U <br /> c <br /> - <br /> ' T "� R -r iv, ,,,,, . ` '' . GENERAL PLUMBING NOTES: PLUMBING SPECIFICATIONS <br /> f• - $` <br /> ca I. it i i <br /> o i PART I-GENERAL <br /> `'- • <br /> 1. CONTRACTOR IS RESPONSIBLE FOR INSTALLING FIRE PROTECTION AND POTABLE <br /> ;:± ,• %x <br /> Q ` • - - - •• APPROXIMATE LOCATION ''` - '' -_' ' Y� WATER BACKFLOW PREVENTERS ACCORDING TO ALL APPLICABLE STATE AND 1.) FURNISH ALL LABOR,MATERIALS,EQUIPMENT AND TOOLS TO PERFORM WORK SHOWN, <br /> -oLOCAL CODES AND ORDINANCES. NOTED,SCHEDULED OR AS REQUIRED FOR A COMPLETE FINISHED INSTALLATION. <br /> ca OF WATER SERVICE ROOM A.) THE SCOPE OF WORK UNDER THE PLUMBING SHALL INCLUDE,BUT NOT <br /> o 4 <br /> 2. CONTRACTOR SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES, NECESSARILY BE LIMITED TO,THE FOLLOWING: <br /> I =_ . , „ 1.) POTABLE AND FIRE PROTECTION WATER PIPING <br /> INSPECTIONS,AND APPLICABLE TAXES. 2.) DRAINAGE AND VENT SYSTEMS <br /> aa) -- - <br /> � _. <br /> � I 11+__ OK vi. .# 7= ---Ti - B.) ALL MATERIALS AND EQUIPMENT SHALL BE NEW. <br /> E r- - I ` - •' - 3. PLUMBING CONTRACTOR TO COORDINATE INSTALLATION OF BACKFLOW C.) MATERIALS,PRODUCTS AND EQUIPMENT INCLUDING ALL COMPONENTS THEREOF, <br /> Y 'A i _ PREVENTERS WITH OWNER TO AVOID DISRUPTION OF NORMAL OPERATIONS. SHALL MEET REQUIREMENTS OF ASME,ASHRAE,NEMA,ASTM,AGA,ANSI,AND <br /> t ip _ _ OTHER RECOGNIZED STANDARDS. <br /> • c �"` .4 4.A" 4. DO ALL CUTTING AND PATCHING OF BUILDING MATERIALS AS REQUIRED FOR <br /> INSTALLATION OF FUNCTIONING AND COMPLETE BACKFLOW PREVENTION 2.) ALL WORK SHALL BE PERFORMED BY WORKMEN SKILLED IN THE PARTICULAR CRAFT <br /> ca <br /> j * t- • <br /> • r»it- EQUIPMENT. PATCHING OF BUILDING MATERIALS SHALL MATCH EXISTING FINISHES INVOLVED AND SHALL BE INSTALLED IN A NEAT,WORKMANLIKE MANNER IN KEEPING WITH <br /> AND CONSTRUCTION TO THE GREATEST EXTENT POSSIBLE. <br /> THE HIGHEST STANDARDS OF THE CRAFT. <br /> o x _ . <br /> "= 5. ALL NEW PIPING IS TO MATCH EXISTING PIPING TYPE UNLESS OTHERWISE NOTED. <br /> 3.) ALL WORK SHALL BE IN ACCORDANCE WITH UNIFORM PLUMBING CODES,NFPA,AND ALL <br /> 5 i . "'� APPLICABLE FEDERAL,STATE AND LOCAL CODES. WHEREVER THERE IS A CONFLICT,THE <br /> a) J MORE STRINGENT REQUIREMENT SHALL APPLY. <br /> - 6. PLUMBING CONTRACTOR IS ADVISED THAT ALL LOCATIONS ARE APPROXIMATE. <br /> •• ALTHOUGH DRAWINGS INDICATE PREFERRED LOCATION FOR NEW EQUIPMENT, 4.) CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTION <br /> u) TARGET STORE T0337 t 4 _ , ' P CONTRACTOR WILL NEED TO COORDINATE FINAL LOCATIONS OF EQUIPMENT CERTIFICATES. <br /> L . _ ,r I- - . ON-SITE AND/OR WITH THE OWNER WHERE REQUIRED. <br /> F -Ik 405 SE EVERETT MALL WAY o r 5.) CONTRACTOR SHALL COMPLY WITH THE RULES AND REGULATIONS OF THE LOCAL UTILITY <br /> ui cp . 