Laserfiche WebLink
.se!aphen Dorsey AIA <br /> 134-23rd St.8UI <br /> Puyallup,WA 9A311 <br /> Tel:(253,W45-5IO6 <br /> Member American <br /> UGHTING NOTES: Wamte of Architects <br /> PROVIDE MEANS OF EGRESS ILLUMINATION PER SHEET A2.4 EMERGENCY UGHTING PLAN. <br /> PROVIDE AN AVERAGE 1 FOOT CANDLE MIN.AND 0.1 FOOT CANDLE AT ANY POINT.AT <br /> WALKING SURFACE.PROVIDE BATTERY BACKUP FOR 90 MIN.OF USE.AT END OF 90 MIN.USE <br /> UGHT OUTPUT MUST BE AT I FAST 60%OF INITIAL REQUIRED OUTPUT.DO NOT EXCEED 40:1 <br /> MAX.ILLUMINATION UNIFORMITY RATIO. <br /> PROVIDE FIRE ALARM SYSTEM PER LOCAL CODES.SUBCONTRACTORS TO SUBMIT SHOP <br /> DRAWINGS TO ARCHITECT AND TO PIERCE COUNTY FOR MECHANICAL AND ELECTRICAL <br /> PERMITS. <br /> PROVIDE OCCUPANCY SENSOR LIGHTING SWITCHES PER PLAN,SET TO 30 MINUTES.EXTERIOR <br /> LIGHTING SHALL BE CONTROLLED BY PHOTO CELL.UGHTING CONTROLS SHALL BE TESTED <br /> TO ENSURE THEY ARE FULLY FUNCTIONAL PER WASHINGTON STATE ENERGY CODE <br /> STANDARDS. <br /> DAYLIGHT ZONE NOTE <br /> PROVIDE DAYLIGHTING CONTROLS DEVICES CAPABLE OF AUTOMATICALLY REDUCING THE <br /> UGHTING POWER IN RESPONSE TO AVAILABLE DAYLIGHT BY CONTINUOUS DIMMING USING <br /> DIMMING BALLASTS AND DAYLIGHT-SENSING AUTOMATIC CONTROLS THAT ARE CAPABLE OF <br /> REDUCING THE POWER OF GENERAL LIGHTING IN THE DAYLIT ZONE CONTINUOUSLY TO LESS <br /> THAN 20 PERCENT OF RATED POWER AT MAXIMUM LIGHT OUTPUT. <br /> 60'-7 <br /> / LFACF <br /> 6519 REGISTER a, <br /> IAR CT <br /> \ rSECONDARY ZOVE DAY LIGHT 2QVE *� I /��Yu/'i, �, <br /> C) 77 S.F. 86 S.F. ." 111100 �u�.'.® ..I T- .' <br /> C_� <br /> e'0`AFF <br /> 'EXIST.GWB CEILING O 6 7 1 <br /> EMERGENCY I C) •r 10 <br /> Oz <br /> I <br /> .. f <br /> L - J <br /> • <br /> O O NEW A.C.T CE�NO +114' <br /> 8 <br /> Q <br /> FURR.70VIN v O _0 <br /> HEADER WALL , <br /> ( IVl(\\ _ A DATE DESCRIPTION <br /> 15 9'-O'A.F.F. <br /> ' A6.2TYP eNEW A.OT.CEILING 1CLG:1 '4 CLG.-2 }) I 1 Typ 3 <br /> i���/�I� I��I 9041D I I 0 Q <br /> V V IV/�VI 13 <br /> 20 A <br /> DA <br /> SECON DAR TONE r G I <br /> V L r+ti ZONE A <br /> 65 S.F. 100S.F +114 <br /> Q V • •-J' 18 A <br /> i-THIN-BRICK FINISH/ A <br /> NOTE: ON THIS WALL CLG.GRID <br /> 1.SEE MECHANICAL/ELECTRICAL SHTS.FOR LOCATION STARTING POINT <br /> OF SUPPLY/RETURN AIR REGISTERS AND LIGHTS AND <br /> NOTIFY PH CONSTRUCTION MGR.IF CONFLICTS OCCUR NOTE GRID STARTING DIMENSION MAY VARY CONTRACT DATE'. <br /> WITH THIS PLAN. DEPENDING UPON ACTUAL SITE CONDITIONS. CD BUILDING TYPE DELCO LITE <br /> 2.SEE FIRE SPRINKLER PLAN FOR LOCATION OF NOTIFY PH CONST.MGR.IF THIS OCCURS,PRIOR <br /> SPRINKLER HEADS AND NOTIFY PH CONST.MGR.IF TO INSTALLATION.(1YP). PLAN VERSION. <br /> CONFLICTS OCCUR WITH OTHER FIXTURES. 'V SITE NUMBER: TBD <br /> STORE NUMBER: TBD <br /> REFLECTED CEILING PLAN 1/4"=1'0' A PIZZA HUT <br /> 10121 EVERGREEN WAY,SUITE#23 <br /> Everett,WA.98204 <br /> 1. ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL,STATE AND LOCAL BUILDING t)INSTALL NEW 2k4'A.C.T.CEILING SYSTEM,AT+9'-0"A.F.F.AT KITCHEN.INSTALL NEW 2'X2' 12 3-MINI-PENDANT UGHTS(6W T-30 EA.,L-540#E52800540)TRACK MOUNTED&CENTERED <br /> CODES,REGULATIONS,ORDINANCES AND STANDARDS. ACT.SYSTEM AT 9'-6'AT LOBBY.SEE SHT.A1.0 FOR CLG.TILE MATERIAL CHANGE AT OVER CUSTOMER COUNTER.BLACK TRACK(L519#E52800519) <br /> KITCHEN AREA CEILING SYSTEM WILL COMPLY WITH ASTM C635&C636,ASCE 7-05&CISCA. 13 "BLACK'TRACK LIGHT FIXTURE (L-416#E52BD1026)WITH LED LAMPS(20W.EAjW1TH <br /> 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL BUILDING DIMENSIONS AND PER IBC 503.9 AND 808.1. , . <br /> /' .. <br /> PRIOR TO BEGINNING CONSTRUCTION.IMMEDIATELY NOTIFY OWNERS REPRESENTATIVE OF ANY CONFLICTS BLACK 6'TRACK L-519. <br /> BETWEEN LIGHT FIXTURES AND CEILING SYSTEM,DUCTS,HVAC EQUIPMENT,OR STRUCTURE AND ANY VARIANCE ®NEW 2X4'FLUSH LED LIGHT FIXTURE(30W MAX.)AND NEW EXHAUST FAN AT TOILET. O ' P�t' <br /> OR DISCREPANCY AFFECTING THE NEW CONSTRUCTION,PRIOR TO PROCEEDING WITH ANY WORK. LIGHT TO BE SWITCHED BY OCCUPANCY SENSOR SWITCH. 14 6'DOWN UGHT,WITH LED LAMP(12 W EA),PER PH STNDS.,ITEM#0 0 3 9 5-01 7/CT6FB/RC6-12W. 7, <br /> 3O SELF-ILLUMINATED'EXIT.SIGNS SUSPENDED FROM CEILING OR MOUNTED ON ADJACENT WALL. <br /> 3. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCES FOR BY UTHONIA,OR EQUAL.RE-USE EXIST.FIXTURE IF POSSIBLE. 15 NEW EMERGENCY WALL MID.LIGHT. DELCO LITE <br /> FIXTURES,DUCTS,PIPING,AND CEILING SUPENSION SYSTEM AS NECESSARY TO MAINTAIN THE FINISHED ®NEW 2k4'LED TROFFER LIGHT FIXTURE(SOW EA.),BV'E-CONIXJGHT'.FIXTURES SUPPLIED -i rr�� <br /> CEILING HEIGHTS INDICATED ON THE DRAWING. AND INSTALLED BY ELECTRICAL SUB-CONTRACTOR. EMERGENCY LED TROFFER LIGHT FIXTURE,PER CODE LOCATIONS.SEE ELECT.PLANS. OO 1.OJ.00 <br /> i6 <br /> 4. LIGHT FIXTURES,NEW SPRINKLERS,AND OTHER CEILING ELEMENTS SHALL BE CENTERED IN THE CEILING SO NEW WATER HEATER VENT AND MAKE-UP AIR.PER MECH.OWGS. CD SUPPLY OR RETURN HVAC REGISTER.SEE MECH.PLANS FOR FINAL LOCATION. <br /> TILES U.N.O. <br /> ALH5.INSTALL NEW LIGHT FIXTURES18 WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER,LENS,BAFFLE,ETC ©W IN COOLER/FZR.BELOW.(2)LED LIGHTS BY MANUFACTURER 20W EA.MAX. PROVIDE 20 AMP CIRCUIT&ELECT.DUPLEX OUTLET AT CEILING TILE,(1)PER EVERY 10 L.F. REFLECTED <br /> TO AVOID SOILING OF DAMAGE.ALL LAMPS SHALL BE NEW AT PROJECT COMPLETION. Q PIZZA OVEN HOOD OF TENANT FRONTAGE,FOR FUTURE LED SIGNS.OUTLET COVERS TO BE'BLACK'. CEILING <br /> 6. ALL EXIT AND EGRESS LIGHTING LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTORS ()FRYER HOOD <br /> FIELD DETERMINATIONS. Q NOT USED PLAN <br /> 7. TOTAL CONNECTED INTERIOR LIGHTING POWER IS 966 WATTS. <br /> CD INSTALL 120V 15AMP RECEPTACLE ABOVE CLG.AND SWITCHED FROM B.O.H.GANGED <br /> LIGHT SWITCHES.THIS OUTLET WILL CONTROL THE DRIVER DOOR ELECTRONIC STRIKE. .3 Al <br /> 11 319 MTL.STUDS(o 24"O.C.WITH EE GWB ON KITCHEN SIDE FROM TOP OF COOLER <br /> TO 6'ABOVE SUSP.CLG. <br /> RELFECTED CEILING PLAN GENARAL NOTES C KEY NOTES B PLOT DATE: 7-17-19 <br />