Laserfiche WebLink
e Permit#: B2102-004 <br /> Site Address: 2408 39TH ST <br /> IIII31: III <br /> Owner: SHEELER JACK <br /> t ' ll� Tenant: T-MOBILE <br /> F ' " Mobi1e ' " ' <br /> �App.Date: 2/3/2021 <br /> I"ul N x ,Proposed Use: COMMERCIALALTERATIONS <br /> Card y Description: REMOVE/REPLACE ANTENNAS AND OTHER <br /> ►L> Z. <br /> FIXTURES <br /> T-MOBILE SITE NUMBER: SE01513A BUSINESS UNIT #: 815285 the m ,a-l�1 <br /> 2408 39TH ST Date <br /> T-MOBILE SITE NAME: SHEELER/EVERETT SITE ADDRESS: EVERETT,WA98201 z Reviewed By- <br /> T-MOBILE PROJECT: ANCHOR COUNTY: SNOHOMISH C, ` c,� <br /> Office Set Job Site Set Fire/Planning Set <br /> SE01513A ANCHOR_SHEELER/EVERETT_FCD_T-MOBILE_01/21/2021 SITE TYPE: MONOPOLE Ew,` ' <br /> TOWER HEIGHT: 130'-0" I G- <br /> SITE INFORMATION DRAWING INDEX LOCATION MAP GPD GROUP <br /> SHEET# SHEET DESCRIPTION �r .a L Professional Co77:ration <br /> CROWN CASTLE USA INC. LOWET T F LC`i,V i v i i ti sm M.m Streel <br /> SITE NAME: T-1 TITLE SHEET DEVELOP"'=RF�-1�--I,T ,OH4431133Bs�z.zFol . H*MI <br /> SITE ADDRESS: 2408 39TH ST T-2 GENERAL NOTES I�, <br /> EVERETT,WA 98201 T-3 GENERAL NOTES BY /"'► <br /> COUNTY: SNOHOMISH C-1.1 OVERALL SITE PLAN <br /> IA <br /> MAP/PARCEL#: 00576003200011 DAT17 E_ 2 • �'• T-MOBILE SITE NUMBER: <br /> AREA OF CONSTRUCTION: EXISTING C-1.2 SITE PLAN ' <br /> C-1.3 EXISTING&FINAL EQUIPMENT PLANS SE01513A <br /> LATITUDE:ONITU4 22°11' SITE LOCATION <br /> LONGITUDE: -Izz"11'44.25" C-2.1 EXISTING&FINAL ET FVATIONS BU#: 815285 <br /> LAT/LONG TYPE: NAD83 C-2.2 ANTENNA SCHEDULES&PLANS <br /> GROUND ELEVATION: 56 FT.(PER GOOGLE EARTH) LOWELL <br /> CURRENT ZONING: I Il C-3 EXISTING&FINAL PLUMBING DIAGRAMS <br /> JURISDICTION: CITY OF EVERETT C-4 EQUIPMENT SPECS royal only applies to <br /> JURISDOCCUPINCY CTION: <br /> CLASSIFICATION: U C-5 EQUIPMENT SPECS This app erformed under 2408 39TH ST <br /> TYPE OF CONSTRUCTION: IIB C-6 EQUIPMENT SPECS the work b�Pl P .O�� EVERETT,WA 98201 <br /> A.D.A.COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR C 7 EQUIPMENT SPECS Permit # <br /> HUMAN HABITATION and does not recognize any EXISTING 130' 0"MONOPOLE <br /> PROPERTY OWNER SHEELER JACK C-8 CABINET SPECS <br /> 8919EASTVIEWAVE C-9 CABINET SPECS existing structure that may not <br /> meet Zoning <br /> EVERETT,WA 98208 C-10 CABINET SPECS GPD JOB NUMBER:2021724.71.815285.01 <br /> TOWER OWNER CROWN CASTLE <br /> 2000 CORPORATE DRIVE C-11 BATTERY DETAILS,CABINET INTERNAL&TECH LIGHT DETAIL <br /> NO SCALE ISSUED FOR: <br /> CANONSBURG,PA 15317 E-1 F.T.FCTRICAL PLAN AND ONE LINE DIAGRAM <br /> DRIVING DIRECTIONS FROM PAINE FIELD(3220 100TH ST SW,EVERETT,WA 98204): REV DATE DRWN DESCRIPTION DES./QA <br /> CARRIER/APPLICANT: T-MOBILE E-2 PANEL SCHEDULES <br /> 19807 NORTH CREEK PKWY N 0 01/21/2021 AJAI FINAL CJM <br /> E-3 WIRING DIAGRAMS GET ON WA-526 E IN EVERETT.HEAD EAST ON 100TH ST SW.TURN LEFT ONTO AIRPORT RD.USE THE RIGHT 2 LANES TO MERGE ONTO WA-526 E <br /> BOTHELL,WA 98011 VIA THE RAMP TO EVERETT.CONTINUE ON WA-526 E.TAKE 1-5 N TO 41ST ST.TAKE EXIT 192 FROM I-5 N.MERGE ONTO WA-526 E.USE THE LEFT <br /> ELECTRIC PROVIDER SNOHOMISH POD E-4 WIRING DIAGRAMS LANE TO MERGE ONTO I-5 N TOWARD VANCOUVER B C.USE THE RIGHT 2 LANES TO TAKE EXIT 192 FOR 41ST STREET E.TAKE S 3RD AVE TO 39TH , <br /> 423-783-1000 E-5 ELECTRICAL NOTES ST.TURN RIGHT ONTO 41ST ST.TURN LEFT AT THE 1ST CROSS STREET ONTO