1 EVERETT, WA 98208 1 7. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN WORK AND SHALL COMPANIES(WATER,SEWERS,ETC.). CHECK WITH EACH UTILITY COMPANY AND <br /> ✓ `. PROTECT ALL EXISTING WORK FROM DAMAGE.ANY DAMAGE TO EXISTING DETERMINE OR VERIFY THEIR REQUIREMENTS REGARDING INCOMING SERVICES. <br /> EQUIPMENT INCURRED BY THE PLUMBING CONTRACTOR IS TO BE REPLACED AT <br /> •. ` 't ,_� THE PLUMBING CONTRACTOR'S EXPENSE. 6.) FLOOR PLAN DRAWINGS PROVIDED TO THE CONTRACTOR ARE IN PART DIAGRAMMATIC, <br /> Q INTENDED TO CONVEY THE SCOPE OF WORK AND INDICATE THE GENERAL ARRANGEMENT <br /> -o i�, ,,.,e '-- 4:1 « •2 8. PLUMBING CONTRACTOR SHALL FAMILIARIZE HIMSELF ON-SITE WITH THE EXTENT OF EQUIPMENT. <br /> ca <br /> �� ' OF THE PROJECT AND MORE SPECIFICALLY TO NOTE WHERE ARCHITECTURAL OR <br /> L �i _ _ ` EXISTING EQUIPMENT DETAILS MAY AFFECT THE INSTALLATION OF THE NEW 7.) CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID FOR WORK TO FAMILIARIZE <br /> o �y HIMSELF WITH THE CONDITIONS WHICH WILL AFFECT HIS WORK. <br /> I tip `- ''`" - BACKFLOW PREVENTERS. <br /> a) _R. "• Al 8.) SUBMIT SHOP DRAWINGS FOR MAJOR EQUIPMENT TO ENGINEER FOR REVIEW. LIM <br /> - .�-• _ ` _ 9. THESE DRAWINGS ARE NECESSARILY DIAGRAMMATIC IN NATURE AND INDICATE SUBMITTALS SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS 7 <br /> -s . . NORTH DESIGN INTENT. NOT ALL FITTINGS,OFFSETS,VENTS, DRAINS, ETC.,ARE SHOWN. REVIEWED AND APPROVED THEM. 0U <br /> - .st ` • <br /> - ;•, " ;' -,;; OW THE CONTRACTOR SHALL INCLUDE ALL FITTINGS,OFFSETS, DRAINS,AND z Z <br /> 0 , <br /> _ ., - ACCESSORIES AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. 9.) CONTRACTOR SHALL LAY OUT HIS OWN WORK AND SHALL BE RESPONSIBLE FOR w <br /> _o DETERMINING THE EXACT LOCATIONS FOR EQUIPMENT AND ROUGH-INS AND THE EXACT W J <br /> Q ROUTING OF PIPING SO AS TO BEST FIT THE LAYOUT OF THE WORK. U < N. OU <br /> VICINITY MAP 10.) CONTRACTOR SHALL PROVIDE CUTTING IN THE EXISTING STRUCTURE,AS REQUIRED FOR O0 17 z <br /> ca <br /> -oTHE INSTALLATION OF WORK. CONTRACTOR TO PROVIDE PATCHING AND PAINTING TO w o u ix <br /> a NTS PLUMBING SYMBOL LIST MATCH EXISTING SURFACES. ^ z o O <br /> w ' <br /> O 11.