• <br /> •Bruce S. MacVeigh, P.E. <br /> Civil Engineer/Small Site Geotechnic D Ecipv <br /> 14245 59th Ave. S. <br /> Tukwila, WA 98168 OCT a 2019 <br /> Cell Ph: 206-571-8794 <br /> CITY OF EVERETT <br /> Permit Services <br /> October 11, 2019 (Revision) <br /> Subject: Roof-Mounted Unit and Hood Evaluation, Pizza Hut, 10121 <br /> Evergreen Way, Suite 23, Everett, WA 98204 <br /> General. <br /> The existing building will receive new/upgraded roof-mounted restaurant <br /> related units and new interior kitchen hoods. Also, one roof-mounted <br /> HVAC unit will be replaced at a new location (old one removed) and a new <br /> one installed with similar installation. It is a one-story tenant unit in an <br /> existing building. The layout of the existing roof has been verified by field <br /> measurement. Weights of units are per manufacturer. Documentation is <br /> attached. <br /> Comments/Evaluation Results. <br /> 1. The tenant space is 21' 8"wide and 60 feet long. A major glulam beam <br /> crosses the space 20 feet to the front of the rear wall. Running front to <br /> back are 2" x 4" (Paralam LVL) by 34.5" high wood roof trusses at 4 foot <br /> spacing. <br /> Note the glulam is a measured 6.75"wide by 31" deep, with a length of 40 <br /> feet, with a field verified column about 1.5 feet inside the tenant space <br /> near the left side. It continues its 40 foot length to the right beyond the <br /> right side tenant space wall. It is evaluated for both the replaced and <br /> added HVAC units, for their more or less direct load bearing on the beam. <br /> All new kitchen related roof-mounted units are evaluated. An existing <br /> smaller HVAC unit on the same beam for the tenant space to the right is <br /> included in the major beam evaluation. The beam is within capacity with <br /> the new unit installation. <br /> 2. Per attached calculations the 34.5" high roof trusses in the front 40 feet <br /> of the building have no additional moment capacity beyond existing basic <br /> roof loading. The trusses are open lattice 2.0 Paralam LVL (Truss Chord <br /> rated) top and bottom chord and cannot be reinforced to provide additional <br /> moment capacity. The solution is to block beneath the trusses with mid- <br /> span cross-beams with posts in the new building internal front-to-back wall <br /> and side walls. The solid post blocking will reduce the effective span for <br /> the trusses from 40 feet down to about 28 foot maximum span. With the <br /> added post and cross beam blocking under affected trusses (assumed all <br /> trusses), the two new Exhaust Fans#1 and #2 may be installed without <br /> otherwise altering the roof structure. Similarly, the new Makeup Air(MUA) <br /> may be safely installed. ` I L\ <br />