S 3RD AVE.TURN RIGHT ONTO SMITH AVE TURN LEFT AT THE 1ST <br /> CROSS STREET ONTO 39TH ST.DESTINATION WILL BE ON THE RIGHT <br /> TELCO PROVIDER VERIZON G-1 GROUNDING DETAILS <br /> 1(800)922-0204 G-2 GROUNDING DETAILS <br /> SIGNATURES PROJECT DESCRIPTION APPLICABLE CODES/REFERENCE <br /> THE PURPOSE OF THIS PROJECT IS TO ENHANCE DOCUMENTS <br /> TEAM <br /> APPROVAL SIGNATURE DATE BROADBAND CONNECTIVITY AND CAPACITY TO THE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN <br /> PROJECT <br /> EXISTING ELIGIBLE WIRELESS FACILITY. ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS <br /> PROJECT MGR TOWER SCOPE OF WORK: <br /> ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.NOTHING IN THESE A.O. j S' <br /> A&E FIRM: GPD GROUP,PROFESSIONAL CORPORATION •REMOVE(3)ANTENNAS <br /> PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE .�S„LI*N'1.11,,,, ,:s,, <br /> ��N� :_, . ci <br /> 520 S.MAIN STREET,SUITE 2531 T-MOBILE RF ENGINEER •REMOVE(6)RRUS CODES: �i N <br /> AKRON,OH 44311 •REMOVE(3) I TMAs � s <br /> •REMOVE(1)HCS 1.0 COVP CODE TYPE CODE 4ssE9 <br /> BUILDING 2018 WASHINGTON STATE BUILDING CODE(20]8 IBC) A1r,Is-:MVO <br /> SITE ACQUISITION •REMOVE(1)HCS 1.0 HYBRID CABLE(1-3/5") , 3, , <br /> CROWN CASTLE 1505 W'ESTLAKE AVE N,STE 800 •INSTALL(3)ANTENNAS MECHANICAL 2018 WASHINGTON STATE MECHANICAL CODE(2018 IMC) .AJNM.cN. <br /> CONTACTS:SA INC.DISTRICT SEATTLE,WA 98109 •INSTALL(3)RRUS FT FCTRICAL 2020 WASHINGTON STATE EI.FCTRICAL SAFETY • <br /> CONSTRUCTION MGR STANDARDS(2020 NEC) 021255 11/25/2021 <br /> TALISSA FUGATE-PROJECT MANAGER •INSTALL(2)HCS 2.0 PENDANTS Ol21 1 <br /> (602)845-1719 1 <br /> SITE OWNER •INSTALL(2)HCS 2.0 HYBRID CABLES(1-1/2") <br /> PAUL LONG-CONSTRUCTION MANAGER GROUND SCOPE OF WORK: REFERENCE DOCUMENTS: <br /> T-MOBILE DEVELOPMENT MGR •REMOVE(1)SSC CABINET STRUCTURAL ANALYSIS: B+T GROUP <br /> COARSE BASS-A&E SPECIALIST •REMOVE(2)FCOA CABINETS DATED: 01/15/2021 <br /> CORRIE.BASS@CROWNCASTLE.COM •REMOVE(2)HCS 1.0 COVP MOUNT ANALYSIS: PENDING <br /> (770)375-4928 T-MOBILE CONSTRUCTION MGR •RELOCATE SYSTEM/RADIO MODULES DATED: <br /> •RELOCATE AIRSCALE EQUIPMENT INTO NEW HPL3 <br /> T-MOBILE OPS MGR •INSTALL(1)NEW HPL3 SSC W/BATTERY CABINET REDS REVISION: 5 coM SEAL <br /> NOTE ••INSTALL(3)HCS 2.0 JUNCTION BOXES DATED: 12/17/2020 IT IS A VIOL TION OF FOR ANY PERSON, <br /> PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN •INSTALL(1)FIBER CUBE CABINET UNLESS TFIHYARE-1CT OF <br /> LAWRANY PERSON, <br /> ,ON <br /> NOC AT(800)788-7011&CROWN CONSTRUCTION MANAGER. T-MOBILE REGULATORY REVIEW ORDER ID: 534496 _-. OF A LICENSED PROFESSIONAL ENGINEER, <br /> REVISION: 0 TO ALTER THIS DOCUMENT. <br /> CALL WASHINGTON ONE CALL ffiadiT-MOBILE PROJECT MGR <br /> SHEET NUMBER: REVISION: <br /> (���` �'/-�` T-MOBILE PERMITTING T- 1O <br /> 800 424-5555CALL 3 WORKING DAYS I � ALLDRAWL^1GSCAMAWFDHEREINAREFORMAI1.11FORPUILSIZE.CONTRACTORSHALL THE PARTIES ABOVE HERBBI'APPROVE AND ACCEPT'IHESB DOCUMENTS AND ALTHORIZE THE CONTRACTORTO PROCEED VERIFY ALL PLA\S AND EXISTING DIMENSIONS AND CONDI'IiONS ON THEJOB SITE AND SHALL <br /> BEFORE YOU DIGI WITH THE CONSTRUCTION DESCRIBED HEREIN.ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE L0,41 IMMEDLSTELI PROCEEDINGOTIFY EENGIITH ER INK WWRBPNGOF F)NY RESPONSIBLE CIES BEFORE ` <br /> BUILDING DEPARTMENI'AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. <br />