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SCHEDULE AND COORDINATE WORK z ? J <br /> N SYMBOL DESCRIPTION WITH THE SCHEDULE OF THE OWNER SO AS TO PROGRESS THE WORK EXPEDITIOUSLY, >4 ct w LLj <br /> '� AND TO AVOID UNNECESSARY INTERRUPTION OF NORMAL OPERATIONS. O z 1 <br /> SEE ENLARGED VAULT DETAILS i w O • <br /> c, <br /> r _ _ _ _ _- - -0 PIPE DOWN 12.) PIPING AND DUCTWORK PASSING THROUGH ALL FIRE OR SMOKE RATED FLOORS,ROOFS, CU w I-1-1 ri- i <br /> WALLS,AND PARTITIONS SHALL BE PROVIDED WITH FIRESTOPPING. SPACE BETWEEN Et <br /> J Et <br /> aa) - �\�• WALL/FLOOR AND PIPING AND DUCTWORK SHALL BE SEALED WITH FIRE BARRIER MATERIAL Y <br /> REMOVE EXISTING © I 0 PIPE UP EQUIVALENT TO RATING OF WALUFLOOR. <br /> .' DOMESTIC - o <br /> o BACKFLOW I A IS RECONNECT TO II Y- STRAINER 13.) CONTRACTOR SHALL DO ALL EXCAVATING NECESSARY FOR UNDERGROUND PIPING,AND N w <br /> PREVENTER 8" FIRE PROTECTION EXISTING DOMESTIC EQUIPMENT AS REQUIRED AND SHALL BACKFILL TRENCHES AND EXCAVATIONS AFTER OO <br /> WATER SUPPLY ,k WORK HAS BEEN INSPECTED. EXCAVATE TO DEPTH REQUIRED FOR PROPER OPERATION. ' N- <br /> WATER SHUT-OFF VALVE SHORE AND BRACE EXCAVATION AND PERFORM TEMPORARY WORK AS REQUIRED TO <br /> 2.5" DOMESTIC - - SEE ENLARGED FIREAXE PROTECT ADJACENT AREA TO THE EXCAVATION AND FOR SAFE WORKING CONDITIONS. <br /> ibi <br /> E WATER SUPPLY s PROTECTION RISER DETAIL <br /> o O � CH ECK VALVE 14.) CONTRACTOR SHALL COORDINATE THE REQUIREMENTS FOR TEMPORARY WATER <br /> -o <br /> _ _ SERVICES WITH THE OWNER. ANY TEMPORARY SERVICES PROVIDED SHALL BE REMOVED <br /> u UPON COMPLETION. <br /> 1E I n 1 I PRESSURE REDUCING VALVE <br /> g 0 O O O O I 15.) CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES <br /> o AND,UPON COMPLETION,SHALL TURN OVER TO THE ENGINEER A"RECORD"SET OF PRINTS <br /> a girAr �'��� �- I REINSTALLDOMESTICWATEREXISTING -wI- ACTUATED VALVE SHOWING THESE CHANGES. <br /> -- -- <br /> �' A PRESSURE REDUCING 16.) MATERIALS,EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FORA PERIOD OF ONE <br /> a� ASSEMBLY ik BACKFLOW PREVENTER (TYP.) (1)YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD <br /> o_ SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. <br /> 2 <br /> I I El <br /> - ] BLIND CAP 17.) PRIOR TO ACCEPTANCE OF THE INSTALLATION,THE CONTRACTOR SHALL DEMONSTRATE <br /> j <br /> J L v ' TO THE OWNER,OR HIS DESIGNATED