Simple Heatina Svstem Size: Washinaton State <br />0 <br />Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, <br />some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension <br />Program at (360) 956-2042 for assistance. <br />Project Information Contact Information <br />DANIEL AND ESTERA IANOS KENT VICARY <br />7130 HIGHLAND DRIVE 16225 SE 42ND PLACE <br />EVERETT BELLEVUE WA. 98006 <br />Heating System Type: O All Other Systems O Heat Pump <br />To see detailed instructions for each section, place your cursor on the word 'Instructions". <br />Design Temperature <br />Design Temperature Difference (AT) 47 <br />Everett IC AT = Indoor (70 degrees) - Outdoor Design Temp <br />Area of Building <br />Conditioned Floor Area <br />Conditioned Floor Area (sq ft) <br />1,229 <br />Average Ceiling Height <br />Conditioned Volume <br />Average Ceiling Height (ft) <br />9.0 11,061 <br />Glazing and Doors <br />U-Factor X Area = <br />UA <br />U-0.30 <br />. <br />0.300 132 <br />39.60 <br />Skylights <br />U-Factor X Area = <br />UA <br />0.50 <br />Insulation <br />Attic <br />U-Factor X Area = <br />UA <br />R49 <br />1 0.026 1,229 <br />31.95 <br />Single Rafter or Joist Vaulted Ceilings <br />U-Factor X Area <br />UA <br />- Select R-Value,, <br />No Selection <br />--- <br />Above Grade Walls (see Figure t) <br />U-Factor X Area <br />UA <br />R-21 Intermediate <br />0.056 993 <br />55.61 <br />Floors <br />__.___J <br />U-Factor X Area <br />UA <br />R-38 <br />0.025 1,229 <br />30.73 <br />Below Grade Walls (see Figure 1) <br />U-Factor X Area <br />UA <br />Select R-value <br />. <br />No selection <br />--- <br />Slab Below Grade (see Figure 1) <br />F-Factor X Length <br />UA <br />Select conditioning <br />. <br />No selection l I <br />--- <br />Slab on Grade (see Figure 1.) <br />F-Factor X Length <br />UA <br />Select R-Value <br />. <br />No selection <br />--- <br />Location of Ducts <br />— — <br />— -- <br />Duct Leakage Coefficient <br />Unconditioned Space <br />1.10 <br />Sum of UA <br />157.89 <br />Envelope Heat Load <br />7,421 <br />Btu / Hour <br />Figure 1. <br />sumofuAXAT <br />Air Leakage Heat Load <br />5,615 <br />Btu / Hour <br />VolumeX 0.6XATX.018 <br />Above Grade <br />Building Design Heat Load <br />13,035 <br />Btu/Hour <br />Air Leakage + Envelope Heat Loss <br />Building and Duct Heat Load <br />14,339 <br />Btu/Hour <br />Ducts in unconditioned space: Sum of Building Heat Loss X 1. 10 <br />Ducts in conditioned space: Sum of Building Heat Loss X 1 <br />Maximum Heat Equipment Output <br />17,923 <br />Btu / Hour <br />Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br />Building and Duct Heat Loss X 1.25 for Heat Pump <br />(07101113) <br />