Laserfiche WebLink
I <br /> Exterior Lighting LTG-EXT <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: Bank of America Ext.Lighting Renov.,Everett,WA. Date 3/4/2020 <br /> Exterior Lighting a Zone iQ Zone e 3 Zone 4 For Building Department Use <br /> Zone Exterior Lighting Zone selection required to enable LTG-EXT form. <br /> Zones are defined in Table C405.5.2(1)and specified by the <br /> Calculation Area jut is�i`c co <br /> New construction Q Addition-stand along Addition <br /> +existing <br /> 0 Alteration with<5111 Alteration with>_50%ext. User <br /> ext.wattage replaced wattage replaced Note <br /> Building Grounds I Efficacy>80 lumens/wt Exemption <br /> Applies to individual <br /> luminaires>100 Watts C Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage NO'h' Base Site Allowance: 1300 <br /> Area(ft2),perimeter Allowed Watts Allowed Watts <br /> Tradable Surfaces Surface Description (If)or#of items per ft2 or per If x ft2(or x If)NOTE 2 <br /> Uncovered Parking and drives Asphalt 40368 0.10 W/ft2 4037 <br /> Total Allowed Tradable+Site Allowance Watts: 5337 <br /> Tradable Proposed Lighting Wattage NOTES <br /> Number of Watts per Watts <br /> Tradable Surface Fixture Description NOTE 4,5 Fixtures Fixture NOTE 6 Proposed <br /> Uncovered Parking and drives UBO1 Canopy Mount Fixture 3 20 60 <br /> _Uncovered Parking and drives UBO2 Canopy Mount Fixture 1 20 20 <br /> Uncovered Parking and drives UDX1 Canopy Mount Fixture 5 11 55 <br /> Uncovered Parking and drives UEM1 Canopy Mount Fixture 5 32 160 <br /> Uncovered Parking and drives UU1 Pole Mount Fixture 2 238 476 <br /> Uncovered Parking and drives UU2 Pole Mount Fixture 1 120 120 <br /> Uncovered Parking and drives UU3 Pole Mount Fixture 1 80 80 <br /> Uncovered Parking and drives UU4 Pole Mount Fixture 4 120 480 <br /> Uncovered Parking and drives UU5 Pole Mount Fixture 2 238 476 <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 1927 <br /> watts plus the base site allowance. Any base site allowance not needed to <br /> make tradable watts comply can be applied to individual non-tradable <br /> Non-Tradable Maximum Allowed Lighting Wattage'""" Site Allowance Remaining: 1300 <br /> Area(ft2),perimeter Allowed Watts Allowed Watts <br /> Non-Tradable Surfaces Surface Description (If)or#of items per ft2,If or item x ft2(or x If)NOTE 2 <br /> Non-Tradable Proposed Lighting Wattage NOTE3,7 <br /> Number of Watts per Watts <br /> Non-Tradable Surface Fixture Description NOTE 4,5 Fixtures Fixture NOTE 6 Proposed <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Non-Tradable Watts Exceeding LPA: 0 <br /> surface unless the total excess watts for all non-tradable surfaces are less than <br /> the remaining site allowance. Remaining Site Allowance: 1300 <br /> Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br /> Note 1-List all exterior surfaces per Table C405.5.2(2)that occur in the project scope.Select exterior surface categories from drop down menu <br /> Note 2-Unlit Message-Enter lighting fixture information for this surface in Proposed Lighting Wattage table to generate Lighting Power Allowa <br /> Note 3-List all proposed lighting fixtures including existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type,number of lamps in the fixture,and ballast type(if applicable). <br /> 2 <br />