REPRESENTATIVES,ALL ESSENTIAL FEATURES AND <br /> cREFER TO ENLARGED EQUIPMENT TAG FUNCTIONS OF ALL SYSTEMS INSTALLED,AND SHALL INSTRUCT THE OWNER IN THE <br /> '� s DOMESTIC WATER RISER e PROPER OPERATION AND MAINTENANCE OF SUCH SYSTEMS. <br /> o I__lull <br /> a) ELEVATION DETAIL <br /> u) REMOVE EXISTING DOMESTIC ILV 18.) SYSTEMS,AT TIME OF COMPLETION,SHALL BE COMPLETE,EFFICIENTLY OPERATING, <br /> o 7T-sixiBT,Exi,i,:rm_,TciiONNG CONNECT TO EXISTING NON HAZARDOUS AND READY FOR NORMAL USE BY THE OWNER. WHEN ALL THE WORK IS <br /> II COMPLETE THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL MATERIAL AND EQUIPMENT <br /> . BACKFLOW PREVENTER SITE PLAN O PRESSURE GAUGE INSTALLED AS A PART OF THIS CONTRACT AND LEAVE ALL EQUIPMENT AND MATERIAL IN <br /> 2 PREPARE REMAINING PIPING W COONTA U AHE SITE <br /> FOR RECONNECTION N.T.S. <br /> DEBRISNE ,NE Dx!CT EI Os Ns.MTHEATERIA CL ANDR EQUIPMENT <br /> SHALL LEFT <br /> CLEAN DUPRINGND THEREMOVE PROGRESSFROM T OF THIS ALL <br /> o ' //////// ITEM TO BE DEMO'D CONTRACT AT JOB COMPLETION. <br /> L. V <br /> E / A PART IA-PRODUCTS-PLUMBING <br /> N BFP - -- -- BURIED PIPE 1.) PIPING: PROVIDE AND INSTALL ALL BACKFLOW PREVENTORS,VALVES,UNIONS,SLEEVES, <br /> ROUTE DRAIN TO 2 STRAINERS,ESCUTCHEONS,IDENTIFICATION,AND BY-PASS PIPING AS REQUIRED FOR A <br /> NEAREST FLOOR DRAIN COMPLETE SYSTEM AND AS REQUIRED BY ALL APPLICABLE CODES. <br /> oABOVE GROUND PIPING <br /> L A OR THROUGH EXTERIOR 2.) NEW PIPING IS TO MATCH THE EXISTING PIPING UNLESS OTHERWISE NOTED OR <br /> N O , WALL TO GRADE. / METER ACCORDING TO THE FOLLOWING PIPE SCHEDULES: <br /> o - © A.) ABOVE GRADE COLD WATER PIPING SHALL BE TYPE"L"HARD TEMPER COPPER <br /> v CONNECT NEW BACKFLOW WATER TUBING,WITH 95-5 TIN-ANTIMONY SOLDERED JOINTS. <br /> FLOOR 1 2 i '�PREVENTER TO EXISTING B.) FIRE PROTECTION PIPING SHALL BE SCHEDULE 40 BLACK SEAMLESS STEEL <br /> O BACKFLOW PREVENTER (ALT. NOTATION) PIPE UP TO 8"(SCHEDULE 30 ABOVE 8")WITH CLASS 125 CAST IRON THREADED <br /> I_ ca WATER SUPPLY LINE <br /> N o FITTINGS OR GROOVED PIPE COUPLING TYPE. <br /> N `\ '` \� ,\ \ \\1111111111111M \ ,' \ IIIINIZINIP 3.) PLUMBING AND FIRE PROTECTION EQUIPMENT SHALL BE FURNISHED AND INSTALLED Z <br /> Q /\� •\ `\ �\ /\ \ .\ .