Laserfiche WebLink
Project Quantity Item# <br /> Model Specified: CSI Section 11400 <br /> Specifications <br /> Construction,Hardware and Insulation Heating System <br /> Cabinet exterior front,one piece sides,louver assembly and doors are constructed A low watt density,serpentine style,heater is employed for the generation of electric <br /> of 20 gauge stainless steel with #4 finish. Cabinet interior and door liners are , heat. Low velocity air is forced across its large surface area to efficiently move heat <br /> constructed of stainless steel(anodized aluminum in the A-Series).The exterior cabi- radiating away from these through a down-air distribution duct,where it is then evenly <br /> net top,back and bottom are constructed of heavy gauge aluminized steel.The interior distributed throughout the cabinet,assuring the proper holding environment for hot <br /> floor and exterior bottom are constructed of stainless steel and insulated with%;'of food product,without drying.A vent,located at the top of the cabinet,is included <br /> resilient cork.A readily attachable stainless steel ramp is provided. for positive humidity control. <br /> Doors are equipped with a heavy-duty,extruded wiper gasket for sealing to bottom Controller <br /> ramp, removable plug cylinder locks and guaranteed for life cam-lift, gravity ac- The easy to use water resistant INTELA-TRAUL®microprocessor control system <br /> tion,self-closing metal,glide hinges with stay open feature at 120 degrees.Hinges is supplied standard.RS485 data port enables data communications for remote <br /> include a concealed switch to automatically activate the interior incandescent monitoring such as NAFEM Data Protocol,E-Control Systems®and others.It includes <br /> lighting.Guaranteed for life,work flow door handles are mounted horizontally over a 3-Digit LED Display and Fahrenheit or Celsius Temperature Scale Display Capabil- <br /> recess in door which limits protrusion from door face into aisleways. Doors have <br /> ity,In addition it includes audio/visual alarms for:Hi/Lo Cabinet Temperature,Door <br /> seamless,polished metal corners. Open,Clean Condenser,Evaporator Coil and Discharge Line Sensor Failures,and <br /> Gasket profile and Santoprene®material simplify cleaning and increase overall Power Supply Interruption. <br /> gasket life. Interior <br /> Both the cabinet and door(s)are insulated with an average of 2"thick high density, Readily removable,interior-mounted,stainless steel guides for rack are provided <br /> non-CFC,foamed in place polyurethane. for protection. Maximum rack size with wheels inboard of frame is 27"wide by 29" <br /> deep by 66"high. Racks supplied by others. <br /> DIMENSIONAL DATA RIAIH132L R/AIH232L RIAIH332L Warranties <br /> Net capacity cu.ft. 36.0(1020 cu I) 74.3(2105 cu I) 117.5(3329 cu I) A three year parts and labor warranty is provided standard. <br /> Length-overall in. 351A(90.2 cm) 68(172.7 cm) 100% (255.3 cm) <br /> Depth-overall in. 359/16(90.3 cm) 359/16(90.3 cm) 359/16(90.3 cm) <br /> Depth-over body in. 32(81.3 cm) 32(81.3 cm) 32(81.3 cm) s , <br /> Depth-door open 90°in. 6311A(160.7 cm) 631/+(160.7 cm) 63''A(160.7 cm) I I ) I I <br /> Clear door width in.' 271A(68.8 cm) 27''A(68.8 cm) 2711A(68.8 cm) <br /> Clear door height in. 665/6(168.4 cm) 665/16(168.4 cm) 665A6(168.4 cm) <br /> Height-overall 8311A(211.5 cm) 831/4(211.5 cm) 8311A(211.5 cm) I <br /> ( ) I �r 1,-E0* ) <br /> RIH Net Wt.lbs.2 350(159 kg) 580(263 kg) 1075(488 kg) <br /> AIH Net Wt.lbs.2 280(127 kg) 480(218 kg) 1000(454 kg) <br /> Rack Capacity 1 2 3 <br /> ELECTRICAL DATA I [ ) [ ) ) <br /> Voltage 208/115/60/1 208/115/60/1 208/115/60/1 Elevation- Elevation- Elevation- <br /> Feed wires with Ground 4 4 4 R/AIH132L R/AIH232L R/AIH232L <br /> Wattage @ 208V 1500 3000 3000 <br /> Full load amperes©208V 7.8 15.5 15.5 3s)[90.2 ] <br /> w)[77Scm] 1---ea <br /> [,72."---I <br /> SHIPPING DATA E _ [f6om i <br /> Length-crated in. 41(104 cm) 73(160 cm) 106(269 cm) 7� <br /> Depth-crated in. 44(112 cm) 44(112 cm) 44(112 cm) 271b[�7cmi T <br /> « - 2 PLCS.71P. s <br /> Height-crated in. 901A(230 cm) 901(230 cm) 90%(230 cm) s - - . <br /> Volume-crated cu.ft. 95(2691 cu I) 168(4759 cu I) 250(7082 cu I) e <br /> 17l[68.67y <br /> ,`NOTES •.� <br /> NOTE:Figures in parentheses reflect metric equivalents. - <br /> .._ .. <br /> 1= Please note that the available cabinet width narrows for 6"from the top of the door frame to 25-7/8"in "-- <br /> order to allow for the heater fans. Plan-R/AIH132L <br /> 2= For shipping weights and dimensions please refer to form TR35875. Plan-R/AIH232L <br /> fool[265.3tm1 I <br /> 1951[242.etml JJ <br /> n Ir-1-27 [667cmi 3 PLC9.ttP. r32[81.3c9]-1 <br /> 2 <br /> fit) EquippedWith One NEMA L14-20P Plug <br /> (one section models only) Plan-R/AIH332L 4771 <br /> wl <br /> NOTE:When ordering please specify:Voltage,Hinging,Door Size,Options and any additional warranties. <br /> jr <br /> I�-394[99.7cmi--1 <br /> Continued product development may necessitate specification changes without notice. Section-All Models <br /> Part No.TR35792(REVISED 10-13-14) <br /> TRAULSEN <br /> 4401 BLUE MOUND RD. FT.WORTH,TX 76106 <br /> PHONE 1 (800)825-8220 FAX-MKTG.1 (817)624-4302 • <br /> Website:www.traulsen.com <br />