2019 12/10/2019 MECH 06-FINAL DXW APPRVD-PERK eTRAKiT Inspection 12/9/2019 9:28 PM INTERSTATE <br /> Request RESTORATION WA LLC <br /> Contact Name:lance barkman <br /> Site Address:22342 68th Ave S <br /> Phone:4256330663 <br /> e-Mail: <br /> lbarkman@interstaterestoration.com <br /> (12/10/2019 3:32 PM DXW) <br /> as noted complete anti tip for range. <br /> INSPl2 R VSYSTEM <br />
The URL can be used to link to this page
Your browser does not support the video tag.