\ COMPLETE WITH SUPPLIES,VALVES,TRIM,AND PIPING AS REQUIRED FOR A COMPLETE AND <br /> O FUNCTIONING SYSTEM. IN GENERAL,THE FOLLOWING QUALITY STANDARDS SHALL APPLY: <br /> Z `0 Q <br /> U <br /> Q TYPE MANUFACTURER <br /> U) <br /> A A <br /> -0 a) POTABLE WATER BACKFLOW PREVENTER-RPZ TYPE ZURN WILKINS <br /> Om <br /> QFIRE PROTECTION BACKFLOW PREVENTERS-DOUBLE CHECK TYPE ZURN WILKINS <br /> 0 <br /> J >, 4.) FIRE PROTECTION BACKFLOW PREVENTERS SHALL COMPLY WITH REQUIREMENTS OF <br /> ANSI/NFPA 13 FOR INSTALLATION OF FIRE SPRINKLER PIPING PRODUCTS. INSTALL IN (19 <br /> 0 <br /> Ur ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTION,AND IN ACCORDANCE WITH <br /> DOMESTIC WATER RISER DEMOLITION DOMESTIC WATER RISER RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT FIRE SPRINKLER BACKFLOW <br /> CO a) ELEVATION PLAN ELEVATION PLAN Z 7:3 Z <br /> PREVENTER COMPLIES WITH REGULATORY REQUIREMENTS AND SERVES INTENDED - <br /> PURPOSES. <br /> D . N.T.S. N.T.S. COu) <br /> 0- .0 BACKFLOW PREVENTER SCHEDULE Z2 <br /> _ U) <br /> 0 TAG MFGR&MODEL TYPE SIZE PD(PSI) COMMENTS O <br /> in -o -o -o _0 -o -o -o M <br /> o -o I- <br /> N G ;d � � BFP-1 ZURN WILKINS 350 ADA DOUBLE CHECK DETECTOR ASSEMBLY 8" 2 1 <br /> _c E 0 -0 .0 • d -0 -@ L`J INSTALL NEW 8" FIRE 0 <br /> O 1 1 REMOVE EXISTING 8" FIRE BFP-2 ZURN WILKINS 475V REDUCED PRESSURE PRINCIPLE 2.5" 14.5 2 <br /> PROTECTION BACKFLOWD 0. <br /> co . PROTECTION BACKFLOW PREVENTER. CONNECT TO NOTES: <br /> 11 <br /> PREVENTER •..9 EXISTING 8" PIPING. 1. PRESSURE DROP RATED AT 1000 GPM FLOW. H <br /> p X X X 2. PRESSURE DROP RATED AT 225 GPM FLOW. <br /> Q a <br /> a) • <br /> . . ._, ._, „., ... .,._ <br /> ° z H <br /> cy) . <br /> . _a . . ) , o J <br /> N ' ,•' • �� / PREPARE REMAINING PIPE '• ' U w <br /> p a <br /> FOR RECONNECTION (TYP.) <br /> N <br /> 2 <br /> --- 2 Q._ <br /> • <br /> Q d 1-17W <br /> d X-\-\-X LL <br /> co • <br /> C' / O O <br /> a' .44. <br /> v' C / \-s FLOOR a 0 0 <br /> N , . d �/ a <br /> ,� FLOOR / //� / CO a p Ill <br /> • <br /> ca .a . G v d.. d v <br /> %\ Q v C /\ • v. • d • • . . °. d 'A d A. <br /> O0. <br /> • <br /> • r • v7. d t1 g <br /> MQ /• d 4. • d :v v • °° d idd a / ,%\X a� �% '/ '/ y/ '/\\ d w a '\\/` X \ Z W <br /> M 0 \\,\\7. ��%�\, \\;\\;��.\\ -\x<, \-/\ \,, • ��/���. •���\��,���. • ix W a <br /> of o \ /\/ ._.o' ' / i./ ._.c ' H <br /> \<BF <br /> P <br /> wiv. <br /> \,. . 1 <br /> %,�,j z M a w <br /> 5 g i ./ el <br /> w \ \ re <br /> -ff �_ O w <br /> �I E FIRE PROTECTION RISER DEMOLITION ELEVATION PLAN FIRE PROTECTION RISER ELEVATION PLAN J ~ w <br /> w <br /> U <br /> w SHEET NUMBER <br /> N.T.S. N.T.S. <br /> Y P1 .0 <br />