Laserfiche WebLink
Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: Bank of America Ext.Lighting Renov.,Everett,WA. Date 3/4/2020 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> NA tern 3 rooms control of all installed luminaires and switched receptacles in <br /> guest room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy <br /> NA Rem 4 lighting control for supplemental task lighting,including under-shelf or <br /> under-cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications, <br /> include sq.ft.area of each lighting control zone; <br /> C405.2.5- Lighting for non- Indicate on plans that non-visual lighting are controlled <br /> NA Rem 5 visual applications independently from both general area lighting and other lighting <br /> applications within the same space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Indicate on plans that lighting equipment for sale or <br /> Lighting equipment demonstration are controlled independently from both general <br /> C405.2.5- area lighting and other lighting applications within the same <br /> NA Rem 6 for sale or space; <br /> demonstration p <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Identify on plans egress fixtures that function as both normal <br /> and emergency means of egress illumination; <br /> Provide calculation of lighting power density of total egress <br /> NA C405.2.5- Means of egress lighting; <br /> Rem 7 lighting If total egress lighting power density is greater than 0.02 W/sq. <br /> ft.,indicate on plans egress fixtures requiring automatic shut-off <br /> during unoccupied periods; <br /> Indicate method of automatic shut-off control <br /> Indicate on exterior lighting plans and fixture schedules the <br /> automatic lighting control method,control sequence,and LU-1 <br /> locations served; <br /> For building facade and landscape lighting,indicate automatic <br /> Exterior lighting controls shut off lighting as a function of dawn/dusk and fixed LU-1 <br /> No C405.2.7 controls opening/closing time; <br /> For all other exterior lighting,indicate automatic controls shut off <br /> lighting as afunction of available daylight;include control <br /> sequence that also reduces lighting power by at least 30 <br /> between 12am-6am,or from 1 hour after closing to 1 hour <br /> before opening,or based upon motion sensor <br /> Exterior building For building grounds fixtures greater than 100 watts,indicate on <br /> No C405.5.1 grounds lighting plans whether fixtures have efficacy greater than 80 lumens or; <br /> controls are controlled by motion sensor,or are exempt lighting per <br /> C405.5.2 <br /> Area controls- Indicate location(s)of master control switch(es)intended to <br /> C405.2.5 Master control control multiple independent switches;circuit breaker may not <br /> NA (listed after be used as a master control switch; <br /> C405.2.7) switches and circuit Verify that no 20 amp circuit controlled by a single switch or <br /> power limit <br /> automatic control is loaded beyond 80% <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION-ENHANCED DIGITAL LIGHTING CONTROLS <br /> To comply with additional efficiency package option,indicate on <br /> plans all interior lighting fixtures that are individually addressed <br /> Enhanced digital and provided with continuous dimming,or exception taken; <br /> NA C406.4 lighting controls <br /> 9 9 Include calculation of percent total installed interior lighting <br /> power that is configured with required enhanced lighting control <br /> functions(min 90%to comply with additional efficiency package <br /> option) <br />